1. Utangulizi
This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN 4500LM/30W Motion Sensor Outdoor Flood Light. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

Image 1: OREiN 4500LM/30W Motion Sensor Outdoor Flood Light, front view with three adjustable light heads and a motion sensor below.
2. Taarifa za Usalama
ONYO: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Hakikisha usambazaji wa umeme umezimwa kabla ya kuanza usakinishaji.
- Use only approved connectors and wiring suitable for outdoor use.
- Usijaribu kurekebisha kifaa. Marekebisho yoyote yanaweza kubatilisha udhamini na kusababisha hatari za usalama.
- Wasiliana na fundi umeme aliyehitimu ikiwa huna uhakika kuhusu sehemu yoyote ya mchakato wa usakinishaji.
- This fixture is designed for outdoor use and is IP65 waterproof rated.
3. Yaliyomo kwenye Kifurushi
Thibitisha kuwa vipengele vyote vipo kabla ya kuanza usakinishaji:
- Mpangilio wa Mwanga (1)
- Kupakia Bracket (1)
- Screws (for mounting)
- Wire Nuts (for electrical connections)
- Mwongozo wa maagizo (1)
4. Bidhaa za Bidhaa
- High Brightness & Efficiency: 4500 Lumens output with 30W power consumption, offering 150LM/W efficiency.
- Adjustable Motion Sensor: 180° wide sensing angle with a detection range up to 50 feet.
- Njia tatu za Uendeshaji: TEST Mode, AUTO Mode, and Dusk-to-Dawn (D2D) Mode for versatile lighting control.
- Inadumu & Inayostahimili hali ya hewa: IP65 waterproof rating, constructed from polycarbonate material for resistance against rain, dust, snow, and extreme temperatures.
- Ufungaji Unaobadilika: Supports both wall mounting and soffit mounting.
- Vichwa vya Mwanga vinavyoweza Kubadilishwa: Three light heads can be independently adjusted to direct illumination where needed.
- Joto la Rangi: 5000 Kelvin (white light).

Image 2: Illustration demonstrating the IP65 waterproof rating, showing the flood light enduring rain, snow, and wind.

Image 3: Diagram showing the flexible adjustment angles of the three light heads (up to 340° horizontally, 90° vertically) and the motion sensor (up to 270° horizontally, 120° vertically).
5. Kuweka na Kuweka
This flood light is hardwired and requires connection to your home's electrical system. Professional installation is recommended.
- Zima Nguvu: Kabla ya kuanza, hakikisha umeme kwenye eneo la usakinishaji umezimwa kwenye kivunja mzunguko.
- Mabano Salama ya Kupachika: Ambatisha bracket ya kupachika kwenye kisanduku cha makutano kwa kutumia skrubu zilizotolewa. Hakikisha imefungwa vizuri.
- Unganisha Waya: Connect the household wiring to the light fixture's wires using the provided wire nuts. Typically, black to black (live), white to white (neutral), and green/bare copper to green (ground).
- Linda Mpangilio wa Mwanga: Mount the light fixture onto the mounting bracket, ensuring a tight and secure fit.
- Insert Waterproof Plug: Ensure any necessary waterproof plugs are properly inserted to maintain the IP65 rating.
- Rekebisha Vichwa vya Mwanga: Position the three light heads to cover the desired illumination area.

Image 4: Step-by-step diagram illustrating the hardwired installation process, including securing the mounting bracket, connecting wires, and attaching the light fixture.

Picha 5: Kutamples of the flood light installed in both wall-mounted and soffit-mounted configurations.
6. Maagizo ya Uendeshaji
The OREiN flood light features an adjustable motion sensor with three distinct operating modes:

Picha 6: Karibu view of the motion sensor controls, showing dials for TIME (1/5/10 minutes), SENSITIVITY (10ft/20ft/30ft/Max 50ft), and a switch for MODE (TEST/AUTO/D2D).
Uteuzi wa Hali:
- Hali ya Mtihani: The light turns on for a fixed 5-second duration when motion is detected, regardless of ambient light. This mode is used for testing the sensor's coverage area during installation.
- Hali ya Otomatiki: The light activates only at night when motion is detected. The duration the light stays on and the sensitivity of the sensor can be adjusted.
- D2D (Dusk-to-Dawn) Mode: The light automatically turns on at dusk and turns off at dawn, providing continuous illumination throughout the night. Motion sensing is not active in this mode.

