GODIYMODULES Voltage Reference Module

GODIYMODULES Precision Voltage Reference Module User Manual

Mfano: Voltage Reference Module

Utangulizi

The GODIYMODULES Precision Voltage Reference Module is designed for accurate voltage and resistance calibration. It features low-temperature drift components and is powered via a Type-C 5V port, eliminating the need for a battery. This module provides five distinct voltage reference levels and five resistance reference levels, making it suitable for verifying the accuracy and linearity of digital multimeters.

Bidhaa Imeishaview

GODIYMODULES Precision Voltage Reference Module, top-down view

Kielelezo cha 1: Juu chini view of the GODIYMODULES Precision Voltage Reference Module. This image shows the overall layout of the module, including the Type-C power input, DIP switches for selecting voltage, and output terminals.

The module incorporates an EMI filter for a cleaner power supply. It includes a green LED to indicate power status. The compact design (85x55x25mm) makes it convenient for various applications.

Kuanzisha na Muunganisho

  1. Ugavi wa Nguvu: Connect a 5V Type-C power source (0.5A minimum) to the Type-C port on the module. The green LED will illuminate to indicate power.
  2. Muunganisho wa Pato: Use appropriate test leads to connect your multimeter or device under test to the red (+) and black (-) output terminals on the module.
  3. Mazingira: For optimal accuracy, especially when verifying 4 1/2 digit multimeters, ensure the working environment maintains a stable temperature (16-30℃) and humidity (RH≤70%). Avoid direct airflow from air conditioners, which can introduce errors.
GODIYMODULES Precision Voltage Reference Module with Type-C port and DIP switches

Kielelezo cha 2: Karibu-up view of the module showing the Type-C power input and the DIP switches for selecting reference values.

Maagizo ya Uendeshaji

Kuchagua Voltage Marejeo

The module provides five voltage reference levels: 1.24V, 2.5V, 5V, 7.5V, and 10V. These are selected using the DIP switches labeled 1 to 5. Each switch corresponds to a specific voltagkiwango.

  • Badili 1: 1.24V
  • Badili 2: 2.5V
  • Badili 3: 5V
  • Badili 4: 7.5V
  • Badili 5: 10V

Caution: Only one DIP switch for voltage selection should be in the "ON" position at any given time. Activating multiple voltage switches simultaneously is not permitted and may lead to incorrect readings or module damage.

Selecting Resistance Reference

The module provides five fixed resistance reference levels: 10Ω, 100Ω, 1KΩ, 10KΩ, and 100KΩ. These are available at dedicated terminals on the board. To measure a specific resistance, connect your multimeter to the corresponding resistance terminals.

GODIYMODULES Precision Voltage Reference Module showing resistance outputs

Kielelezo cha 3: View of the module highlighting the fixed resistance output terminals (10R, 100R, 1K, 10K, 100K).

Usage for Multimeter Calibration

  • 3 1/2 Digit Multimeters: The module can be used to verify the accuracy and linearity of handheld 3 1/2 digit digital multimeters.
  • 4 1/2 Digit Multimeters: For 4 1/2 digit digital multimeters, it is crucial to maintain the same temperature and humidity conditions as specified in the multimeter's data sheet for accurate verification.

Matengenezo

  • Kusafisha: Weka moduli safi na isiyo na vumbi na uchafu. Tumia kitambaa laini na kikavu kwa kusafisha.
  • Hifadhi: Store the module in a dry environment, away from extreme temperatures and humidity.
  • Kushughulikia: Handle the module with care to avoid physical damage to components or connections.

Kutatua matatizo

  • No Power Indication (Green LED Off):
    • Ensure the Type-C power cable is securely connected.
    • Verify that the 5V Type-C power source is functional and provides at least 0.5A.
  • Vol isiyo sahihitagPato:
    • Check that only one voltage selection DIP switch is in the "ON" position.
    • Ensure proper connection to the multimeter.
    • Verify environmental conditions (temperature, humidity) for sensitive measurements.
  • Usomaji usio thabiti:
    • Operate in a low airflow environment to prevent temperature fluctuations.
    • Avoid direct cold wind from air conditioners.

Vipimo

KipengeleVipimo
Jina la BidhaaVoltage Reference Module
ChapaGODIYMODULES
Ugavi wa NguvuType-C 5V port, 0.5A
Matumizi ya Nguvu isiyo na mzigo45mA
Kiashiria cha NguvuTaa ya LED ya kijani
Rejea Voltage Ngazi1.24V, 2.5V, 5V, 7.5V, 10V (5 levels)
Reference Resistance Levels10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ (5 levels)
Resistor Material0.1% Metal film copper feet & TCR: 25PPM
Dimensions (Clear Box Size)85mm x 55mm x 25mm
Uzito Net34g
Mazingira ya Kazi16-30℃, RH≤70%

Rasilimali za Ziada

For a visual demonstration of a voltage reference module (note: this video may feature a similar but not identical product), please refer to the video below:

Video ya 1: Demonstration of a Voltage Reference Module. This video provides a general overview of how a voltage reference module might be used, including handling and basic operation. While the module shown may differ slightly from the GODIYMODULES model, it illustrates the general principles of such devices.

Udhamini na Msaada

Specific warranty information for the GODIYMODULES Precision Voltage Reference Module is not provided in the product details. For warranty claims or technical support, please contact your retailer or the manufacturer directly.

Nyaraka Zinazohusiana - Voltage Reference Module

Kablaview WRYTECH PDVS 2 Mini v2 Precision Digital Voltage Chanzo Mwongozo wa Mtumiaji
Comprehensive user manual for the WRYTECH PDVS 2 Mini v2 handheld precision digital voltage source. Covers features, specifications, operation, settings, calibration, and troubleshooting for this versatile instrument used in research, development, and industry.
Kablaview ANENG M113 Digital Multimeter User Manual - Features, Specifications, and Operation
Comprehensive user manual for the ANENG M113 digital multimeter, covering its features, safety precautions, measurement methods, technical specifications, accuracy indicators, and maintenance procedures.
Kablaview ANENG M113 Pocket Digital Multimeter Instruction Manual
Comprehensive instruction manual for the ANENG M113 Pocket Digital Multimeter, covering safety precautions, instrument description, measurement methods, technical specifications, and maintenance.
Kablaview Mwongozo wa Mtumiaji wa Kipima-Mita cha Aina ya Kalamu ya Dijitali ya HABOTEST HT122
Mwongozo kamili wa mtumiaji wa Kipima-Kipimo cha Aina ya Kalamu ya Dijitali cha HABOTEST HT122. Jifunze kuhusu vipengele vyake vya usalama, hali za kiotomatiki na za mwongozo, ugunduzi wa NCV, kipimo cha mfuatano wa awamu, vipimo vya kiufundi, na matengenezo.
Kablaview Mwongozo wa Mtumiaji wa Kipima-Kidijitali cha Makazi cha UNI-T UT123/UT123D
Mwongozo kamili wa mtumiaji wa Multimita za Kidijitali za Makazi za UNI-T UT123 na UT123D, unaohusu vipengele, maagizo ya usalama, taratibu za uendeshaji, vipimo, na matengenezo.
Kablaview Mwongozo wa Mtumiaji wa Xhorse MK3 Digital Multimeter
Mwongozo wa mtumiaji wa Multimeter ya Dijiti ya Xhorse MK3, inayojumuisha vipengele vyake, uendeshaji, maonyo ya usalama, na vipimo vyake vya vipimo sahihi vya umeme.