1. Bidhaa Imeishaview
The Uponor Smatrix Base T-145 is a wired digital room thermostat designed for precise temperature control in heating and cooling systems, particularly underfloor heating. It directly transmits measured values to the Smatrix Base X-145 control module, ensuring efficient and responsive climate management. This thermostat features a clear digital display for easy temperature adjustment and monitoring.

Picha 1.1: Mbele view of the Uponor Smatrix Base T-145 Wired Room Thermostat, showing its square white casing and central rotary dial for temperature adjustment. The 'Uponor' logo is visible at the bottom left.
2. Sifa Muhimu
- Digital Temperature Setting: Allows precise adjustment of the desired room temperature.
- Onyesho la Toleo la Programu: Shows the software version upon startup.
- Skrini yenye Mwangaza Nyuma: The display illuminates for 10 seconds after activation for improved visibility.
- Heating/Cooling Indicator: Clearly displays the current operating mode.
- Setback Function: Enables energy-saving temperature reduction during unoccupied periods.
- Setback Temperature Display: Shows the active setback temperature.
- Uteuzi wa Kitengo cha Halijoto: Badili kati ya Selsiasi na Fahrenheit.
- Onyesho la Hali ya Betri: Indicates the status of any internal backup battery or connected sensor batteries.
- Flexible Sensor Options: Supports room temperature (RT), floor sensor with max/min limits (FT), remote sensor (FS), and outdoor sensor (RO) inputs.
- Individual Room Cooling: Capable of managing cooling functions on a room-by-room basis.
3. Maelezo ya kiufundi
| Chapa | Juu |
| Nambari ya Mfano | 1086974 |
| Rangi | Nyeupe (RAL 9016) |
| Vipimo (H x W x D) | 80 x 80 x 26.5 mm |
| Uzito wa Kipengee | gramu 120 |
| Ugavi wa Nguvu | 4-wire bus (Wired) |
| Voltage | 24 Volts |
| Teknolojia ya Uunganisho | Wired |
| Darasa la Ulinzi | IP 30 |
| Kuzingatia | CE |
| Aina ya Kidhibiti | Udhibiti wa Mwongozo |
| Aina ya Udhibiti wa Joto | Dijitali |
| Matumizi Maalum | Inapokanzwa Underfloor |
| Vipengee vilivyojumuishwa | Room thermostat and mounting hardware |
4. Taarifa za Usalama
Please read and understand all safety instructions before installing or operating this device. Failure to follow these instructions may result in electric shock, fire, or property damage.
- Usalama wa Umeme: Installation must be performed by a qualified electrician in accordance with local electrical codes and regulations. Ensure power is disconnected at the main circuit breaker before any wiring work.
- Masharti ya Mazingira: Do not expose the thermostat to direct water spray, excessive humidity, or extreme temperatures outside its operating range. The device has an IP30 protection rating, meaning it is protected against solid objects over 2.5mm but not against water.
- Matumizi Yanayokusudiwa: This thermostat is designed for controlling heating and cooling systems. Do not use it for purposes other than its intended function.
- Kusafisha: Tumia kitambaa laini na kavu kwa kusafisha. Usitumie visafishaji vya abrasive au vimumunyisho.
5. Ufungaji na Usanidi
The Uponor Smatrix Base T-145 thermostat is a wired device requiring connection to an Uponor Smatrix Base X-145 control module via a 4-wire bus system. Professional installation is recommended.
5.1 Kuweka
- Kukatwa kwa Nguvu: Ensure the main power supply to the heating/cooling system is turned off at the circuit breaker before beginning installation.
- Uteuzi wa Mahali: Choose an indoor location on an interior wall, away from direct sunlight, drafts, and heat sources (e.g., lamps, appliances) that could affect temperature readings. Mount at a standard thermostat height (approximately 1.5 meters from the floor).
- Wiring: Connect the 4-wire bus cable from the Smatrix Base X-145 control module to the designated terminals on the T-145 thermostat. Refer to the wiring diagram provided with the Smatrix Base X-145 control module for specific terminal assignments.
