ESAB G250

Mwongozo wa Maelekezo ya Vidhibiti vya Oksijeni na Asetilini vya ESAB Victor G250 Series

Model: G250 Series | Brand: ESAB

1. Utangulizi na Zaidiview

This manual provides essential information for the safe and effective use of your ESAB Victor G250 Series Oxygen and Acetylene Regulators. These single-stage regulators are designed for applications where slight delivery pressure increases will not significantly affect work performance or test results. The G250 series is engineered for everyday gas regulation needs with no reduction in quality, making them suitable for medium-duty industrial applications.

Set of Victor G250 Oxygen and Acetylene Regulators
Image 1.1: A set of Victor G250 Oxygen (green knob) and Acetylene (red knob) regulators, showing their compact design and clear gauges.

2. Taarifa za Usalama

ONYO: Failure to follow these safety instructions can result in serious injury or death. Always refer to local safety regulations and standards for gas handling and welding operations.

3. Yaliyomo kwenye Kifurushi

Your ESAB Victor G250 Series Regulators package typically includes:

Inspect all components for any signs of damage during shipping. If any items are missing or damaged, contact your supplier immediately.

4. Maagizo ya Kuweka

Follow these steps carefully to set up your Victor G250 regulators:

  1. Prepare the Cylinder Valve: Before attaching the regulator, briefly open and close the cylinder valve (known as 'cracking' the valve) to blow out any dust or debris from the outlet. Stand to the side of the valve opening when doing this.
  2. Attach the Oxygen Regulator:
    Victor G250 Oxygen Regulator
    Image 4.1: Close-up of the Victor G250 Oxygen Regulator with its green adjustment knob and two gauges.
    Connect the Victor G250 Oxygen Regulator (green knob) to the oxygen cylinder valve. Ensure the threads align correctly (CGA 540 for oxygen). Hand-tighten first, then use an appropriate wrench to securely tighten the connection. Do not overtighten.
  3. Attach the Acetylene Regulator:
    Victor G250 Acetylene Regulator
    Image 4.2: Close-up of the Victor G250 Acetylene Regulator with its red adjustment knob and two gauges.
    Connect the Victor G250 Acetylene Regulator (red knob) to the acetylene cylinder valve. Ensure the threads align correctly (CGA 510 for acetylene). Hand-tighten first, then use an appropriate wrench to securely tighten the connection. Acetylene connections are typically left-hand threaded.
  4. Unganisha Hoses: Attach the appropriate hoses to the regulator outlets. Ensure all hose connections are tight and secure.
  5. Close Regulator Adjustment Knobs: Before opening the cylinder valves, turn the regulator adjustment knobs counter-clockwise until they feel loose. This ensures no pressure is applied to the system when the cylinder valve is opened.

5. Maagizo ya Uendeshaji

Follow these steps for safe operation of your Victor G250 regulators:

  1. Open Cylinder Valves: Slowly open the oxygen cylinder valve all the way. For acetylene, open the cylinder valve no more than 1.5 turns (or until the valve is fully open, whichever is less) to allow for quick shut-off in an emergency. The high-pressure gauge on each regulator will now show the cylinder pressure.
  2. Angalia Uvujaji: Apply a non-flammable leak detection solution to all connections (cylinder to regulator, regulator to hose). Look for bubbles, which indicate a leak. If a leak is detected, close the cylinder valve, relieve pressure, and re-tighten the connection. Repeat the leak test.
  3. Set Working Pressure: Slowly turn the regulator adjustment knob clockwise until the desired working pressure is indicated on the low-pressure gauge. Adjust gradually to avoid sudden pressure surges.
  4. Anza Kazi: Once the desired pressures are set and no leaks are present, you can begin your welding or cutting operation according to your equipment's instructions.
  5. Utaratibu wa Kuzima: When finished, first close the cylinder valves. Then, open the torch valves (or other downstream equipment) to bleed off all gas from the hoses and regulators until both regulator gauges read zero. Finally, turn the regulator adjustment knobs counter-clockwise until they are loose to release spring tension.

6. Matengenezo

Proper maintenance ensures the longevity and safe operation of your regulators.

7. Utatuzi wa shida

This section addresses common issues you might encounter with your regulators.

