1. Utangulizi
This manual provides detailed instructions for the assembly, installation, and operation of your TECMOJO 12U Open Frame Network Rack. Please read these instructions carefully before beginning assembly to ensure proper setup and safe use of the product. Retain this manual for future reference.
2. Bidhaa Imeishaview
The TECMOJO 12U Open Frame Network Rack is designed for organizing IT and AV equipment. It features a 4-post design, mobility with casters, and includes server shelves and mounting hardware for 19-inch network, audio, and video devices.
2.1 Sifa Muhimu
- Uwezo wa Kupakia: Constructed from durable cold-rolled steel, offering a load-bearing capacity of 260 lbs (floor-mounted).
- Uhamaji: Equipped with four casters for easy movement. Casters include brakes for stability.
- Included Shelves: Comes with two ventilated 1U server shelves.
- Muundo wa Kuzuia Kuteleza: Features anti-slip shelf stops to secure devices on shelves.
- Usimamizi wa Cable: Integrated grommet holes on the top panel for organized cable routing.
- Uwekaji Mbadala: Supports both standalone and wall-mounted configurations.
2.2 Vipengele vilivyojumuishwa
Hakikisha kwamba vipengele vyote vilivyoorodheshwa hapa chini vipo kabla ya kuanza kuunganisha:

Kielelezo 1: Vipengele vilivyojumuishwa
- 12U Open Frame Server Rack (main frame components)
- 1U 14-inch Rack Shelf x 2
- Shelf Stop x 4
- Rack Shelf Back Support x 4
- Caster x 4
- L Wrench x 1
- Kamba ya Velcro x 4
- Kiunga cha Kebo x 4
- 10-32 Screw x 25 (for equipment mounting)
- M5*30 Wall Mounting Screw x 4
- Mounting Hole Drilling Template x 1
3. Vipimo
| Sifa | Thamani |
|---|---|
| Mfano | 12U |
| Vipimo vya Bidhaa (D x W x H) | 20.2" x 20.5" x 21.0" (512mm x 520mm x 534mm) |
| Uzito wa Kipengee | Pauni 31.7 |
| Nyenzo | Chuma cha Aloi (Chuma Kilichoviringishwa Baridi) |
| Rangi | Nyeusi |
| Load Capacity (Floor-mounted) | Pauni 260 |
| Load Capacity (Wall-mounted) | Pauni 130 |
| Aina ya Rack | 4-Post Open Frame |

Mchoro 2: Vipimo vya Bidhaa
4. Kuweka na Kukusanya
Assembly typically requires one person and takes approximately 30-60 minutes. A power screwdriver is recommended for efficiency, though an L wrench is provided.
4.1 Hatua za Kusanyiko
- Fungua Vipengee: Carefully remove all parts from the packaging and verify against the 'Components Included' list.
- Kukusanya Fremu: Connect the side posts to the top and bottom frame sections using the provided hardware. Ensure all screws are tightened securely.
- Sakinisha Casters: Attach the four casters to the bottom frame. Ensure the casters with brakes are positioned for easy access.
- Sakinisha Rafu: Position the 1U ventilated shelves at desired heights within the rack. Secure them using the provided 10-32 screws.
- Attach Shelf Stops and Back Supports: Install the anti-slip shelf stops on the shelves to prevent equipment movement. Attach the rack shelf back supports for enhanced stability and load capacity.

Figure 3: Rack with Equipment, showing Anti-Slip Shelf Stops and Back Support
4.2 Uwekaji wa Ukuta (Si lazima)
For wall-mounted installations, use the included mounting hole drilling template and M5*30 wall mounting screws. Ensure the mounting surface can support the rack's weight and equipment (up to 130 lbs).

Figure 4: Wall Mounting Template and Option
5. Maagizo ya Uendeshaji
5.1 Installing Equipment
- Align your 19-inch rack-mountable equipment with the tapped holes on the rack posts.
- Use the provided 10-32 screws to secure equipment. Ensure equipment is evenly distributed to maintain stability.
- For non-rack-mountable equipment, place them on the ventilated shelves and use the anti-slip shelf stops to prevent movement.
5.2 Usimamizi wa Cable
Utilize the grommet holes on the top panel for routing cables. Use the included Velcro straps and cable ties to organize and secure cables, preventing strain and improving airflow.

Figure 5: Detailed Features: Grommet Holes, Tapped Holes, and Casters
5.3 Uhamaji na Uthabiti
- To move the rack, ensure all caster brakes are disengaged.
- When the rack is in its desired position, engage the caster brakes to prevent unintended movement.
6. Matengenezo
- Kusafisha: Wipe the rack surfaces with a soft, damp kitambaa. Epuka kusafisha abrasive ambayo inaweza kuharibu kumaliza.
- Ukaguzi: Periodically check all screws and connections to ensure they remain tight. Re-tighten as necessary.
- Usambazaji wa Mzigo: Ensure equipment weight is evenly distributed to maintain rack stability and prevent stress on components.
7. Utatuzi wa shida
- Kutokuwa na utulivu wa Rack: Ensure all frame screws are fully tightened. Verify that caster brakes are engaged when the rack is stationary. Check for uneven weight distribution of equipment.
- Difficulty Mounting Equipment: Ensure equipment is 19-inch rack-mountable. If holes do not align, verify the rack posts are correctly assembled and not warped. Some minor adjustments may be needed during initial setup.
- Sehemu Zinazokosekana: Refer to the 'Components Included' list. If parts are missing, contact Tecmojo customer support.
8. Udhamini na Msaada
For warranty information or technical support, please refer to the official Tecmojo webtovuti au wasiliana na idara yao ya huduma kwa wateja. Hifadhi risiti yako ya ununuzi kwa madai ya udhamini.