Utangulizi
The GODIYMODULES Precision Voltage Reference Module is designed for accurate voltage and resistance calibration. It features low-temperature drift components and is powered via a Type-C 5V port, eliminating the need for a battery. This module provides five distinct voltage reference levels and five resistance reference levels, making it suitable for verifying the accuracy and linearity of digital multimeters.
Bidhaa Imeishaview

Kielelezo cha 1: Juu chini view of the GODIYMODULES Precision Voltage Reference Module. This image shows the overall layout of the module, including the Type-C power input, DIP switches for selecting voltage, and output terminals.
The module incorporates an EMI filter for a cleaner power supply. It includes a green LED to indicate power status. The compact design (85x55x25mm) makes it convenient for various applications.
Kuanzisha na Muunganisho
- Ugavi wa Nguvu: Connect a 5V Type-C power source (0.5A minimum) to the Type-C port on the module. The green LED will illuminate to indicate power.
- Muunganisho wa Pato: Use appropriate test leads to connect your multimeter or device under test to the red (+) and black (-) output terminals on the module.
- Mazingira: For optimal accuracy, especially when verifying 4 1/2 digit multimeters, ensure the working environment maintains a stable temperature (16-30℃) and humidity (RH≤70%). Avoid direct airflow from air conditioners, which can introduce errors.

Kielelezo cha 2: Karibu-up view of the module showing the Type-C power input and the DIP switches for selecting reference values.
Maagizo ya Uendeshaji
Kuchagua Voltage Marejeo
The module provides five voltage reference levels: 1.24V, 2.5V, 5V, 7.5V, and 10V. These are selected using the DIP switches labeled 1 to 5. Each switch corresponds to a specific voltagkiwango.
- Badili 1: 1.24V
- Badili 2: 2.5V
- Badili 3: 5V
- Badili 4: 7.5V
- Badili 5: 10V
Caution: Only one DIP switch for voltage selection should be in the "ON" position at any given time. Activating multiple voltage switches simultaneously is not permitted and may lead to incorrect readings or module damage.
Selecting Resistance Reference
The module provides five fixed resistance reference levels: 10Ω, 100Ω, 1KΩ, 10KΩ, and 100KΩ. These are available at dedicated terminals on the board. To measure a specific resistance, connect your multimeter to the corresponding resistance terminals.

Kielelezo cha 3: View of the module highlighting the fixed resistance output terminals (10R, 100R, 1K, 10K, 100K).
Usage for Multimeter Calibration
- 3 1/2 Digit Multimeters: The module can be used to verify the accuracy and linearity of handheld 3 1/2 digit digital multimeters.
- 4 1/2 Digit Multimeters: For 4 1/2 digit digital multimeters, it is crucial to maintain the same temperature and humidity conditions as specified in the multimeter's data sheet for accurate verification.
Matengenezo
- Kusafisha: Weka moduli safi na isiyo na vumbi na uchafu. Tumia kitambaa laini na kikavu kwa kusafisha.
- Hifadhi: Store the module in a dry environment, away from extreme temperatures and humidity.
- Kushughulikia: Handle the module with care to avoid physical damage to components or connections.
Kutatua matatizo
- No Power Indication (Green LED Off):
- Ensure the Type-C power cable is securely connected.
- Verify that the 5V Type-C power source is functional and provides at least 0.5A.
- Vol isiyo sahihitagPato:
- Check that only one voltage selection DIP switch is in the "ON" position.
- Ensure proper connection to the multimeter.
- Verify environmental conditions (temperature, humidity) for sensitive measurements.
- Usomaji usio thabiti:
- Operate in a low airflow environment to prevent temperature fluctuations.
- Avoid direct cold wind from air conditioners.
Vipimo
| Kipengele | Vipimo |
|---|---|
| Jina la Bidhaa | Voltage Reference Module |
| Chapa | GODIYMODULES |
| Ugavi wa Nguvu | Type-C 5V port, 0.5A |
| Matumizi ya Nguvu isiyo na mzigo | 45mA |
| Kiashiria cha Nguvu | Taa ya LED ya kijani |
| Rejea Voltage Ngazi | 1.24V, 2.5V, 5V, 7.5V, 10V (5 levels) |
| Reference Resistance Levels | 10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ (5 levels) |
| Resistor Material | 0.1% Metal film copper feet & TCR: 25PPM |
| Dimensions (Clear Box Size) | 85mm x 55mm x 25mm |
| Uzito Net | 34g |
| Mazingira ya Kazi | 16-30℃, RH≤70% |
Rasilimali za Ziada
For a visual demonstration of a voltage reference module (note: this video may feature a similar but not identical product), please refer to the video below:
Video ya 1: Demonstration of a Voltage Reference Module. This video provides a general overview of how a voltage reference module might be used, including handling and basic operation. While the module shown may differ slightly from the GODIYMODULES model, it illustrates the general principles of such devices.
Udhamini na Msaada