1. Utangulizi
The Xetron STC-1000Pro is a versatile digital temperature controller designed for precise temperature management in various environments. It features dual outlets for simultaneous heating and cooling control, a wide temperature range, and user-friendly operation. This manual provides detailed instructions for setting up, operating, and maintaining your device.

Figure 1: Xetron STC-1000Pro Digital Temperature Controller. This image displays the main unit with its digital display, control buttons, power cord, temperature sensor, and the dual-outlet power strip for heating and cooling devices.
Maombi
The STC-1000Pro is suitable for a wide range of applications requiring accurate temperature control, including:
- Reptile enclosures and terrariums
- Home brewing and fermentation
- Incubators
- Nyumba za kijani kibichi
- Aquariums
- Friji

Figure 2: Common applications for the Xetron STC-1000Pro. This image illustrates the controller's use in home brewing, incubators, aquariums, and flower cultivation, highlighting its versatility.
2. Sifa Muhimu
- Ideal Temperature Control: Two outlets allow simultaneous or separate connection of heating and cooling equipment for automatic temperature switching. Wide control range of -40 to 230 β (-40 to 110 β) with a temperature accuracy of Β±1 β / Β±2 β.
- Muundo Unaofaa Mtumiaji: Simple 3-button operation and pre-wired design for plug-and-play functionality. Large display for easy real-time data reading.
- Mfumo wa Alarm mbili: Adjustable high/low temperature alarms with audible beeps and a bell icon on the display, ensuring timely alerts even when not near the device.
- Vigezo Vinavyoweza Kubinafsishwa: Supports settings for β/β unit switching, temperature calibration, high and low alarm values, start delay, and protection time (cooling mode only).
- Usalama na Ubora: Constructed from V-0 flame-retardant ABS material. Features compressor delay protection and complies with CE and FCC standards for safe operation.
- Kichunguzi cha Kuzuia Maji cha IP65: The temperature probe head can be immersed in fresh water, and the main unit features an internal rubber ring to prevent water ingress.

Figure 3: Temperature control range of the Xetron STC-1000Pro. This image highlights the controller's ability to maintain temperatures within a desired range of -40 to 230 β using both cooling and heating devices.

Figure 4: Large screen display of the Xetron STC-1000Pro. The image shows the display dimensions and labels for PV (Present Value), SV (Set Value), Csp (Cooling Start Point), and Hsp (Heating Start Point), indicating β/β switchability.

Figure 5: Visual and audible alert features. This image illustrates the double alarm and delay protection functionalities of the controller, enhancing safety and monitoring.

Figure 6: Safety and quality certifications. The image highlights the V-0 flame-retardant ABS material and compliance with CE, FCC, and RoHS standards, ensuring product safety.

Figure 7: IP65 waterproof features. This image demonstrates the waterproof capability of the temperature probe, which can be immersed in fresh water, and the internal rubber ring for main unit protection.
3. Maagizo ya Kuweka
- Fungua Kifaa: Carefully remove the Xetron STC-1000Pro controller and its components from the packaging.
- Unganisha Kihisi: Ensure the temperature sensor is fully inserted into its dedicated port on the side of the controller. A loose connection can lead to "ERR" display.
- Weka Sensorer: Place the temperature probe in the environment where temperature monitoring and control are required. Ensure it is not directly exposed to heating or cooling elements to get an accurate reading.
- Connect Heating/Cooling Devices:
- Plug your heating device (e.g., heat lamp, heating mat) into the socket labeled "HEATING".
- Plug your cooling device (e.g., fan, chiller) into the socket labeled "COOLING".
Muhimu: The maximum output for each socket is 10A at 240VAC. Do not connect high-power equipment exceeding these limits.
- Washa: Plug the controller's main power cord into a standard 230V AC power outlet. The display will illuminate, showing the current temperature (PV) and other settings.

Figure 8: Plug-and-play setup of the Xetron STC-1000Pro. This image demonstrates the simplicity of connecting the controller, showing it mounted on a wall next to a terrarium, with heating/cooling devices plugged in.
4. Maagizo ya Uendeshaji
The STC-1000Pro features a simple 3-button interface: WEKA, JUU (β²), na CHINI (βΌ).
4.1 Onyesha Juuview
- PV (Present Value): Displays the current measured temperature.
- SV (Thamani ya Weka): Displays the target temperature you wish to maintain.
- Csp (Cooling Start Point): The temperature at which the cooling device will activate.
- Hsp (Heating Start Point): The temperature at which the heating device will activate.
4.2 Setting the Target Temperature (SV)
- Bonyeza kwa WEKA button once. The SV value will flash.
- Tumia JUU (β²) or CHINI (βΌ) vifungo vya kurekebisha halijoto inayolengwa.
- Bonyeza WEKA again to confirm and save the setting, or wait a few seconds for it to save automatically.
4.3 Mipangilio ya Kigezo cha Juu
To access advanced settings, press and hold the WEKA button for approximately 3 seconds until the display changes to show parameter codes.

