1. Utangulizi
This manual provides essential instructions for the safe operation, maintenance, and troubleshooting of your Champion Power Equipment 6875/5500-Watt Dual Fuel Portable Generator, Model 201085. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.
This generator is designed to provide reliable power using either gasoline or propane, featuring a 389cc Champion engine and CO Shield technology for enhanced safety.

Image 1.1: The Champion Power Equipment 6875/5500-Watt Dual Fuel Portable Generator.
2. Taarifa za Usalama
WARNING: Generators produce carbon monoxide, a colorless, odorless, poisonous gas. Using a generator indoors CAN KILL YOU IN MINUTES.
- Matumizi ya Nje Pekee: Always operate the generator outdoors in a well-ventilated area, far away from windows, doors, and vents of occupied buildings. Direct exhaust away from people and buildings.
- CO Shield Technology: This generator is equipped with CO Shield technology, which monitors carbon monoxide (CO) accumulation. If unsafe elevated levels of CO gas are detected, the engine will automatically shut off. CO Shield is not a substitute for an indoor carbon monoxide alarm or for safe operation.
- Usalama wa Mafuta: Gasoline is highly flammable. Store fuel in approved containers in a well-ventilated area. Do not refuel a hot or running engine. Propane tanks must be secured and stored outdoors.
- Usalama wa Umeme: Do not operate the generator in wet conditions. Ensure all electrical connections are secure and properly grounded. Use GFCI-protected outlets when available.
- Read All Warnings: Familiarize yourself with all safety decals on the generator and in this manual.

Image 2.1: The CO Shield feature provides automatic carbon monoxide auto-shutoff for safety.
3. Yaliyomo kwenye Kifurushi
Champion Power Equipment generator package includes the following items:
- Champion 6875/5500-Watt Dual Fuel Portable Generator
- Engine Oil (1.2 quarts of 10W-30)
- Propane (LPG) Hose with Regulator (6.5 feet)
- Wheel Kit (for assembly)
- Funnel ya Mafuta
- Spark Plug Wrench (not explicitly listed but typically included)

Image 3.1: Included accessories for your generator.
4. Kuweka
4.1 Mkutano
- Ambatanisha Magurudumu: Securely attach the wheels to the generator frame using the provided hardware.
- Ambatisha Miguu ya Kusaidia: Install the support legs to ensure stability.
- Ambatisha Kitovu: Assemble the handle for easy portability.
4.2 Add Engine Oil
Jenereta husafirishwa bila mafuta ya injini. Ni muhimu kuongeza kiasi na aina sahihi ya mafuta kabla ya matumizi ya kwanza.
- Weka jenereta kwenye uso ulio sawa.
- Ondoa kofia ya kujaza mafuta / dipstick.
- Using the included funnel, slowly pour the entire 1.2 quarts of 10W-30 engine oil into the crankcase.
- Sakinisha tena kofia/kijiti cha kujaza mafuta na kaza kwa usalama.
4.3 Fueling Options
This generator operates on either gasoline or propane.
- Petroli: Use unleaded gasoline with an octane rating of 87 or higher. Do not use E85 or mixed fuels. Fill the 7.7-gallon fuel tank carefully, avoiding overfilling.
- Propani (LPG): Connect the provided propane hose to a standard 20-pound (or larger) propane tank and to the generator's propane inlet. Ensure all connections are tight.

Image 4.1: Key features including dual fuel selection and power outlets.
5. Maagizo ya Uendeshaji
5.1 Jopo la Kudhibiti Imeishaview

Image 5.1: The generator's control panel, showing the fuel select dial, Intelligauge display, CO Shield indicator, circuit breakers, and various outlets.
- Fuel Select Dial: Allows switching between gasoline and propane.
- Akili: Maonyesho juzuu yatage, frequency, and run-time hours.
- CO Shield Indicator: LED light indicates CO shutoff or fault.
- Maduka: Includes one 120/240V 30A locking outlet (L14-30R) and four 120V 20A GFCI protected household outlets (5-20R). All outlets have covers for protection.
- Vivunja Mzunguko: Protect against overloads.
5.2 Kuanzisha Jenereta
- Hakikisha jenereta iko kwenye usawa na mizigo yote ya umeme imekatwa.
- Chagua Mafuta: Turn the fuel select dial to either 'Gasoline' or 'Propane'.
- Choka: Move the choke lever to the 'Choke' position (if the engine is cold).
- Anza: Pull the recoil start handle firmly and steadily until the engine starts.
- Choke (Warm-up): Once the engine starts, slowly move the choke lever to the 'Run' position.
- Allow the engine to run for a few minutes to warm up before connecting electrical loads.
5.3 Kuunganisha Mizigo ya Umeme
Once the generator is running smoothly, you can connect your appliances or tools to the appropriate outlets. Do not exceed the generator's running wattage capacity (5500W on gasoline, 5000W on propane).

