1. Utangulizi
This manual provides comprehensive instructions for the installation, operation, and maintenance of your TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.
Taarifa Muhimu za Usalama
- Ufungaji wa Kitaalamu Unahitajika: This system requires installation by a certified HVAC technician for optimal performance and safety. DIY installation is not recommended.
- Usalama wa Umeme: Ensure all electrical connections comply with local codes and standards. Disconnect power before any service or maintenance.
- Ushughulikiaji wa Jokofu: This system uses R-32 refrigerant. Only qualified personnel should handle refrigerant.
- Soma Maonyo Yote: Pay close attention to all warning labels on the unit and throughout this manual.
2. Bidhaa Imeishaview
The TOSOT 60,000 BTU (5 Ton) Ducted Central Air Conditioner Heat Pump System is an inverter split system designed for efficient heating and cooling. It features advanced technology for reliable operation in various climates.
Vipengee vilivyojumuishwa
- Kitengo cha Condenser ya Nje
- Indoor Air Handler Unit
- 50-foot Copper Line Set
- Installation Kit (includes sealing gum, wall cap, wall sleeve, tapes, and user manual)

Figure 2.1: Complete TOSOT Central Air Conditioner Heat Pump System with included components.
Video 2.1: Zaidiview of the TOSOT Central Air Conditioner Heat Pump System, highlighting its main units and features.
3. Sifa Muhimu
3.1. UltraCool & UltraHeat Technology
This system provides efficient heating and cooling across a wide temperature range, from -22℉ to 130℉, ensuring comfort in extreme conditions.

Figure 3.1: Performance capabilities of UltraCool and UltraHeat technology in varying outdoor temperatures.
3.2. Self-Developed Inverter Compressor
The system utilizes a triple-cylinder two-stage rotary compressor with enhanced vapor injection technology. This design optimizes low-temperature heating, maintaining 100% heating capacity at -5℉ and 100% cooling performance at 115℉.

Figure 3.2: Details of the DC Inverter Compressor, highlighting its efficiency and low noise operation.
Video 3.1: Demonstration of the Central AC Heat Pump with Inverter Technology, showcasing its operational benefits.
Video 3.2: Visual explanation of the Central AC Split System Heat Pump with Inverter, detailing its components and function.
3.3. Ufanisi wa Nishati
With ratings up to 18.5 SEER2 and 10.5 HSPF2, this system offers significant energy savings. Inverter technology can provide up to 30% more energy savings compared to non-inverter systems with the same SEER2 rating. It is Energy Star certified and may qualify for federal tax credits.

Figure 3.3: Energy Star and other certifications for the TOSOT Heat Pump System.
3.4. Upgraded Condenser Design
The slim design of the outdoor condenser unit requires less space, making it suitable for constricted areas. Its side discharge design minimizes debris accumulation and keeps noise levels below 63 dB.

Figure 3.4: Comparison of TOSOT APEX Condenser design with traditional condensers.
3.5. High Static Pressure Design
The TOSOT unitary central AC adapts to actual static pressure, making it ideal for areas requiring long-distance airflow. It offers eight adjustable fan speeds to meet the needs of various living spaces.

Figure 3.5: Benefits of the High Static Pressure Fan for optimized airflow.
3.6. Multipositional Air Handler
The indoor air handler unit can be installed horizontally or vertically, providing flexible installation options for basements, attics, and both residential and commercial spaces.

Figure 3.6: Flexible installation configurations for the indoor air handler.
4. Vipimo
| Kipengele | Vipimo |
|---|---|
| Chapa | TOSOT |
| Mfano | 60,00BTU-50ft |
| Uwezo | Tani 5 (BTU 60,000) |
| Nguvu ya Kupoa | 53,000 Vitengo vya joto vya Uingereza |
| Uwiano wa Ufanisi wa Nishati kwa Msimu (SEER2) | 18.5 |
| Kipengele cha Utendaji wa Msimu wa Kupasha Joto (HSPF2) | 10.5 |
| Kiwango cha Kelele | 63 Decibels (Outdoor Condenser) |
| Kiwango cha Joto la Uendeshaji | -22℉ hadi 130℉ |
| Aina ya Compressor | Inverter, Triple-Cylinder Two-StagRotary |
| Jokofu | R-32 |
| Voltage | 230 Volts |
| Wattage | 16,120 watts |
| Outdoor Condenser Dimensions (D x W x H) | 13.4" x 35.4" x 49.6" |
| Indoor Air Handler Dimensions (D x W x H) | 21.3" x 24.8" x 52.0" |
| Uzito wa Kipengee | Pauni 241 |
| Ufunikaji wa Eneo la Sakafu | Hadi futi za mraba 3000 |
| Urefu wa Kuweka Mstari | 50 feet (Copper) |
| Vyeti | Energy Star, ETL, AHRI Certified |
5. Kuweka na Kuweka
The TOSOT Central Air Conditioner Heat Pump System is a complex appliance that requires professional installation. Attempting to install this unit without proper certification and tools can lead to serious injury, property damage, and void the product warranty.
5.1. Mazingatio ya Kabla ya Ufungaji
- Mahali: Choose appropriate locations for both the outdoor condenser and indoor air handler, considering airflow, noise, and accessibility for maintenance. The multipositional air handler allows for vertical or horizontal installation.
- Mahitaji ya umeme: Ensure the electrical supply meets the 230V requirement and is properly grounded.
- Uendeshaji wa mabomba: Verify existing ductwork is compatible and in good condition for efficient air distribution. The high static pressure design is suitable for long-distance airflow.
- Thermostat: This system is compatible with universal 24V thermostats (not included).

