waveshare 4-CH RS485 TO POE ETH (B)

waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server (Model 4-CH RS485 TO POE ETH (B)) Instruction Manual

Mwongozo wa kina wa usanidi, uendeshaji, na matengenezo.

1. Utangulizi

The waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server, Model 4-CH RS485 TO POE ETH (B), is a multi-functional industrial device designed for data acquisition and IoT gateway applications. It features four independent RS485 channels, allowing for effective and isolated data transmission. This module integrates functionalities such as a serial server, Modbus gateway, MQTT gateway, and RS485 to JSON conversion, making it suitable for diverse industrial network environments. Its robust design includes power supply and signal isolation, along with comprehensive protection features, ensuring stable and reliable operation.

Video ya 1: Zaidiview of the waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server. This video demonstrates the device's key features and applications, highlighting its multi-functional capabilities and robust design for industrial use.

2. Yaliyomo kwenye Kifurushi

Baada ya kufungua, tafadhali thibitisha kuwa vitu vyote vifuatavyo vimejumuishwa:

  • 1x 4-CH RS485 TO POE ETH (B) Module
  • 1x Rail-mount buckle
  • 1 x Screwdriver
  • 1x Screws pack (4 screws)
Package contents of the waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server

Picha ya 1: Illustration of the waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server and its included accessories, such as the rail-mount buckle, screwdriver, and screws.

3. Features at a Glance

The 4-Ch RS485 to RJ45 Ethernet Serial Server offers a comprehensive set of features for industrial communication needs:

  • Independent RS485 Channels: Four RS485 channels operate independently, ensuring efficient and isolated data transmission without mutual interference.
  • Multi-functional Integration: Combines serial server, Modbus gateway, MQTT gateway, and RS485 to JSON functionalities.
  • Stable Power Input: Utilizes a screw terminal for reliable and stable power connection.
  • Kuweka Rahisi: Supports both wall-mount and rail-mount installations for quick deployment and expansion in industrial settings.
  • Industrial Isolation: Features power isolation and signal isolation for enhanced reliability and anti-interference.
  • PoE Ethernet Port: Includes a Power over Ethernet (PoE) enabled RJ45 port for simplified power and data connectivity (PoE version only).
  • Multi-Host Support: Designed to prevent crosstalk while communicating with multiple network devices.
  • Inaweza kusanidiwa: Inasaidia web browser configuration, DHCP, DNS, and device management functions library.
Key features of the waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server

Picha ya 2: Visual representation of the core features, including industrial isolation, rail-mount capability, Modbus gateway, 4-channel independent RS485, and multiple power supply methods.

4. Vipimo

Detailed technical specifications for the 4-CH RS485 TO POE ETH (B) module:

KategoriaVipimo
Aina ya BidhaaSeva ya mfululizo, Lango la Modbus, Lango la MQTT
Kazi ya MsingiUwasilishaji wa data unaoangazia pande mbili kati ya RS485 na Ethernet
Kiolesura cha MawasilianoLango la RS485 x 4, lango la Ethaneti x 1
Ugavi wa NguvuDC 6 - 45V screw terminal, or PoE port
Ulinzi wa KutengwaPower isolation, Signal isolation
EthanetiRJ45 10 / 100M auto-negotiation, 2 KV surge protection, IEEE 802.3af compliant (PoE)
Bandari ya SerialIsolated RS485 (4 channels can receive and transmit independently)
kiwango cha ulevi300 - 115200 bps
Kiwango cha usawaNone, odd, even, mark, space
Bit Bit5 - 9 bits
Udhibiti wa MtiririkoN/A
ItifakiEthernet, IP, TCP, UDP, HTTP, ARP, ICMP, DHCP, DNS
UsanidiMwenyeji, web kivinjari, maktaba ya vipengele vya usimamizi wa kifaa
Mbinu ya MawasilianoMawasiliano ya moja kwa moja ya TCP/IP, VCOM
Hali ya UendeshajiSeva ya TCP, mteja wa TCP (anayeshirikiana na seva ya TCP), UDP, UDP multicast
Joto la Uendeshaji-40°C ~ 85°C
Aina ya unyevuUnyevu wa jamaa wa 5% - 95%
VipimoL × W × H: 91.0 × 64.5 × 24.2 mm
Uzito wa Kipengee7.4 wakia
Detailed specifications table for the waveshare serial server

Picha ya 3: A comprehensive table outlining the technical specifications and version options for the waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server.