Figure 9: Diagram illustrating parameter settings. This image shows the relationship between TS (Temperature Set-point), CD (Cooling Differential), HD (Heating Differential), Csp (Cooling Start Point), and Hsp (Heating Start Point).
Tumia JUU (β²) or CHINI (βΌ) buttons to navigate through the parameters. Press WEKA to enter a parameter's value, then use JUU (β²) or CHINI (βΌ) to adjust, and WEKA tena kuokoa.
| Kigezo | Maelezo | Masafa | Chaguomsingi |
|---|---|---|---|
| TS (Temperature Set-point) | The desired target temperature (same as SV). | -40 to 110 β / -40 to 230 β | Inatofautiana |
| CD (Cooling Differential) | The difference between the cooling start point (Csp) and the set temperature (TS). Cooling activates when PV β₯ TS + CD. | 0.1 to 30 β / 0.1 to 54 β | 2 β / 3.6 β |
| HD (Heating Differential) | The difference between the heating start point (Hsp) and the set temperature (TS). Heating activates when PV β€ TS - HD. | 0.1 to 30 β / 0.1 to 54 β | 2 β / 3.6 β |
| PT (Protection Time) | Compressor delay protection time (in minutes) for cooling mode only. Prevents frequent compressor cycling. | Dakika 0 hadi 10 | dakika 3 |
| CA (Temperature Calibration) | Adjusts the temperature reading to match an external reference thermometer. | -10 to 10 β / -18 to 18 β | 0 β / 0 β |
| CF (Unit Switch) | Switches between Celsius (β) and Fahrenheit (β). | C / F | C |
| HA (High Alarm) | Sets the upper temperature limit for the alarm. | TS to 110 β / TS to 230 β | 110 β / 230 β |
| LA (Low Alarm) | Sets the lower temperature limit for the alarm. | -40 β / -40 β to TS | -40 β / -40 β |
After adjusting parameters, press and hold WEKA again for 3 seconds to exit the advanced settings menu and return to normal operation.
5. Matengenezo
- Kusafisha: Disconnect the power before cleaning. Wipe the controller's surface with a soft, damp cloth. Do not use abrasive cleaners or immerse the main unit in water. The temperature probe can be cleaned with water.
- Hifadhi: Store the device in a dry environment within the temperature range of -20 β to 75 β (-4 β to 167 β) to ensure the longest possible lifespan.
- Utunzaji wa Sensor: Ensure the temperature sensor cable is not pinched or damaged. A damaged sensor can lead to inaccurate readings or error messages.
6. Utatuzi wa shida
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| "ERR" displayed on screen | Temperature sensor not fully inserted or damaged; temperature exceeds measurement range. | Ensure the sensor is fully inserted into its port. If the issue persists, the sensor may be faulty and require replacement. If the temperature is outside the -40 to 110 β range, the controller will display "ERR". |
| Alarm sounds and bell icon appears | Current temperature (PV) has exceeded the set high alarm (HA) or fallen below the low alarm (LA) threshold. | Check the environmental conditions. Adjust HA/LA settings if necessary. The controller will disable all outputs in fault alarm mode to protect equipment. |
| Heating/Cooling device not activating | Incorrect temperature settings (TS, CD, HD); compressor delay protection (PT) active; device not properly plugged in; device malfunction. | Verify TS, CD, and HD settings. Wait for the PT delay to expire in cooling mode. Ensure devices are securely plugged into the correct outlets. Test heating/cooling devices independently. |
| Usomaji wa joto usio sahihi | Sensor placement; temperature calibration (CA) offset. | Relocate the sensor to a more representative area. Use the CA parameter to calibrate the reading against a known accurate thermometer. |
7. Vipimo
| Kipengele | Maelezo |
|---|---|
| Nambari ya Mfano | XT-STC1000Pro-01US |
| Chapa | Xetron |
| Voltage | 230V AC (Note: Product description mentions 230V, specifications mention 110V. User should verify their specific model's voltage mahitaji.) |
| Pato la Sasa | 10A kwa kila soketi |
| Kiwango cha Udhibiti wa Joto | -40 β hadi 110 β (-40 β hadi 230 β) |
| Usahihi wa Joto | Β±1 β / Β±2 β |
| Aina ya Kuonyesha | OLED |
| Nyenzo | Flame-retardant ABS Plastic |
| Vipimo vya Bidhaa (L x W x H) | 20 x 15 x 6 cm |
| Uzito | gramu 400 |
| Joto la Uendeshaji | Hadi 110 β |
| Vipengee vilivyojumuishwa | 1x Temperature Controller |
8. Maonyo na Tahadhari za Usalama
- Mzigo wa Umeme: Do not connect equipment with a total power consumption exceeding 10A (2400W at 240V) to each outlet. Overloading can cause damage to the controller and connected devices, and poses a fire hazard.
- Voltage Utangamano: Ensure the controller's voltage (230V) inalingana na usambazaji wa umeme wa eneo lako.
- Mfiduo wa Maji: While the probe is waterproof, the main controller unit is not designed for immersion. Avoid exposing the main unit to direct water spray or submersion.
- Uadilifu wa Kihisi: Always ensure the temperature sensor is fully and securely inserted. A short-circuited or damaged sensor will trigger a fault alarm and disable outputs for protection.
- Watoto na Wanyama wa Kipenzi: Keep the device and its cables out of reach of children and pets to prevent accidental damage or injury.
- Uingizaji hewa: Hakikisha kuna uingizaji hewa wa kutosha kuzunguka kidhibiti ili kuzuia joto kupita kiasi.
9. Msaada na Maelezo ya Mawasiliano
For any questions, technical assistance, or customer service inquiries regarding your Xetron STC-1000Pro Digital Temperature Controller, please contact Xetron customer support. We are committed to providing satisfactory customer service.
Tafadhali rejelea kifungashio cha bidhaa au cha muuzaji webtovuti kwa maelezo ya sasa ya mawasiliano.