Figure 5.1: Universal 24V thermostat compatibility.
5.2. Professional Installation Steps (Summary)
- Mount the indoor air handler in the chosen vertical or horizontal position.
- Position the outdoor condenser unit, ensuring adequate clearance for airflow.
- Connect the 50-foot copper line set between the indoor and outdoor units.
- Perform all necessary electrical wiring connections.
- Connect the thermostat wiring.
- Evacuate the refrigerant lines and charge the system with R-32 refrigerant.
- Test the system for proper operation, including airflow and temperature control.

Figure 5.2: Professional installation is crucial for system integrity and safety.
6. Maagizo ya Uendeshaji
Once professionally installed, your TOSOT Heat Pump System is controlled via a compatible 24V thermostat. Refer to your thermostat's user manual for specific programming and operation details.
6.1. Operesheni ya Msingi
- Washa/Zima: Use your thermostat to turn the system on or off.
- Uteuzi wa Hali: Select desired operating mode (Cool, Heat, Fan, Auto) on your thermostat.
- Mpangilio wa Halijoto: Rekebisha halijoto unayotaka kwa kutumia vidhibiti vya halijoto.
6.2. Marekebisho ya Kasi ya shabiki
The system features eight adjustable fan speeds. Your installer can configure these settings to optimize airflow and comfort for your specific ductwork and living space. Consult your installer or thermostat manual for how to adjust fan speeds if accessible to the user.
7. Matengenezo
Regular maintenance is essential to ensure the longevity and efficient operation of your TOSOT Heat Pump System. It is recommended to schedule annual professional maintenance.
7.1. Kubadilisha Kichujio
Regularly check and replace the air filter in your indoor air handler. A dirty filter restricts airflow and reduces efficiency. The recommended filter size is 20x23 inches, though some documentation may incorrectly state 20x20 inches. Verify the actual size of your installed filter.
7.2. Outdoor Condenser Cleaning
Keep the area around the outdoor condenser unit clear of debris, leaves, and vegetation to ensure proper airflow. The side discharge design helps minimize accumulation, but periodic inspection is still advised.
7.3. Huduma ya Kitaalam
Schedule annual maintenance with a certified HVAC technician. This includes checking refrigerant levels, inspecting electrical components, cleaning coils, and verifying overall system performance.
8. Utatuzi wa shida
If you experience issues with your system, perform the following basic checks before contacting a service technician:
- Hakuna Nguvu: Check the circuit breaker for the unit. Ensure the thermostat is set to the desired mode and temperature.
- Kupoeza/Kupasha Joto Kutosha: Verify the thermostat settings. Check if the air filter is clean. Ensure outdoor unit is free of obstructions.
- Kelele zisizo za kawaida: Minor operational noises are normal. If you hear loud or unusual sounds, contact a technician.
- Uvujaji wa Maji: Check the condensate drain line for blockages.
For any persistent issues or complex problems, contact a certified HVAC technician for diagnosis and repair.
9. Udhamini na Msaada
9.1. Taarifa za Udhamini
The TOSOT 60,000 BTU Ducted Central Air Conditioner Heat Pump System comes with a dhamana ya miaka mitano. Please retain your proof of purchase and installation records for warranty claims. The warranty covers defects in materials and workmanship under normal use and service.
For specific terms and conditions of the warranty, refer to the warranty card included with your product or contact TOSOT customer support.
9.2. Msaada kwa Wateja
For technical assistance, troubleshooting, or warranty inquiries, please contact TOSOT customer support:
- Webtovuti: [Insert TOSOT Support Webtovuti Hapa]
- Simu: [Insert TOSOT Support Phone Number Here]
- Barua pepe: [Insert TOSOT Support Email Here]
When contacting support, please have your model number (60,00BTU-50ft) and date of purchase readily available.