AERMEC SLG350W

AERMEC SLG350W Inverter Air Conditioner User Manual

Model: SLG350W

1. Utangulizi

Thank you for choosing the AERMEC SLG350W Inverter Air Conditioner. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air conditioning system. Please read this manual thoroughly before using the appliance and keep it for future reference.

The AERMEC SLG350W is a 3.5 KW (12000 BTU) Inverter Split System Air Conditioner designed for optimal cooling and heating performance, utilizing R32 gas for improved environmental efficiency.

2. Taarifa za Usalama

Fuata tahadhari za kimsingi za usalama kila wakati unapotumia vifaa vya umeme ili kupunguza hatari ya moto, mshtuko wa umeme na majeraha.

3. Bidhaa Imeishaview

The AERMEC SLG350W is a split-system air conditioner consisting of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical wiring. It features inverter technology for energy efficiency and precise temperature control.

Aermec SLG350W Indoor and Outdoor Units with Remote Control

Kielelezo cha 3.1: Zaidiview of the Aermec SLG350W air conditioner system, showing the indoor unit, outdoor unit, and remote control. The indoor unit is a sleek white rectangular shape, and the outdoor unit is a compact, white rectangular box with a fan grille.

Aermec SLG350W Air Conditioner with R32 Gas and Inverter Logos

Kielelezo cha 3.2: karibu zaidi view of the Aermec SLG350W air conditioner, highlighting its R32 refrigerant and Inverter technology. This image shows the indoor unit, outdoor unit, and remote control, with additional graphical icons indicating R32 gas, cooling/heating functions, monosplit system, and inverter technology.

Sifa Muhimu:

4. Kuweka na Kuweka

Installation of the AERMEC SLG350W split system air conditioner requires specialized tools and knowledge. It is mandatory that installation be performed by a certified and qualified HVAC technician. Improper installation can lead to refrigerant leaks, electrical hazards, and damage to the unit, voiding the warranty.

4.1 Hundi za Kusakinisha Kabla

4.2 Uwekaji wa Kifaa cha Ndani

4.3 Uwekaji wa Kitengo cha Nje

4.4 Viunganishi vya Umeme

All electrical wiring must comply with local codes and regulations. A dedicated circuit breaker is recommended.

4.5 Refrigerant Piping and Drainage

Proper vacuuming of the refrigerant lines is crucial before charging the system. Ensure the condensate drain line is sloped correctly to allow for continuous drainage.

5. Maagizo ya Uendeshaji

Your AERMEC SLG350W air conditioner is operated primarily via the included remote control.

5.1 Kazi za Udhibiti wa Mbali

Kidhibiti cha mbali hukuruhusu kurekebisha mipangilio anuwai:

5.2 Njia za Uendeshaji

5.3 Wi-Fi Control (Optional)

If you have purchased and installed the optional WIFIKIT10, you can control your air conditioner remotely using a dedicated smartphone or tablet application. Refer to the Wi-Fi kit's separate instructions for setup and usage.

6. Matengenezo

Matengenezo ya mara kwa mara huhakikisha utendakazi bora na huongeza maisha ya kiyoyozi chako. Ondoa umeme kila wakati kabla ya kufanya matengenezo yoyote.

6.1 Air Filter Cleaning (Indoor Unit)

The prefilter should be cleaned every two weeks or more frequently depending on usage and air quality.

  1. Fungua jopo la mbele la kitengo cha ndani.
  2. Ondoa vichungi vya hewa.
  3. Clean the filters with a vacuum cleaner or wash them with lukewarm water (below 40°C).
  4. Allow the filters to dry completely in a shaded area before reinstalling.
  5. Funga jopo la mbele.

6.2 Usafi wa Sehemu za Nje

Periodically clean the outdoor unit's coil and fan blades to remove dust, leaves, and debris. This should ideally be done by a professional technician during annual servicing.