TatizoSababu inayowezekanaSuluhisho
No pressure reading on high-pressure gaugeCylinder valve closed or empty cylinderOpen cylinder valve fully (oxygen) or 1.5 turns (acetylene). Check cylinder contents.
No pressure reading on low-pressure gaugeRegulator adjustment knob not turned in (clockwise)Slowly turn adjustment knob clockwise to set desired working pressure.
Gas leak at connectionsLoose connection or damaged sealing surfaceClose cylinder valve, relieve pressure, re-tighten connection. Perform leak test. Inspect threads and sealing surfaces for damage.
Fluctuating delivery pressureCylinder pressure too low or internal regulator issueCheck cylinder pressure; replace if low. If problem persists, regulator may require professional servicing.

If you encounter issues not listed here or if solutions do not resolve the problem, discontinue use and contact a qualified technician or ESAB customer support.

8. Vipimo

Key specifications for the ESAB Victor G250 Series Regulators (Model 0781-3287):

Victor G250 Regulators Product Sheet
Image 8.1: Product sheet detailing features and specifications of Victor G250 Oxygen and Acetylene Regulators.
KipengeleMaelezo
MtengenezajiESAB
Nambari ya Sehemu0781-3287
Uzito wa Kipengee6.98 pounds (set)
Vipimo vya KifurushiInchi 9.25 x 9.25 x 9.06
Nambari ya Mfano wa Kipengee0781-3287 (G250 Series)
Aina ya MdhibitiMoja-stage
Oxygen Regulator ModelG250-150-540
Acetylene Regulator ModelG250-15-510
Cylinder Gas CompatibilityOxygen, Acetylene
Kipenyo cha kupimainchi 2 (milimita 50.8)

9. Udhamini na Msaada

For warranty information and customer support regarding your ESAB Victor G250 Series Regulators, please contact ESAB directly or refer to the official ESAB webtovuti. Masharti na masharti ya udhamini yanaweza kutofautiana kulingana na eneo na tarehe ya ununuzi.

You can visit the official ESAB store for more information: ESAB Store on Amazon

Nyaraka Zinazohusiana - G250

Kablaview ESAB TRACFINDER WHEEL: Betjeningsvejledning og Teknisk Habari
Denne betjeningsvejledning mtoaji detaljerede instruktioner til ufungaji, drift, vedligeholdelse og fejlfinding af ESAB TRACFINDER WHEEL svejsetraktor. Lær om tekniske specifikationer, sikkerhedsprocedurer na tilbehør.
Kablaview ESAB LAF 1001 / LAF 1001M Instruction Manual - Welding Power Source Guide
Comprehensive instruction manual for the ESAB LAF 1001 and LAF 1001M remote-controlled 3-phase welding power sources, covering installation, operation, maintenance, and safety for mechanised arc welding applications.
Kablaview Guía de funcionamiento del TRACFINDER WHEEL de ESAB
Manual de funcionamiento y guía de instalación para el carro de soldadura autónomo ESAB TRACFINDER WHEEL. Cubre especificaciones técnicas, operaciones, mantenimiento y solución de problemas.
Kablaview Mwongozo wa Maagizo ya ESAB Rogue ET 200iP PRO - Mwongozo wa Chanzo cha Nguvu za Kulehemu
Mwongozo wa kina wa chanzo cha nguvu cha kulehemu cha ESAB Rogue ET 200iP PRO. Inashughulikia usalama, usakinishaji, uendeshaji, matengenezo, utatuzi, na vipimo vya kiufundi kwa ajili ya programu za kulehemu za MMA na TIG.
Kablaview ESAB Caddy Mig C200i - Mwongozo wa Maagizo
Maelekezo kamili kwa ajili ya ESAB Caddy Mig C200i, ambayo yana uundaji wa tovuti yetu ya uuzaji wa MIG/MAG. Incluye información sobre instalación, operación, mantenimiento y solución de problemas.
Kablaview ESAB Savage A41 Welding Helmet Instruction Manual and Spare Parts List
Comprehensive instruction manual and spare parts list for the ESAB Savage A41 welding helmet. Learn about safety, operation, maintenance, and technical specifications for this auto-darkening welding helmet.