The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Sifa Muhimu:

FireAngel SW1-R Smoke Alarm front view

Kielelezo 1: Mbele view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Taarifa Muhimu za Usalama

Please read all instructions carefully before installation and operation. Keep this manual for future reference.

FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Yaliyomo kwenye Kifurushi

Thibitisha kwamba vitu vyote vipo na havijaharibika unapofungua kifurushi:

4. Mwongozo wa Ufungaji

Muhimu: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Hatua za Kusakinisha Mapema:

  1. Chagua Mahali: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Ondoa Nguvu: Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Sakinisha Betri ya Hifadhi Nakala: Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Alama za Kuchimba Visima: Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. Chimba Mashimo: Drill holes at the marked points and insert the rawl plugs.
  3. Bamba la Msingi la Mlima: Secure the base plate to the ceiling using the provided screws.
  4. Unganisha Wiring: Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Angalia Baada ya Usakinishaji:

  1. Rejesha Nguvu: Turn the mains electricity supply back on.
  2. Kengele ya Jaribio: Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Maagizo ya Uendeshaji

5.1. Uendeshaji wa Kawaida:

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. Matengenezo

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Utatuzi wa shida

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

TatizoSababu inayowezekanaSuluhisho
Alarm chirps intermittentlyLow 9V backup battery.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Dust or debris in the sensing chamber; high humidity; cooking fumes; steam.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
Kengele haisikiki wakati wa jaribioNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Maelezo ya kiufundi

Nambari ya MfanoSW1-R
Aina ya SensorOptical (Photoelectric)
Chanzo cha NguvuMains Powered (230V AC) with 9V DC Battery Backup
Sauti ya Kengele85dB kwa mita 3
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Vipimo vya Bidhaa (D x W x H)4.2D x 12.6W x Sentimita 12.6H
Uzito wa KipengeeGramu 220
Joto la UendeshajiRefer to product packaging for specific range
Aina ya unyevuRefer to product packaging for specific range
ViwangoEN 14604: 2005
UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Udhamini na Usaidizi wa Wateja

9.1. Taarifa ya Udhamini:

The FireAngel SW1-R Mains Smoke Alarm comes with a dhamana ya mwaka 5 kuanzia tarehe ya ununuzi. Udhamini huu unashughulikia kasoro katika nyenzo na utengenezaji chini ya matumizi ya kawaida. Tafadhali hifadhi uthibitisho wako wa ununuzi kwa madai ya udhamini.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Usaidizi kwa Wateja:

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official webtovuti au kifungashio cha bidhaa kwa maelezo ya mawasiliano ya kisasa zaidi.

Webtovuti: www.fireangel.co.uk (Kutampkiungo, kiunga halisi kinaweza kutofautiana kulingana na mkoa)

Nyaraka Zinazohusiana - SW1-R

Kablaview FireAngel HW1 Mains Powered Heat Alarm User Manual
Comprehensive user manual for the FireAngel HW1 Mains Powered Heat Alarm with 9V battery backup. Includes installation, positioning, silencing features, interconnecting options, maintenance, troubleshooting, and warranty information.
Kablaview FireAngel Smoke & Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
Comprehensive user manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Covers installation, maintenance, troubleshooting, warranty, and disposal.
Kablaview FireAngel ST-625-INT Smoke Alarm User Manual
Comprehensive user manual for the FireAngel ST-625-INT smoke alarm, covering installation, features, maintenance, and warranty. This guide provides essential safety information and operational instructions.
Kablaview Mwongozo wa Mtumiaji wa FireAngel FA6111, FA6115, FA6120 Kengele za Moshi na Kengele ya Joto ya FA6215
Mwongozo kamili wa mtumiaji wa kengele za moshi za macho za FireAngel FA6111, FA6115, FA6120 na kengele ya joto ya FA6215, unaohusu usakinishaji, matengenezo, utatuzi wa matatizo, vipengele kama vile Silence na Sleep Easy, udhamini, na utupaji.
Kablaview Mwongozo wa Mtumiaji wa Alarm ya FireAngel SCB10 na Mwongozo wa Mtumiaji wa Alarm ya Moshi ya Monoksidi ya Carbon
Mwongozo wa mtumiaji wa FireAngel SCB10, kengele mchanganyiko ya moshi na monoksidi ya kaboni, ukitoa maagizo ya kina kuhusu usakinishaji, uendeshaji, matengenezo na usalama kwa matumizi ya makazi.
Kablaview Mwongozo wa Mtumiaji wa FireAngel FA6611, FA6615, FA6620 Moshi na FA6720 Kengele ya Joto
Mwongozo wa mtumiaji wa kengele za moshi za macho za FireAngel FA6611, FA6615, FA6620 na kengele ya joto ya FA6720. Inajumuisha usakinishaji, uwekaji, matengenezo, utatuzi wa matatizo, udhamini, na taarifa za utupaji.