6.3 Ukaguzi wa Msimu

7. Utatuzi wa shida

Kabla ya kuwasiliana na huduma, angalia maswala na suluhisho zifuatazo za kawaida:

TatizoSababu inayowezekanaSuluhisho
Kitengo hakianzaNo power; Remote control batteries low; Timer set.Check power supply/breaker; Replace batteries; Cancel timer setting.
Upungufu wa baridi / inapokanzwaDirty air filter; Obstruction at air inlet/outlet; Temperature setting incorrect; Room too large.Clean air filter; Remove obstruction; Adjust temperature; Consult technician for proper sizing.
Uvujaji wa maji kutoka kwa kitengo cha ndaniDrain hose clogged or kinked; Improper installation.Check and clear drain hose; Contact qualified technician for inspection.
Kelele isiyo ya kawaidaSehemu zilizolegea; Kizuizi cha feni; Tatizo la compressor.Turn off unit and inspect for loose parts; Contact qualified technician.

If the problem persists after attempting these solutions, please contact a qualified service technician. Do not attempt to repair the unit yourself.

8. Vipimo

Technical specifications for the AERMEC SLG350W Inverter Air Conditioner:

KipengeleThamani
Nambari ya MfanoSLG350W
Uwezo wa Kupoa3.2 kW (12000 BTU)
Uwezo wa Kupokanzwa3.5 kW
Matumizi ya Nguvu (Kupoeza)1.0 kW
Matumizi ya Nguvu (Kupasha Joto)1.0 kW
Darasa la Ufanisi wa Nishati (Kupoa)A++
Darasa la Ufanisi wa Nishati (Kupasha joto)A+
SEER (Uwiano wa Ufanisi wa Nishati ya Msimu)6.1
SCOP (Mgawo wa Utendaji wa Msimu)4.0
Aina ya jokofuR32
Njia ya UfungajiKugawanya Mfumo
Vipengele MaalumInverter Compressor, Wi-Fi Ready (with optional kit)
Aina ya KichujioMtangulizi

9. Udhamini na Msaada

9.1 Taarifa ya Udhamini

The AERMEC SLG350W air conditioner comes with a limited warranty. Please refer to the warranty card included with your product for specific terms, conditions, and duration. Keep your purchase receipt as proof of purchase for warranty claims.

9.2 Usaidizi kwa Wateja

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact AERMEC customer support or your authorized dealer.

Please visit the official AERMEC website for the most up-to-date contact information and service center locations.

Nyaraka Zinazohusiana - SLG350W

Kablaview AERMEC SLG Serie Installationshandbuch | Klimaanlagen Installation & Wartung
Umfassendes Installationshandbuch für AERMEC SLG Serie Split-Klimaanlagen (200W-700W). Enthält detaillierte Anleitungen zur Installation, Wartung, Fehlerbehebung und technische Daten für Modelle wie SLG200W, SLG250W, SLG350W, SLG500W, SLG700W.
Kablaview AERMEC FK260 FK360 Use and Installation Manual
Comprehensive guide for the installation, operation, and maintenance of AERMEC FK260 and FK360 air conditioning units, covering safety, features, technical specifications, and troubleshooting.
Kablaview Mwongozo wa Mtumiaji wa Kiyoyozi cha AERMEC CMP231
Mwongozo wa kina wa mtumiaji wa kiyoyozi cha AERMEC CMP231, uendeshaji wa kufunika, maonyo, utatuzi, data ya kiufundi na taratibu za matengenezo.
Kablaview Mwongozo wa Mtumiaji wa Kidhibiti cha Mbali cha AERMEC
Mwongozo wa kina wa mtumiaji wa kidhibiti cha mbali cha AERMEC, unaoelezea vipengele vyote vya utendaji, utendakazi na mipangilio ya kitengo chako cha hali ya hewa, ikijumuisha uteuzi wa hali, kasi ya feni, vipima muda na vipengele maalum.
Kablaview Pampu za Joto za AERMEC SRP: Kiufundi, Ufungaji, na Mwongozo wa Matengenezo
Mwongozo wa kina wa pampu za joto za AERMEC SRP, unaoeleza kwa kina vipimo vya kiufundi, taratibu za usakinishaji, vikomo vya uendeshaji, na miongozo ya matengenezo ya utendakazi bora na maisha marefu. Inashughulikia mifano ya SRP 10, SRP 14M, SRP 14T, na SRP 19.
Kablaview Manuale Utente Telecomando AERMEC WLRC
Guida completa all'uso del telecomando AERMEC WLRC per condizionatori d'aria, con spiegazioni dettagliate delle funzioni, modalità operative, impostazioni e icone del display.