1. Utangulizi
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your TOSOT Cosmo Series 36,000 BTU Quad 4 Zone Mini Split AC with Heat Pump. Please read this manual thoroughly before installation and use, and retain it for future reference. This system is designed to provide individual temperature control across four distinct zones using a single outdoor unit and four 9,000 BTU indoor units.
2. Taarifa za Usalama
Maagizo Muhimu ya Usalama:
- Installation and maintenance must be performed by qualified, certified HVAC technicians in accordance with all local and national electrical and safety codes.
- Hakikisha usambazaji wa umeme unalingana na vipimo vya kitengo (230V).
- Usijaribu kurekebisha au kurekebisha kitengo mwenyewe. Wasiliana na wafanyikazi wa huduma waliohitimu.
- Kuweka msingi sahihi ni muhimu ili kuzuia mshtuko wa umeme.
- Hakikisha uingizaji hewa mzuri kuzunguka kitengo cha nje.
- Weka watoto na wanyama kipenzi mbali na kitengo cha nje wakati wa operesheni.
- Refrigerant handling requires specialized tools and training.
3. Yaliyomo kwenye Kifurushi
Verify that all components are present before beginning installation. Your TOSOT Cosmo Series system includes the following:
Indoor Unit Components (x4 sets)
- 1 x Sehemu ya Ndani
- 5 x Anchor ya Drywall
- 2 x Flare Nut
- 4 x Remote Holder Fixing Screw
- 5 x Mounting Plate Fixing Screw
- 2 x Betri ya AAA
- 1 x Remote Control Holder
- 1 x App Control Quick Guide
- 1 x Udhibiti wa Mbali
- 1 x Bamba la kupanda
- 1 x Insulation Sleeve
- 1 x 20 ft Signal Cable
Outdoor Unit Components (x1 set)
- 1 x Sehemu ya nje
- 1 x Drain Joint
- 1 x Mwongozo wa Mtumiaji
Installation Accessories (x2 sets)
- 1 set x Refrigerant Pipe (16.4 ft copper line set)
- 1 x Sealing Gum
- 2 x Mkanda
- 1 x Futa Hose
- 1 x Wall Sleeve

4. Kuweka na Kuweka
The TOSOT Cosmo Series Mini Split system requires professional installation. While designed for easier installation compared to central AC systems, specific HVAC and electrical knowledge is necessary. The system includes a 16.4-foot copper line set for each indoor unit, but the power cord is not included and must be sourced separately.
4.1 Key Installation Steps
- Mounting Indoor Units: Securely mount each of the four indoor units in their designated zones, ensuring proper clearance for airflow and maintenance.
- Uwekaji wa kitengo cha nje: Position the single outdoor unit on a stable, level surface, allowing adequate space for air circulation and service access.
- Muunganisho wa Seti ya Mstari wa Jokofu: Connect the provided copper line sets between each indoor unit and the outdoor unit. This step requires precise flaring, torqueing, and the use of Nylog sealant to prevent leaks.
- Wiring za Umeme: Connect the electrical wiring according to the wiring diagram provided in the detailed user manual. Ensure the correct voltage (230V) and breaker size (e.g., 40A) are used.
- Vacuuming the System: Evacuate the refrigerant lines to remove air and moisture. This is a critical step for system efficiency and longevity. A vacuum pump must be used to pull a deep vacuum for at least 30 minutes per line set, and the vacuum must hold for at least an hour to confirm no leaks.
- Kutolewa kwa Friji: Once the vacuum test is successful, carefully release the R32 refrigerant from the outdoor unit into the system.
- Muunganisho wa Mifereji ya maji: Ensure all indoor units have proper condensate drainage connected to prevent water leaks.


4.2 Taarifa za Friji
This system utilizes R32 refrigerant, which has a 67% lower Global Warming Potential (GWP) and requires a 30% lower refrigerant charge compared to R410A systems, contributing to environmental benefits.

