1. Utangulizi
Welcome to the user manual for the Vertiv GXT5 72V External Battery Cabinet 48V (Model: GXT5-EBC48VRT2U). This manual provides essential information for the safe and efficient installation, operation, and maintenance of your external battery cabinet. Please read this manual thoroughly before using the product and retain it for future reference.
The Vertiv GXT5 External Battery Cabinet is designed to extend the runtime of compatible Vertiv GXT5 Uninterruptible Power Supply (UPS) systems, providing critical backup power during outages.
2. Taarifa Muhimu za Usalama
WARNING: Risk of electric shock. Do not remove cover. Refer servicing to qualified personnel only.
- Always disconnect the battery cabinet from the UPS and power source before performing any maintenance or service.
- Do not attempt to open or service the battery cabinet. There are no user-serviceable parts inside.
- Ensure proper grounding of the UPS system and the battery cabinet.
- Avoid installing the unit in areas with excessive heat, humidity, or dust.
- Usizuie fursa za uingizaji hewa.
- Use only specified cables and connectors provided with the unit or approved by Vertiv.
- Batteries can present a risk of electrical shock and high short-circuit current. Observe the following precautions when working on batteries:
- Ondoa saa, pete au vitu vingine vya chuma.
- Tumia zana zilizo na vipini vya maboksi.
3. Bidhaa Imeishaview
3.1 Vipengele
- External 48V UPS battery cabinet provides extended runtime during an outage.
- Compatible with Liebert GXT5-1500LVRT2UXL (1500 VA) and Liebert GXT5-2000LVRT2UXL (2000 VA) UPS systems.
- Auto detection connectivity ensures proper set-up and configuration of available run time.
- Compact 2U rack mounted design.
- Includes external temperature compensation sensors that extend battery life.
3.2 Vipengele

Kielelezo cha 3.2.1: Kuu view of the Vertiv GXT5 External Battery Cabinet. This image shows the overall sleek, black design of the 2U rack-mountable unit with the Vertiv logo prominently displayed on the front grille.

Kielelezo 3.2.2: Mbele view of the Vertiv GXT5 External Battery Cabinet. This image highlights the front panel with its distinctive honeycomb grille pattern and the Vertiv branding.

Kielelezo cha 3.2.3: Nyuma view of the Vertiv GXT5 External Battery Cabinet. This image displays the various ports and connectors, including the battery connector, EBC count switches, and the temperature sensor port, along with safety warnings.

