1. Utangulizi
This manual provides essential information for the safe and effective installation, operation, and maintenance of your MARSTEK 10A 440V Latching Emergency Stop Button Switch. This device is designed for critical safety applications, offering a reliable "push to lock, turn to release" mechanism for immediate system shutdown. Its robust aluminum alloy construction and IP67 protection ensure durability and performance in various industrial environments.
2. Taarifa za Usalama
ONYO: Hatari ya mshtuko wa umeme. Ufungaji na matengenezo yanapaswa kufanywa na wafanyakazi waliohitimu pekee.
- Daima ondoa umeme kabla ya kusakinisha, kuunganisha waya, au kufanya matengenezo kwenye swichi.
- Hakikisha wiring zote zinatii misimbo ya umeme ya ndani na ya kitaifa.
- Verify the switch's voltage and current ratings are suitable for your application.
- The emergency stop function is critical. Regularly test the switch to ensure proper operation.
- Do not bypass or modify the emergency stop switch.
3. Yaliyomo kwenye Kifurushi
- Emergency Stop Push Button Switch (1 unit)
4. Bidhaa Imeishaview
The MARSTEK Emergency Stop Button Switch features a durable aluminum alloy construction and a clear, intuitive design for rapid emergency response. It is engineered for reliable performance in demanding conditions.

Kielelezo 1: Imekusanyika view of the MARSTEK Emergency Stop Button Switch.
Sifa Muhimu:
- Uimara wa Premium: Crafted from corrosion-resistant aluminum alloy with flame-retardant silver contacts.
- Reliable E-Stop Function: "Push to lock, turn to release" latching mechanism, 440V/10A with 1NO+1NC contacts.
- Uendeshaji laini: Optimized spring mechanism for quick response and resistance to deformation.
- Ulinzi wa IP67: Complete dust and waterproof sealing for harsh industrial environments.
- Maombi Mengi: Suitable for industrial machinery, medical equipment, vehicles, marine use, and home appliances.

Figure 2: Various perspectives of the Emergency Stop Button Switch.

Mchoro 3: Imevunjwa view showing the button and contact block.
5. Kuweka na Kuweka
The MARSTEK Emergency Stop Button Switch is designed for 22mm panel mounting. Follow these general steps for installation:
- Kuandaa Paneli: Drill a 22mm diameter hole in the desired mounting location on your control panel.
- Disassemble Switch: Separate the button actuator from the contact block by twisting or releasing the locking mechanism (refer to Figure 3).
- Mount Actuator: Insert the button actuator through the panel hole from the front. Secure it with the provided locking nut from the rear of the panel.
- Attach Contact Block: Reattach the contact block to the actuator, ensuring it clicks securely into place.
- Wiring: Connect your electrical circuits to the 1NO+1NC (Normally Open + Normally Closed) screw terminals on the contact block. Ensure correct polarity and secure connections. Refer to your system's electrical diagram for specific wiring requirements.
- Utendaji wa Mtihani: Before restoring power to the system, manually test the push-to-lock and turn-to-release actions of the button.

Figure 4: Dimensions for panel mounting.

Figure 5: Detail of silver alloy contacts for wiring.
6. Maagizo ya Uendeshaji
The MARSTEK Emergency Stop Button Switch operates with a simple and effective mechanism:
- Ili Kuamilisha (Simamisha): Firmly push the red button. It will latch into the depressed position, immediately breaking the circuit and initiating an emergency stop.
- To Deactivate (Release): Rotate the red button clockwise (following the arrows marked "PUSH STOP" and circular arrows on the button face). The button will spring back to its original position, restoring the circuit.
7. Matengenezo
Regular maintenance ensures the longevity and reliability of your emergency stop switch:
- Ukaguzi wa Visual: Periodically inspect the switch for any signs of physical damage, corrosion, or loose connections.
- Kusafisha: Clean the button and surrounding area with a soft, damp cloth. Avoid using abrasive cleaners or solvents that could damage the material or markings.
- Mtihani wa Utendaji: Regularly test the push-to-lock and turn-to-release mechanism to confirm smooth operation and proper latching/unlatching.
8. Utatuzi wa shida
If you encounter issues with your emergency stop switch, consider the following:
- Switch Not Activating: Ensure the button is fully depressed and latched. Check for any obstructions.
- Switch Not Releasing: Ensure the button is rotated fully clockwise. Check for any mechanical binding or damage.
- No Circuit Interruption/Restoration: Verify all wiring connections are secure and correct. Check the integrity of the contact block. Ensure power supply is present and correctly routed.
- Operesheni ya mara kwa mara: Inspect for loose wiring, damaged contacts, or excessive dirt/debris within the mechanism.
If problems persist, consult a qualified electrician or contact MARSTEK customer support.
9. Vipimo
| Vipimo | Thamani |
|---|---|
| Vipimo vya Bidhaa | inchi 2.86 x 1.71 x 1.57; Wakia 2.4 |
| Hali ya Uendeshaji | ON-OFF (Latching Push Button) |
| Ukadiriaji wa Sasa | 10 Amps |
| Uendeshaji Voltage | 440 Volts (as per product title, though specifications list 250V) |
| Aina ya Mawasiliano | 1 Kawaida Hufunguliwa (HAPANA) + 1 Kawaida Hufungwa (NC) |
| Aina ya kiunganishi | Clamp (Screw Terminals) |
| Chapa | MARSTEK |
| Badilisha Aina | Bonyeza Kitufe |
| Kituo | Parafujo |
| Nyenzo | Aluminum Alloy (Button), Stainless Steel (Internal components) |
| Ukadiriaji wa Ulinzi | IP67 (Vumbi na Haipitishi Maji) |
| Kipenyo cha Shimo la Kupanda | 22 mm |
Note: The product title indicates 440V, while the specifications list 250V. Please verify the exact operating voltage with the manufacturer or product labeling before use.

Figure 6: Visual representation of key product parameters.
10. Udhamini na Msaada
For warranty information, technical support, or any inquiries regarding your MARSTEK Emergency Stop Button Switch, please contact the manufacturer directly through their official channels. Keep your purchase receipt for warranty claims.