- Uwekaji salama: Use the provided mounting hardware to securely attach the thermostat to the wall.
5.2 Usanidi wa Awali
- Washa: Restore power to the system at the circuit breaker. The thermostat display should illuminate.
- Software Version Check: Upon initial power-up, the software version will briefly display.
- Kitengo cha Joto: If necessary, adjust the temperature unit between Celsius and Fahrenheit according to the operating instructions in Section 6.
- Usanidi wa Sensor: If using optional floor, remote, or outdoor sensors, ensure they are correctly connected and configured within the Smatrix Base X-145 control module. The thermostat can display readings from these sensors.
6. Uendeshaji
The Uponor Smatrix Base T-145 thermostat provides straightforward control over your room's temperature.
6.1 Kuweka Joto
- Rotate the central dial clockwise to increase the desired temperature.
- Rotate the central dial counter-clockwise to decrease the desired temperature.
- The digital display will show the set temperature. The backlight will activate for 10 seconds after adjustment.
6.2 Onyesha Habari
- Halijoto ya Sasa: The main display shows the current room temperature.
- Weka Joto: Briefly displayed when adjusting the dial.
- Hali ya Uendeshaji: An icon or text indicates if the system is currently heating or cooling.
- Setback Indicator: If the setback function is active, an indicator will show, along with the setback temperature.
- Hali ya Betri: Displays the status of any internal backup battery or connected sensor batteries.
6.3 Changing Temperature Units (Celsius/Fahrenheit)
Specific instructions for changing temperature units are typically found in the main Smatrix Base X-145 control module manual or accessed via a combination of button presses on the thermostat. Consult the comprehensive system manual for detailed steps.
7. Matengenezo
The Uponor Smatrix Base T-145 thermostat requires minimal maintenance to ensure optimal performance.
- Kusafisha: Periodically wipe the thermostat's exterior with a soft, dry, or slightly damp kitambaa. Usitumie kemikali kali, visafishaji vya kukwaruza, au unyevu kupita kiasi.
- Ukaguzi wa Sensor: If using external sensors (floor, remote, outdoor), ensure they are free from obstructions and debris that could affect their readings.
- Ukaguzi wa Mfumo: Regularly check the overall heating/cooling system for proper operation as per the Smatrix Base X-145 control module manual.
8. Utatuzi wa shida
If you encounter issues with your Uponor Smatrix Base T-145 thermostat, refer to the following common problems and solutions:
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| Onyesho ni tupu au halijibu. | No power to the thermostat or control module. | Check the main power supply and circuit breaker. Ensure the 4-wire bus connection is secure. |
| Usomaji usio sahihi wa halijoto. | Eneo la kiyoyozi linaloathiriwa na rasimu, jua moja kwa moja, au vyanzo vya joto. | Relocate the thermostat if possible, or shield it from interfering elements. Ensure no external sensors are faulty or obstructed. |
| Mfumo wa kuongeza joto/upoeshaji haufanyi kazi. | Communication issue with Smatrix Base X-145 control module or system fault. | Verify the 4-wire bus connection. Check the Smatrix Base X-145 control module for error indicators. Consult the Smatrix Base X-145 manual for system-level troubleshooting. |
| Setback function not working as expected. | Incorrect configuration in the Smatrix Base X-145 control module. | Review the setback schedule and settings within the Smatrix Base X-145 control module. |
If the problem persists after attempting these solutions, contact Uponor customer support or a qualified HVAC technician.
9. Udhamini na Msaada
For warranty information, technical support, or service inquiries regarding your Uponor Smatrix Base T-145 Wired Room Thermostat, please refer to the documentation included with your complete Uponor Smatrix system or visit the official Uponor webtovuti. Weka uthibitisho wako wa ununuzi kwa madai ya udhamini.
Mtengenezaji: Juu
Nambari ya Mfano: 1086974
ASIN: B077CLZPJ8