Image 7: Visual explanation of the three operating modes: Test Mode (light on for 5s with motion), D2D Mode (light on all night), and Auto Mode (light on at night with motion for adjustable time).
Adjusting Settings (AUTO Mode):
- TIME Dial: Adjusts how long the light stays on after motion is detected. Options typically include 1, 5, or 10 minutes.
- SENSITIVITY Dial: Adjusts the detection range of the motion sensor. Options typically include 10ft, 20ft, 30ft, or Max (up to 50ft). A higher sensitivity setting means a longer detection distance.
7. Matengenezo
Regular maintenance ensures optimal performance and longevity of your flood light.
- Kusafisha: Safisha taa mara kwa mara na lenzi ya kitambuzi cha mwendo kwa laini, damp kitambaa. Usitumie visafishaji vya abrasive au vimumunyisho.
- Ukaguzi: Kagua mara kwa mara wiring na kupachika kwa dalili zozote za uchakavu, uharibifu au kulegea. Shughulikia maswala yoyote mara moja.
- Hakuna Ubadilishaji wa Balbu: This LED fixture does not require bulb replacement. The integrated LEDs are designed for long-term use.
8. Utatuzi wa shida
If you encounter issues with your OREiN flood light, refer to the following common problems and solutions:
- Mwanga hauwashi:
- Ensure power is supplied to the fixture and the circuit breaker is not tripped.
- Check the mode setting. In AUTO mode, it will only activate at night. In D2D mode, it will only activate at dusk.
- Verify the motion sensor is not obstructed.
- Mwanga hubaki ukiwaka kila wakati:
- If in D2D mode, this is normal operation.
- If in AUTO mode, reduce the SENSITIVITY setting. Environmental factors like moving branches or passing vehicles can trigger the sensor.
- Ensure the TIME dial is set correctly.
- Kihisi mwendo hakigundui:
- Increase the SENSITIVITY setting.
- Ensure the sensor lens is clean and unobstructed.
- Verify the sensor is aimed correctly towards the desired detection area.
9. Vipimo
| Kipengele | Vipimo |
|---|---|
| Chapa | OREiN |
| Jina la Mfano | OL3600354 |
| Vipimo vya Bidhaa | 7.6"L x 8"W x 6"H |
| Uzito wa Kipengee | Pauni 1.92 |
| Mwangaza | 4500 Lumens |
| Wattage | 30 watts |
| Joto la Rangi | 5000 Kelvin (Mwanga Mweupe) |
| Kiwango cha Upinzani wa Maji | IP65 Inayozuia maji |
| Pembe ya Kutambua Mwendo | 180° |
| Umbali wa Kuhisi Mwendo | Hadi futi 50 |
| Chanzo cha Nguvu | AC/DC (Hardwired) |
| Nyenzo | Acrylonitrile Butadiene Styrene (ABS) |
| Aina ya Ufungaji | Mlima wa Ukuta na Mlima wa Dari |
| Voltage | 120 Volts |
| Vipengee vilivyojumuishwa | Light Fixture, Mounting Bracket, Screws, Wire Nuts, Instruction Manual |

Image 8: Comparison table showing specifications for different OREiN 3-head flood light models, including the 4500LM/30W version.
10. Udhamini
This OREiN flood light is covered by a dhamana ya miezi 24 kuanzia tarehe ya ununuzi. Tafadhali hifadhi uthibitisho wako wa ununuzi kwa madai ya udhamini. Udhamini hufunika kasoro katika vifaa na utengenezaji chini ya matumizi ya kawaida.
11. Msaada
For any questions, technical assistance, or warranty inquiries, please contact OREiN customer support:
- Usaidizi wa Simu: 1-844-506-1530 (available during working hours)
- Msaada wa Mtandaoni: 7 days a week, 24 hours a day. Please refer to the official OREiN website or contact through the Amazon platform for online support options.