5. Kuweka

Follow these steps to set up your waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server:

5.1. Uunganisho wa Nguvu

  • Uingizaji wa Nguvu wa DC: Connect a DC 6-45V power supply to the V+ and V- screw terminals. Ensure correct polarity.
  • PoE (Nguvu juu ya Ethaneti): If using the PoE version, connect a PoE-enabled Ethernet cable to the RJ45 port. This will provide both power and data connectivity.

5.2. Muunganisho wa Mtandao

  • Connect a standard RJ45 Ethernet cable from your network switch or router to the Ethernet port on the module.
  • The module defaults to static IP addresses in the range of 192.168.1.200-192.168.1.204. It is recommended to initially set up the device on an isolated network to avoid IP conflicts.

5.3. RS485 Device Connection

  • Connect your RS485 devices to the corresponding A+, B-, and Signal Ground terminals for each of the four RS485 channels.
  • Ensure correct wiring polarity (A+ to A+, B- to B-) for proper communication.

5.4. Usanidi wa Awali

  • Access the device's configuration interface via a web browser by entering its default IP address (e.g., 192.168.1.200).
  • Alternatively, use the provided VirCom software (available from the Waveshare Wiki) to discover and configure the device on your network.
  • You can change the IP settings to DHCP or assign a static IP within your network range.
Wiring and power options for the waveshare serial server

Picha ya 4: Diagram illustrating the primary function of bi-directional data transmission, multi-power supply options (PoE and screw terminal), and the industrial rail-mount design.

6. Maagizo ya Uendeshaji

The 4-Ch RS485 to RJ45 Ethernet Serial Server supports various operating modes and protocols:

6.1. Multi Communication Modes

  • Seva ya TCP: Supports up to 30 concurrent TCP connections. The module listens on configured ports, and data from serial devices is transferred to connected TCP clients.
  • Mteja wa TCP: Allows concurrent connection to up to 7 target IPs. It can also function as a server simultaneously, supporting 22 concurrent client connections. It establishes bi-directional transparent transfer between the server and serial device.
  • UDP Multicast: In UDP multicast mode, the module sends and receives data to and from a multicast group, reducing network load.
  • Hali ya UDP: The module communicates with specific IP and port numbers, improving data transfer accuracy.

6.2. Modbus Gateway Support

The module functions as a Modbus gateway, facilitating communication between Modbus TCP and Modbus RTU devices. This is ideal for upgrading Modbus networking infrastructure.

6.3. MQTT/JSON to Modbus Conversion

When used as an MQTT gateway, the device can upload serial data to an MQTT server via transparent transmission. It supports various cloud platforms. Acquired Modbus RTU or non-standard serial data can be parsed into JSON format and packaged into MQTT data packets for uploading. As a JSON data acquisition gateway, it can connect to data acquisition instruments via RS485, acquire data, convert it to JSON, and post it to a server. The uploaded data format can be configured via host, and the JSON upload protocol can be MQTT, HTTP POST, HTTP GET, etc.

6.4. Multi Hosts Roll-Polling Support

This feature ensures that different network devices are identified and responded to respectively, preventing crosstalk when communicating with multiple network devices.

6.5. User-Defined Heartbeat/Registration Packet

Facilitates easy cloud communication and device identification through user-defined heartbeat and registration packets.

6.6. NTP Protocol Support

Supports Network Time Protocol (NTP) for obtaining network time information or for data upload synchronization.

6.7. Multi Configuration Methods

The module can be configured using various methods, including a web browser interface, obtaining dynamic IP via DHCP, and DNS protocol connected domain server address. A device management functions library is also available.

Advanced communication features of the waveshare serial server

Picha ya 5: Visual juuview of advanced features such as MQTT/JSON to Modbus conversion, multi-host roll-polling, NTP protocol support, and various configuration methods.

7. Introduction Introduction

Understanding the physical interfaces and indicators is crucial for proper operation:

7.1. Physical Interfaces

  • Kitufe cha RST: Used to reset the device to factory default settings.
  • Ingizo la Nguvu la DC 6-45V: Screw terminals for connecting external DC power (V+, V-).
  • RS485 Ports (1-4): Each port has A+, B-, and Signal Ground terminals for connecting RS485 devices.
  • PoE ETH Port: RJ45 connector for Ethernet and Power over Ethernet (PoE) input.

