KING KB2405-1-ECO2S-PLUS

KING KB ECO2S+ 5KW 240V Electronic Garage Heater Instruction Manual

Model: KB2405-1-ECO2S-PLUS

Chapa: KING

1. Utangulizi

The KING KB ECO2S+ series unit heater provides efficient and user-friendly heating for various spaces. This model, KB2405-1-ECO2S-PLUS, features a 5KW / 240V power output, 2-stage heating, and an integrated electronic thermostat with a remote control and remote temperature sensor for optimal comfort and energy savings. It is designed for use as primary or supplemental heat sources in warehouses, stores, or large garages.

Sifa Muhimu:

2. Taarifa Muhimu za Usalama

Read all instructions before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.

3. Yaliyomo kwenye Kifurushi

Thibitisha kwamba vitu vyote vipo na havijaharibika unapofungua kifurushi:

KING KB ECO2S+ heater unit, remote control, remote temperature sensor, and mounting bracket
Figure 1: Included components of the KING KB ECO2S+ heater package.

This image displays the main heater unit, a black remote control, a white remote temperature sensor, and a grey universal mounting bracket, all included in the product package.

4. Ufungaji

4.1 Kuweka Hita

The universal mounting bracket allows for both wall and ceiling installation. Ensure the mounting surface is structurally sound to support the heater's weight (approximately 40 lbs). Use appropriate lag bolts or expansion bolts provided in the hardware pack.

  1. Attach the universal bracket to the desired wall or ceiling location using appropriate fasteners.
  2. Align the heater unit with the bracket and secure it using the large knobs on the sides, allowing for angle adjustment.
  3. Adjust the heater angle to direct airflow as needed. The bracket offers four adjustable positions.
Nyuma view of KING KB ECO2S+ heater showing the fan and mounting points
Kielelezo cha 2: Nyuma view of the heater, illustrating the fan and mounting points for the bracket.

This image shows the back of the grey heater unit with a protective grill covering the fan. Mounting holes are visible on the sides for attaching the universal bracket.

4.2 Wiring za Umeme

This heater requires a 240V dedicated circuit. Installation must be performed by a licensed electrician. The 5KW model typically requires a 40-amp breaker and 4-8 AWG copper wire. Ensure all local electrical codes are followed.

  1. Ondoa Nguvu: Turn off power at the main circuit breaker before beginning any wiring.
  2. Sehemu ya Kuunganisha Waya: Locate and remove the single Phillips screw on the side panel to open the wiring compartment.
  3. Remove Knockout: Select an appropriate knockout on the side of the heater for your wiring. Use pliers to remove the knockout.
  4. Install Strain Relief: Insert the provided grommet with integral strain relief into the knockout hole.
  5. Unganisha Waya:
    • Connect the black wire to the L1 terminal.
    • Connect the red wire to the L2 terminal.
    • Connect the green (ground) wire to the grounding screw.
    Ensure all wires are securely tightened and that no insulation is under the terminals.
  6. Wiring Salama: Tighten the strain relief to prevent the wire from pulling out and to protect the wiring from damage.
  7. Funga Sehemu: Reattach the access panel with the Phillips screw.
  8. Rejesha Nguvu: Washa umeme kwenye kivunja mzunguko mkuu.
Internal wiring compartment of the KING KB ECO2S+ heater showing terminals and circuit board
Figure 3: Internal wiring connections for the heater.

This image shows the internal wiring compartment of the heater with various colored wires connected to terminals (L1, L2, and ground) and a circuit board. A label indicates "Red Wire L2" and "Black Wire L1" for 240V, 4-8AWG connections.

Video 1: This video demonstrates the electrical wiring process for the KING KB ECO2S+ heater, showing how to connect the power cable to the internal terminals and secure it with a strain relief. It also highlights the 2-stage heating feature and remote temperature sensing.

4.3 External Thermostat Switch

On the back of the heater, there is a toggle switch to select between the built-in thermostat (setting I) and an external thermostat (setting II). For most applications using the integrated controls, ensure the switch is set to 'I'. If connecting to an external 24V thermostat (e.g., Nest), set the switch to 'II' and ensure proper wiring by a licensed electrician.

5. Maagizo ya Uendeshaji

5.1 Kuongeza Nguvu kwa Awali

Upon initial power-up, the unit will beep, and the display will show the current room temperature. This indicates correct voltage na usambazaji wa umeme.

5.2 Jopo la Kudhibiti na Kidhibiti cha Mbali

The heater can be operated via the integrated control panel or the included remote control. The remote control offers convenient access to all functions from a distance.

Mbele view of KING KB ECO2S+ heater showing the control panel
Kielelezo 4: Mbele view of the heater with the control panel visible.

This image shows the front of the grey heater unit with horizontal louvers and a digital control panel at the bottom. The control panel has buttons for Power, Mode, Start/Stop, and Up/Down arrows, along with a digital temperature display.

5.3 Njia za Uendeshaji

Press the 'Mode' button to cycle through the available operating modes:

5.4 Mpangilio wa Joto

Use the Up/Down arrow buttons on the control panel or remote to set your desired temperature. The heater will maintain this temperature automatically.

