1. Utangulizi
This manual provides comprehensive instructions for the installation, operation, and maintenance of your 2GIG Z-Wave 700 Programmable Thermostat, Model 2GIG-STZ-1. This device allows for remote control of your heating and air conditioning systems via a Z-Wave network, in addition to direct control from the thermostat unit.
The 2GIG-STZ-1 thermostat is compatible with most modern HVAC systems, including standard Gas/Electric (2-stage inapokanzwa, 2-stage cooling) and Heat Pump systems (3-stage inapokanzwa, 2-stage cooling), with support for humidifiers and dehumidifiers.

Kielelezo 1: Mbele view of the 2GIG Z-Wave 700 Programmable Thermostat, displaying current temperature, fan status, and time.
Sifa Muhimu:
- Udhibiti wa Z-Wave: Seamless integration with smart home systems for remote access.
- Utangamano mwingi: Supports standard gas/electric, heat pump, and humidifier/dehumidifier systems.
- Ufungaji Rahisi: Designed for straightforward replacement of existing thermostats.
- Chanzo cha Nguvu mbili: Operates on 4 AA batteries or 24VAC power from your HVAC system.
- Onyesho la wazi: Large, easy-to-read LCD for temperature control and monitoring.
2. Taarifa za Usalama
Please read all instructions carefully before installing or operating this thermostat. Failure to follow these instructions could result in property damage, injury, or death.
- Usalama wa Umeme: Always turn off power to the HVAC system at the circuit breaker before installing or servicing the thermostat.
- Voltage Utangamano: This thermostat is designed for 24VAC systems only. It is NOT compatible with 120/240 VAC systems.
- Ufungaji wa Betri: If powering the thermostat via 24VAC, do not install AA batteries. Batteries are for backup power only if 24VAC is not available or desired.
- Ufungaji wa Kitaalamu: If you are unsure about any part of the installation process, consult a qualified HVAC technician.
3. Yaliyomo kwenye Kifurushi
Thibitisha kuwa vipengee vyote vipo kwenye kifurushi:
- 2GIG Z-Wave 700 Programmable Thermostat (Model 2GIG-STZ-1)
- 4 x Betri za AA
- Vifaa vya Kupachika (skrubu na nanga za ukutani)
- Mwongozo wa Usakinishaji (hati hii)
- Mwongozo wa Kuanza Haraka
4. Ufungaji
4.1. Kujiandaa kwa Ufungaji
- Turn off power to your heating and cooling system at the main circuit breaker.
- Remove your old thermostat's cover. Take a picture of the wiring connections for reference.
- Label each wire with the corresponding terminal letter from your old thermostat.
- Disconnect the wires and remove the old thermostat's mounting plate.
4.2. Mounting the Back Panel
The back panel of the 2GIG-STZ-1 thermostat serves as the mounting base and wiring terminal.
- Feed the wire cable from the wall through the access hole in the new mounting plate.
- Use the provided wall anchors and two Phillips screws to secure the back panel to the wall.
- Ensure the back panel is level for proper aesthetic alignment.

Figure 2: Illustration of mounting the back panel, showing wire access and screw locations.
4.3. Wiring thermostat
Connect the labeled wires to the corresponding terminals on the thermostat's back panel. Refer to your old thermostat's wiring diagram and the labels you made. The 2GIG-STZ-1 supports the following configurations:
- Standard Gas/Electric HVAC: Hadi 2-stage inapokanzwa, 2-stage baridi.
- Heat Pump HVAC: Hadi 3-stage inapokanzwa, 2-stage baridi.
- Humidifier/Dehumidifier Support: Dedicated terminals available.
For 24VAC power, ensure both "R" and "C" wires are connected. If a "C" wire is not available, the thermostat can be powered by 4 AA batteries, but it will not repeat Z-Wave signals in your network.
4.4. Kuunganisha Jopo la Mbele
Once wiring is complete, attach the thermostat's front panel to the mounted back panel.
- Align the front panel with the back panel.
- Gently press the front panel onto the back panel until it snaps securely into place around all edges.