7.2. Maelezo ya Kiashirio

  • PWR (Kiashiria cha Nguvu): Huangaza wakati kifaa kimewashwa.
  • NET (Network Indicator): Blinks when connected to the Ethernet network.
  • LINKx (Link Indicator): Lights up when a connection is established on the corresponding RS485 channel (x=1, 2, 3, 4).
  • ACTx (Activity Indicator): Lights up when data is being transmitted on the corresponding RS485 channel (x=1, 2, 3, 4).
Interface layout and LED indicators of the waveshare serial server

Picha ya 6: Kina view of the device's interfaces, including the reset button, power input, RS485 terminals, Ethernet port, and a description of the LED indicators (PWR, NET, LINKx, ACTx).

8. Multiple Protection, Safe And Stable

The module is designed with multiple protection mechanisms to ensure high reliability and strong anti-interference capabilities:

  • Digital Isolation: Provides isolation for digital signals.
  • Ulinzi wa ESD: Electrostatic Discharge protection.
  • Ulinzi wa Sasa hivi: Ulinzi dhidi ya mkondo mwingi.
  • Zaidi ya voltage Ulinzi: Hulinda dhidi ya ujazotage spikes.
  • TVS Protection: Built-in Transient Voltage Suppression (TVS) tube effectively suppresses surge voltage na kilele cha mpito voltage katika mzunguko.
  • Resettable Fuse & Protection Diode: Ensures stable output of current and voltage, preventing over-current and over-voltage, and improving shock-proof performance.

9. Aluminium Alloy Enclosure

The device features a durable aluminum alloy enclosure with sandblasting and anodic oxidation treatment. This robust construction provides solid protection, a good hand feeling, and supports both wall-mount and rail-mount installations for industrial environments.

10. Vipimo vya Muhtasari

The physical dimensions of the module are as follows:

  • Urefu (L): 91.0 mm
  • Upana (W): 64.5 mm
  • Urefu (H): 24.2 mm
Outline dimensions and customization options for the waveshare serial server

Picha ya 7: Diagram showing the precise outline dimensions of the module in millimeters, along with information on batch customization support.

11. Matengenezo

To ensure the longevity and optimal performance of your waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server, consider the following maintenance guidelines:

  • Ukaguzi wa Mara kwa Mara: Periodically check all cable connections (power, Ethernet, RS485) to ensure they are secure and free from damage.
  • Udhibiti wa Mazingira: Operate the device within the specified operating temperature (-40°C ~ 85°C) and humidity (5% - 95% relative humidity) ranges. Avoid exposure to extreme conditions, dust, and moisture.
  • Kusafisha: Keep the device clean and free from dust accumulation. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
  • Sasisho za Firmware: Check the official Waveshare website or Wiki periodically for any available firmware updates. Applying updates can improve performance, add features, or fix bugs.
  • Kuendesha Baiskeli kwa Nguvu: If the device becomes unresponsive, perform a power cycle (disconnect and reconnect power) as a first troubleshooting step.

12. Utatuzi wa shida

This section addresses common issues you might encounter with the waveshare 4-Ch RS485 to RJ45 Ethernet Serial Server:

12.1. No Power / Power LED Off

  • Angalia Ugavi wa Nguvu: Ensure the DC 6-45V power supply is correctly connected to the screw terminals and is providing the correct voltage.
  • Angalia PoE: Ikiwa unatumia PoE, hakikisha kwamba kebo ya Ethernet imeunganishwa kwenye lango linalowezeshwa na PoE kwenye swichi/kiingizaji chako na kwamba chanzo cha PoE kinafanya kazi.
  • Kagua Wiring: Confirm that the power wires are securely fastened in the screw terminals and that there are no shorts or breaks.

12.2. No Network Connectivity / NET LED Not Blinking

  • Cable ya Ethernet: Ensure the RJ45 Ethernet cable is securely connected to both the module and your network device. Try a different cable.
  • Usanidi wa Mtandao: The device defaults to static IPs (192.168.1.200-192.168.1.204). Ensure your PC is on the same subnet (e.g., 192.168.1.x) to access the web interface or use the VirCom software.
  • IP Conflicts: If other devices on your network use the default IPs, configure the module on an isolated network first, then change its IP settings.
  • DHCP Settings: If configured for DHCP, ensure a DHCP server is available on your network.

12.3. RS485 Communication Failure / ACTx LED Not Blinking

  • Wiring: Double-check the RS485 wiring (A+ to A+, B- to B-) between the module and your serial devices. Ensure Signal Ground is also connected if required.
  • Vigezo vya Mfululizo: Verify that the baud rate, parity bit, and data bit settings on the module match those of your connected RS485 devices.
  • Anwani ya Kifaa: For Modbus or other protocols, ensure correct device addressing and commands are being used.
  • Kujitenga: While the module provides isolation, ensure external RS485 devices are also properly isolated or grounded to prevent ground loops.