5.5 Kazi ya Kipima saa

The timer mode allows you to set the heater to run for a predetermined length of time, after which it will automatically shut off. This feature helps conserve energy and provides convenience.

6. Matengenezo

Matengenezo ya mara kwa mara huhakikisha utendaji bora na uimara wa hita yako. Daima ondoa umeme kabla ya kufanya matengenezo yoyote.

7. Utatuzi wa shida

If your heater is not functioning correctly, refer to the following common issues and solutions:

TatizoSababu inayowezekanaSuluhisho
Heater does not turn on / No display.No power to the unit or incorrect voltage.Check circuit breaker. Ensure 240V power is supplied. Verify wiring connections are secure.
Hita imewashwa lakini haitoi joto.Thermostat switch set to external, or external thermostat not calling for heat.Ensure the external thermostat switch on the back of the unit is set to 'I' for internal thermostat control. If using an external thermostat, check its settings.
Inapokanzwa haitoshi.Incorrect mode selected, or obstructions.Select 'High Heat' mode. Ensure air inlets/outlets are clear. Check louvers are directed appropriately.
Udhibiti wa mbali haufanyi kazi.Betri zilizokufa au kizuizi.Badilisha betri za udhibiti wa mbali. Hakikisha hakuna vizuizi kati ya udhibiti wa mbali na hita.

8. Vipimo

Chart showing recommended garage heater wattage for different garage sizes
Figure 5: Recommended wattage for various garage sizes.

This chart provides guidance on selecting the appropriate heater wattage based on garage size (1-car to 4-car garages), square footage, BTU, CFM, and amperage. The 5KW model is suitable for 1-car garages up to 450 sq. ft.

9. Udhamini na Msaada

For specific warranty details, please refer to the documentation included with your product or contact KING customer support. General product protection plans may be available for purchase separately.

Visit the official KING Store for more information: KING Store

Nyaraka Zinazohusiana - KB2405-1-ECO2S-PLUS

Kablaview Hita ya King KBP ECO2S+ Series Compact Unit - 2-S Inayotumia Nishati Vizuritage Inapokanzwa
Maelezo ya kina kuhusu hita ndogo ya kitengo cha King KBP ECO2S+ Series, yenye udhibiti wa kielektroniki wa ECO2S+ unaookoa nishati, sekunde 2tagInapokanzwa kwa njia ya kielektroniki, utambuzi wa halijoto kwa mbali, na chaguo mbalimbali za usakinishaji. Inajumuisha vipimo, taarifa za kuagiza, na maelezo ya uhandisi.
Kablaview Mwongozo wa Ufungaji na Matengenezo ya Hita ya King LPW-ECO Series
Mwongozo wa kina wa kusakinisha, kuendesha na kudumisha hita za mfululizo za King LPW-ECO, ikijumuisha maagizo ya usalama, michoro ya nyaya, usanidi wa kihisi cha mbali na utatuzi wa matatizo.
Kablaview Mwongozo wa Usakinishaji na Utunzaji wa King LPW ECO2S PRO kwa kutumia Kidhibiti Mahiri
This comprehensive manual provides detailed instructions for the installation, maintenance, and operation of the King LPW ECO2S PRO series electric heaters. Learn about safe installation, programming the 7-day ECO PRO controller, wiring, troubleshooting, and warranty information for optimal comfort and energy savings.
Kablaview Mwongozo wa Ufungaji na Uendeshaji wa Kidhibiti Kinachoweza Kupangwa cha King PX ECO2S PRO cha Siku 7
Mwongozo kamili wa King PX ECO2S PRO 2-S zinazoweza kupangwa kwa siku 7tagKidhibiti cha Kielektroniki chenye Kipimo cha Joto cha Mbali. Kinajumuisha maagizo ya usalama, usakinishaji, nyaya za umeme, na majitaguteuzi wa kielektroniki, kuoanisha kidhibiti, usanidi, hali za uendeshaji, programu, utatuzi wa matatizo, matengenezo, na ujumuishaji wa hiari wa vitambuzi.
Kablaview Hita ya King LPW ECO2S PRO: Mwongozo wa Usakinishaji, Matengenezo, na Uendeshaji
Mwongozo kamili wa King LPW ECO2S PRO 2-S zinazoweza kupangwa kwa siku 7tagHita ya Kielektroniki yenye Kidhibiti cha Kutambua Halijoto kwa Mbali. Hufunika usakinishaji, nyaya, na majitaguteuzi wa kielektroniki, usanidi, uendeshaji, matengenezo, utatuzi wa matatizo, na taarifa za udhamini.
Kablaview Hita ya Duka Inayobebeka ya King PSH2440TB: Mwongozo wa Usakinishaji, Uendeshaji, na Usalama
Mwongozo huu kamili hutoa taarifa muhimu kwa ajili ya Hita ya Duka Inayoweza Kubebeka ya King PSH2440TB, ikijumuisha usakinishaji, miongozo ya usalama, maagizo ya uendeshaji, vidokezo vya matengenezo, na suluhisho za utatuzi wa matatizo. Imeundwa kwa matumizi ya gereji na karakana, ina nguvu ya 3750W na uendeshaji wa 240V.