Figure 3: Illustration of attaching the front panel to the back panel, showing the snap-together mechanism.
After the front panel is attached, restore power to your HVAC system at the circuit breaker.
5. Maagizo ya Uendeshaji
5.1. Powering the Thermostat
The thermostat can be powered by 24VAC from your HVAC system (if "R" and "C" wires are connected) or by four (4) AA batteries. If 24VAC is supplied, batteries are not required for operation but can serve as a backup. If only battery-powered, the thermostat will not function as a Z-Wave repeater.
5.2. Udhibiti wa Msingi
The thermostat features a clear LCD display and intuitive buttons for control:
- Kitufe cha SHABIKI: Cycles through fan modes (Auto, On).
- Kitufe cha MODE: Cycles through system modes (Heat, Cool, Auto, Off, Em Heat).
- Mishale ya Juu/Chini: Adjusts the temperature setpoint.
5.3. Kurekebisha Joto
Bonyeza kwa Up or Chini arrow buttons to increase or decrease the desired temperature setpoint. The display will show the new setpoint temporarily.
5.4. Z-Wave Network Integration
To integrate the thermostat into your Z-Wave network, refer to your Z-Wave hub's instructions for adding new devices. The 2GIG-STZ-1 is a Z-Wave 700 series device, offering enhanced range and battery life. Once paired, you can control the thermostat remotely via your Z-Wave smart device or hub interface.
Kumbuka: For optimal Z-Wave performance and to function as a Z-Wave repeater, the thermostat should be powered by 24VAC.
6. Matengenezo
6.1. Cleaning the Thermostat
Ili kusafisha kidhibiti cha halijoto, futa sehemu ya nje kwa upole na laini, damp cloth. Do not use abrasive cleaners, solvents, or spray cleaners directly onto the thermostat, as this may damage the unit or its electronic components.
6.2. Kubadilisha Betri
If your thermostat is battery-powered, replace the four (4) AA batteries when the low battery indicator appears on the display. Ensure to use fresh, high-quality alkaline batteries. If the thermostat is 24VAC powered, battery replacement is not typically required for operation, but batteries can be installed for backup power.
- Carefully remove the front panel of the thermostat from the back panel.
- Ondoa betri za zamani za AA.
- Ingiza betri nne mpya za AA, hakikisha polarity sahihi (+/-).
- Reattach the front panel to the back panel until it snaps securely.
7. Utatuzi wa shida
If you encounter issues with your 2GIG-STZ-1 thermostat, refer to the following common problems and solutions:
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| Thermostat has no power/blank display. | No 24VAC power; dead batteries; incorrect wiring. | Check circuit breaker for HVAC system. Replace AA batteries if battery-powered. Verify "R" and "C" wire connections. |
| HVAC system not responding to thermostat. | Incorrect wiring; system mode set to "Off"; Z-Wave communication issue. | Double-check wiring. Ensure system mode is set to "Heat", "Cool", or "Auto". Re-pair with Z-Wave network if controlling remotely. |
| Temperature swing is too wide. | Thermostat differential settings. | Consult the advanced settings menu (if available) or your Z-Wave controller for options to adjust temperature differential. This setting controls how far the temperature deviates from the setpoint before the system activates. |
| Cannot connect to Z-Wave network. | Thermostat too far from hub; interference; incorrect pairing procedure. | Ensure thermostat is within range of the Z-Wave hub or a repeater. Follow Z-Wave hub's specific instructions for inclusion/exclusion. Ensure thermostat is 24VAC powered to act as a repeater. |
8. Vipimo
| Kipengele | Maelezo |
|---|---|
| Nambari ya Mfano | 2GIG-STZ-1 (also known as 2GIG-STZ1-345) |
| Utangamano | 24VAC 3H/2C non-heat pump/heat pump systems with humidifier/dehumidifier support. Not compatible with 120/240 VAC systems. |
| Room Temperature Measurement Scale | Fahrenheit / Celsius (user selectable) |
| Kiwango cha Joto la Chumba | digrii 32 hadi 122 F (digrii 0 hadi 50 C) |
| Usahihi wa Joto | +/- 1 degrees F (0.5 degrees C) |
| Heat Set Point Range | 32 - 90 degrees F (0 - 32 degrees C) |
| Cool Set Point Range | 61 - 122 degrees F (16 - 50 degrees C) |
| Kuweka Azimio | Digrii 1 F (digrii 0.5 C) |
| Udhibiti wa Mashabiki | Otomatiki / Washa |
| Ugavi wa Nguvu | AC: 18-26VAC 60Hz (R and C); 4x AA size battery (6VDC) |
| Kiwango cha Joto la Uendeshaji | digrii 32 hadi 122 F (digrii 0 hadi 50 C) |
| Unyevu wa Uendeshaji | 10-90 percent Non-Condensing |
| Vipimo (H x W x D) | Inchi 5.75 x 4.5 x 1 (cm 14.6 x 11.4 x 2.5) |
| Uzito | Pauni 1.06 (kilo 0.48) |
| Muunganisho | Z-Wave (700 mfululizo) |
| Aina ya Kuonyesha | LCD na Mwangaza wa nyuma |
9. Taarifa za Udhamini
The 2GIG Z-Wave 700 Programmable Thermostat (Model 2GIG-STZ-1) comes with a Udhamini Mdogo wa Miaka 1 from the manufacturer. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty documentation included with your product or contact 2GIG customer support.
10. Msaada kwa Wateja
For further assistance, technical support, or warranty inquiries, please contact 2GIG customer support. You may also refer to the support resources provided by your Z-Wave hub manufacturer for integration-specific questions.
Kumbuka: Manufacturer support policies may vary. Access to detailed manuals or direct support might be restricted to authorized dealers or installers in some cases.