5. Maagizo ya Uendeshaji
Your TOSOT Mini Split system offers versatile climate control for up to four zones, with individual temperature settings and operating modes.
5.1 Njia za Uendeshaji
The system supports the following modes:
- Kupoeza: Provides cooling to maintain desired room temperature.
- Inapokanzwa: Functions as a heat pump, providing warmth even in extreme cold conditions (down to -22°F).
- Shabiki: Huzunguka hewa bila inapokanzwa au baridi.
- Kuondoa unyevunyevu: Reduces humidity levels in the room.

5.2 Udhibiti wa Halijoto
Each indoor unit can be set to a desired temperature between 61°F and 86°F (16°C and 30°C) independently. The advanced inverter technology ensures stable temperatures and quiet operation.

5.3 Udhibiti wa Smart
Manage your system from anywhere using the Gree+ app on your smartphone. The system also supports voice control for hands-free adjustments. Each indoor unit comes with its own remote control for direct adjustments.

6. Matengenezo
Regular maintenance ensures optimal performance and longevity of your TOSOT Mini Split system.
6.1 Indoor Unit Maintenance
- Kusafisha Kichujio: Clean the air filters every 2-4 weeks, or more frequently depending on usage and air quality. Refer to the detailed user manual for instructions on how to remove and clean the filters.
- Kusafisha Coil: Periodically inspect and clean the indoor coil. This should ideally be done by a professional.
6.2 Matengenezo ya Sehemu za Nje
- Futa Uchafu: Keep the area around the outdoor unit clear of leaves, dirt, and other obstructions to ensure proper airflow.
- Kusafisha Coil: Clean the outdoor coil annually, or as needed, to remove accumulated dirt and debris. This can be done with a garden hose, but avoid high-pressure sprays.
- Ukaguzi wa mifereji ya maji: Ensure the drain pan and drain holes are clear to prevent water buildup.
7. Utatuzi wa shida
If you encounter issues with your system, refer to the following basic troubleshooting steps. For complex problems, contact a qualified HVAC technician.
7.1 Masuala ya Kawaida na Suluhu
- Kitengo Kisichowashwa: Angalia usambazaji wa umeme, kivunja mzunguko, na uhakikishe betri za udhibiti wa mbali zinafanya kazi.
- Kupoeza/Kupasha Joto Kutosha: Verify correct mode selection and temperature settings. Clean air filters. Ensure outdoor unit is not obstructed.
- Kelele zisizo za kawaida: Minor noises during operation are normal. If loud or unusual noises occur, contact a technician.
- Uvujaji wa Maji: Check indoor unit drainage hose for kinks or blockages. Ensure outdoor unit is level.
- Kidhibiti cha Mbali hakifanyi kazi: Replace batteries. Ensure no obstructions between remote and indoor unit.
8. Vipimo
Key technical specifications for the TOSOT Cosmo Series 36,000 BTU Quad 4 Zone Mini Split AC with Heat Pump (Model TST-MZ-M36-Q9999):
| Vipimo | Thamani |
|---|---|
| Chapa | TOSOT |
| Nambari ya Mfano | TST-MZ-M36-Q9999 |
| Aina ya Mfumo | Quad 4 Zone Mini Split AC with Heat Pump |
| Jumla ya Uwezo | 36,000 BTU (Tani 3) |
| Indoor Unit Capacity (each) | 9,000 BTU |
| Ukadiriaji wa SEER2 | 21 |
| Ukadiriaji wa HSPF2 | 10 |
| Voltage | 230 Volts |
| Vipimo vya Kitengo cha Nje (U x Upana x Urefu) | 40.2" x 16.8" x 32.5" |
| Uzito wa Kipengee | Pauni 339 |
| Kiwango cha Kelele (Kitengo cha Nje) | 63 decibels |
| Operating Temperature Range (Heating) | -22°F hadi 118°F |
| Aina ya jokofu | R32 |
| Vipengee vilivyojumuishwa | Remote, User Manual |
| Estimated Coverage Area | futi za mraba 1800 |


9. Udhamini na Msaada
TOSOT provides a five-year warranty for this product, ensuring peace of mind regarding your investment. For any service inquiries, technical support, or warranty claims, please contact TOSOT customer service. It is recommended to arrange installation only after receiving all parts of your order, as shipments may arrive in multiple packages or on pallets at different times.
For detailed support, refer to the contact information provided in the full user manual included with your product or visit the official TOSOT webtovuti.