Kielelezo 3.2.4: Juu view of the Vertiv GXT5 External Battery Cabinet. This image provides an overhead perspective, showing the smooth top surface and the overall compact form factor of the unit.
4. Kuweka na Kuweka
4.1 Kufungua
- Carefully unpack the external battery cabinet from its packaging.
- Kagua kitengo hicho kwa dalili zozote za uharibifu ambazo huenda zimetokea wakati wa usafirishaji. Uharibifu ukipatikana, wasiliana na muuzaji wako mara moja.
- Thibitisha kuwa vipengele vyote vilivyoorodheshwa kwenye orodha ya vifungashio vipo.
4.2 Uwekaji
- The GXT5-EBC48VRT2U is designed for indoor use only.
- Place the battery cabinet in a clean, dry area, away from direct sunlight, heat sources, and excessive moisture.
- Ensure adequate airflow around the unit to prevent overheating. Maintain at least 2 inches (5 cm) of clearance on all sides.
- The unit can be rack-mounted or placed on a stable, flat surface.
4.3 Connecting the External Battery Cabinet
- Ensure the compatible Vertiv GXT5 UPS system is turned off and disconnected from the AC power source.
- Locate the external battery connector port on the rear of the UPS.
- Connect the battery cable from the external battery cabinet to the corresponding port on the UPS. Ensure the connection is secure. Refer to Figure 3.2.3 for the location of the battery connector on the EBC.
- If connecting multiple external battery cabinets (up to 6), connect them in series using the provided communication cables.
- The new auto-detection feature will automatically configure the UPS to recognize the connected battery cabinet(s), ensuring proper setup and accurate runtime calculation.
- Once connected, you may power on the UPS system.
5. Maagizo ya Uendeshaji
5.1 Kuongeza Nguvu kwa Awali
After connecting the external battery cabinet to the UPS, power on the UPS system according to its specific user manual. The UPS will automatically detect the connected battery cabinet(s) and adjust its runtime calculations accordingly.
5.2 Ufuatiliaji
Monitor the battery status and runtime information through the UPS display or management software. The added battery capacity from the external cabinet will be reflected in the UPS's reported runtime.
5.3 Extending Runtime
The primary function of the GXT5-EBC48VRT2U is to provide extended runtime for your connected equipment during a power outage. When the UPS switches to battery mode, the external battery cabinet will seamlessly provide additional power, allowing for longer operation or a more graceful shutdown of critical systems.
6. Matengenezo
6.1 Utunzaji wa Betri
- The GXT5-EBC48VRT2U utilizes lead-acid batteries. These batteries are designed for long life, especially with the integrated external temperature compensation sensors that help optimize charging based on ambient temperature.
- Avoid frequent deep discharges, as this can shorten battery life.
- Ensure the battery cabinet is kept in a well-ventilated area to prevent heat buildup, which can degrade battery performance.
- Battery replacement should only be performed by qualified service personnel.
6.2 Kusafisha
Periodically clean the exterior of the battery cabinet with a soft, dry cloth. Do not use liquid or aerosol cleaners, as they may damage the unit or pose an electrical hazard.
6.3 Hifadhi
If the battery cabinet is to be stored for an extended period, ensure it is fully charged and stored in a cool, dry place. It is recommended to recharge the batteries every 3-6 months to prevent deep discharge and maintain battery health.
7. Utatuzi wa shida
This section provides solutions to common issues you might encounter with your Vertiv GXT5 External Battery Cabinet. For problems not listed here, please contact Vertiv customer support.
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| External Battery Cabinet not detected by UPS. | Uunganisho wa kebo iliyolegea au isiyo sahihi. | Ensure the battery cable is securely connected to both the EBC and the UPS. Verify the correct port is used. |
| Reduced or no extended runtime. | Batteries not fully charged or nearing end of life. | Allow the UPS to charge the batteries for at least 24 hours. If the issue persists, contact Vertiv support for battery health assessment. |
| Overheating of the unit. | Blocked ventilation or high ambient temperature. | Ensure adequate clearance around the unit. Relocate to a cooler environment if necessary. |
8. Vipimo
8.1 Maelezo ya Kiufundi
| Sifa | Thamani |
|---|---|
| Nambari ya Mfano | GXT5-EBC48VRT2U |
| Vipimo vya Bidhaa (L x W x H) | Inchi 18.6 x 16.9 x 3.3 |
| Uzito wa Kipengee | Pauni 58.9 |
| Muundo wa Kiini cha Betri | Asidi ya risasi |
| Voltage | 48 Volts |
| Rangi | Nyeusi |
| Nyenzo | Chuma |
| Mtengenezaji | Vertiv |
| Nchi ya Asili | China |
| Tarehe ya Kwanza Inapatikana | Juni 5, 2019 |
9. Udhamini na Msaada
9.1 Taarifa ya Udhamini
The Vertiv GXT5-EBC48VRT2U External Battery Cabinet comes with a dhamana ya miaka mitatu ya kiwanda. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the documentation included with your product or visit the official Vertiv webtovuti.
9.2 Usaidizi kwa Wateja
For technical assistance, troubleshooting, or warranty inquiries, please contact Vertiv customer support. You can find contact information and additional resources by visiting the Duka la Vertiv kwenye Amazon au Vertiv rasmi webtovuti.