12.4. Cannot Access Configuration Interface

  • IP chaguo-msingi: Confirm you are using the correct default IP address (e.g., 192.168.1.200) or the IP you previously assigned.
  • Muunganisho wa Mtandao: Ensure your PC is on the same subnet as the module.
  • VirCom Software: Use the Waveshare VirCom software to discover the device's IP address if it's unknown.
  • Firewall: Temporarily disable your computer's firewall to rule out blocking access.
  • Rudisha: If all else fails, press the RST button to restore factory default settings (this will reset the IP to default).

For more detailed troubleshooting and advanced configurations, please refer to the official Waveshare Wiki for the 4-CH RS485 TO POE ETH (B) module.

13. Udhamini na Msaada

This waveshare product is designed for reliability and performance. For specific warranty terms and conditions, please refer to the purchase documentation or contact your vendor. Waveshare provides technical support and resources to assist with product usage and troubleshooting.

13.1. Msaada wa Kiufundi

For technical assistance, detailed documentation, and software downloads, please visit the official Waveshare website or their product Wiki. The Wiki often contains comprehensive guides, examples, and FAQs that can help resolve complex issues.

13.2. Maelezo ya Mawasiliano

You can typically find contact information for Waveshare support on their official website. Please have your product model (4-CH RS485 TO POE ETH (B)) and any relevant purchase details ready when seeking support.

Nyaraka Zinazohusiana - 4-CH RS485 TO POE ETH (B)

Kablaview Waveshare RS485 TO ETH (B) User Manual - Industrial RS485 to Ethernet IoT Gateway
Comprehensive user manual for the Waveshare RS485 TO ETH (B), an industrial serial device server and IoT gateway. Learn about its features, applications, configuration, and how to connect RS485 devices to Ethernet for Modbus, MQTT, and cloud integration.
Kablaview Mwongozo wa Mtumiaji wa Waveshare UART TO ETH (B): Mwongozo wa Kibadilishaji cha Mfululizo hadi Ethernet
Mwongozo kamili wa mtumiaji wa moduli ya Waveshare UART TO ETH (B), inayoelezea vipengele vyake kama kibadilishaji cha UART hadi Ethernet, lango la IoT, lango la Modbus, na seva ya mfululizo kwa matumizi ya viwandani.
Kablaview Vipimo vya Kiufundi vya Lango la Ethernet la RS232/RS485 hadi Ethernet & PoE
Hati hii inatoa vipimo vya kina, vipengele vya vifaa na programu, na taratibu za majaribio ya Waveshare RS232/RS485 kwa milango ya Ethernet na PoE Ethernet. Vifaa hivi hufanya kazi kama seva za mfululizo, milango ya Modbus, na milango ya MQTT kwa ajili ya upatikanaji wa data ya viwandani na muunganisho wa IoT.
Kablaview Mwongozo wa Mtumiaji wa Waveshare RS232/485 hadi Ethernet Converter
Hii ni moduli ya RS232/485 hadi Ethernet ya kiwango cha viwandani kutoka Waveshare, inayowezesha uwasilishaji wa data unaoangazia pande mbili kati ya milango ya Ethernet ya RS232, RS485, na RJ45. Ina kichakataji cha ARM M4 cha biti 32, Ethernet ya 10/100M, hali nyingi za uendeshaji (Seva/Mteja wa TCP, UDP, HTTPD), lango la Modbus, na Webusaidizi wa soketi, unaotoa kasi ya juu, matumizi ya chini ya nguvu, na uthabiti kwa matumizi ya IoT ya viwandani.
Kablaview Mwongozo wa Mtumiaji wa Mawasiliano wa Waveshare RS485 hadi WiFi/ETH MQTT
Mwongozo kamili wa mtumiaji wa moduli ya Waveshare RS485 hadi WiFi/ETH, inayowaongoza watumiaji kupitia utayarishaji wa programu na vifaa, usanidi wa mtandao, na kuanzisha mawasiliano ya MQTT na mifumo kama EMQX.
Kablaview Mwongozo wa Mtumiaji wa Waveshare RS232/485 kwa WiFi PoE Ethernet (B) Seva ya Mfululizo
Chunguza Mwongozo wa Mtumiaji wa Waveshare RS232/485 kuwa WiFi PoE Ethernet (B), mwongozo kamili wa seva ya mfululizo inayobadilisha RS232/485 kuwa violesura vya mtandao vya TCP/IP, na kuwezesha uwasilishaji wa data pande mbili kupitia WiFi na Ethernet.