Image 5.2: The generator provides power for various applications, such as remote work sites.
6. Matengenezo
Regular maintenance ensures the longevity and reliable performance of your generator.
6.1 Ratiba ya Matengenezo
- Kabla ya Kila Matumizi: Check engine oil level, inspect air filter, check fuel level, inspect for loose hardware.
- Saa 5 za Kwanza: Badilisha mafuta ya injini.
- Every 50 Hours or Annually: Change engine oil, clean air filter, inspect spark plug, inspect fuel filter.
- Every 100 Hours or Annually: Clean spark arrestor, inspect valve clearance (recommended by qualified technician).
6.2 Mabadiliko ya Mafuta ya Injini
- Endesha injini kwa dakika chache ili joto mafuta, kisha uifunge.
- Weka sufuria ya kukimbia chini ya kuziba ya kukimbia mafuta.
- Remove the oil drain plug and oil fill cap/dipstick to allow oil to drain completely.
- Sakinisha tena plagi ya kukimbia mafuta.
- Add 1.2 quarts of fresh 10W-30 engine oil.
- Reinstall the oil fill cap/dipstick.
6.3 Kusafisha Kichujio cha Hewa
A dirty air filter can reduce engine performance and lifespan.
- Ondoa kifuniko cha chujio cha hewa.
- Ondoa kipengele cha chujio cha povu.
- Wash the foam element in warm, soapy water, then rinse thoroughly.
- Squeeze out excess water and allow to air dry completely.
- Lightly apply engine oil to the foam, then squeeze out excess oil.
- Reinstall the foam element and air filter cover.
6.4 Hifadhi
For extended storage, prepare the generator as follows:
- Drain the gasoline from the fuel tank and carburetor, or add a fuel stabilizer.
- Tenganisha tanki la propane.
- Badilisha mafuta ya injini.
- Ondoa plagi ya cheche na mimina kiasi kidogo cha mafuta ya injini kwenye silinda. Vuta kamba ya kurudisha nyuma mara chache ili kusambaza mafuta, kisha usakinishe tena plagi ya cheche.
- Safisha nje ya jenereta.
- Hifadhi katika sehemu safi, kavu na yenye uingizaji hewa wa kutosha.
7. Utatuzi wa shida
This section addresses common issues you might encounter with your generator.
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| Injini haitaanza | No fuel (gasoline or propane) Mafuta ya injini ya chini Choke haijawekwa kwa usahihi Tatizo la kuziba cheche | Ongeza mafuta Ongeza mafuta ya injini Kurekebisha lever ya choke Kagua/safisha/badilisha plagi ya cheche |
| Hakuna pato la umeme | Kivunja mzunguko kimejikwaa Kupakia kupita kiasi Muunganisho mbovu | Weka upya kivunja mzunguko Reduce electrical load Angalia miunganisho yote |
| Injini inasimama bila kutarajia | Mafuta ya injini ya chini CO Shield activated Ukosefu wa mafuta | Angalia / ongeza mafuta ya injini Move generator to a better ventilated area, allow to cool, then restart Weka mafuta |
| Injini inaenda vibaya | Kichujio cha hewa chafu Mafuta ya zamani Tatizo la kuziba cheche | Safi/badilisha chujio cha hewa Futa na ubadilishe mafuta Kagua/safisha/badilisha plagi ya cheche |
8. Vipimo
Detailed technical specifications for the Champion Power Equipment Model 201085 generator:
- Mfano: 201085
- Starting Watts (Gasoline): 6875 Watts
- Running Watts (Gasoline): 5500 Watts
- Starting Watts (Propane): 6250 Watts
- Running Watts (Propane): 5000 Watts
- Aina ya Mafuta: Gasoline, Propane (Dual Fuel)
- Uhamisho wa Injini: 389cc (4-Stroke)
- Uwezo wa Tangi ya Mafuta: Galoni 7.7
- Uwezo wa Mafuta: 1.2 Quarts (10W-30)
- Maduka: 1x 120/240V 30A Locking (L14-30R), 4x 120V 20A GFCI (5-20R)
- Vipengele Maalum: CO Shield, Volt Guard, Intelligauge
- Uzito wa Kipengee: Pauni 165
- Vipimo vya Bidhaa: 28.3"L x 27.4"W x 25.6"H
- UPC: 817198024950

Image 8.1: Physical dimensions and weight of the generator.
9. Udhamini na Msaada
Champion Power Equipment stands behind its products with comprehensive support.
9.1 Taarifa ya Udhamini
This generator comes with a Udhamini mdogo wa mwaka 3. This warranty covers defects in material and workmanship under normal use and maintenance. Please refer to the warranty card included with your product for full terms and conditions.

Image 9.1: The generator is backed by a 3-year limited warranty.
9.2 Msaada wa Kiufundi
Champion Power Equipment offers FREE lifetime technical support from dedicated experts. For assistance, please contact Champion Support through their official website or customer service line. Have your model number (201085) and serial number ready when contacting support.
For additional resources and product registration, visit the Champion Duka la Vifaa vya Nguvu.