Mwongozo wa Mtumiaji wa Microlife AFIB Advanced Easy Blood Pressure Monitor

Mfano: 70265

1. Utangulizi

The Microlife AFIB Advanced Easy Blood Pressure Monitor is designed for accurate blood pressure measurement and early detection of Atrial Fibrillation (AF) at home. AF is a common heart arrhythmia that can lead to serious health complications, including stroke. This device utilizes patented Microlife AFIB Technology to screen for AF during routine blood pressure measurements, offering high sensitivity (97-100%) and specificity (89%) as clinically validated. Regular monitoring can assist in early diagnosis and management of hypertension and AF.

2. Taarifa za Usalama

  • Consult your physician before using this device if you have any medical conditions or are pregnant.
  • Do not self-diagnose or self-medicate based on measurements. Always follow your doctor's advice.
  • This device is intended for home use and is not a substitute for professional medical examination.
  • Weka kifaa mbali na watoto na kipenzi.
  • Do not use the device in a moving vehicle or on an airplane.
  • Avoid strong electromagnetic fields (e.g., mobile phones) near the device during use.

3. Yaliyomo kwenye Kifurushi

Tafadhali hakikisha kuwa vipengele vyote vipo na havijaharibiwa:

  • Microlife AFIB Advanced Easy Blood Pressure Monitor unit
  • Conical pre-formed cuff (size 22-42 cm)
  • Mfuko wa usafiri
  • Betri za AAA 4 x 1.5V
  • User manual (multi-language)

4. Bidhaa Imeishaview

Familiarize yourself with the main components of your blood pressure monitor.

Microlife AFIB Advanced Easy Blood Pressure Monitor, cuff, and batteries

Image 1: The Microlife AFIB Advanced Easy Blood Pressure Monitor unit, conical cuff, and included AAA batteries.

Microlife conical cuff with arm placement diagram

Image 2: Close-up of the conical cuff, showing the Microlife logo, size range (22-42cm), and a diagram for correct arm placement.

Microlife transport bag

Image 3: The black transport bag with the Microlife logo, designed for convenient storage and portability of the monitor and cuff.

Microlife transport bag with dimensions

Image 4: The transport bag with an overlay indicating its dimensions, approximately 8.3 inches (21 cm) in height.

5. Kuweka

5.1. Ufungaji wa Betri

  1. Fungua kifuniko cha sehemu ya betri nyuma ya kidhibiti.
  2. Insert the four 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  3. Funga kifuniko cha sehemu ya betri kwa usalama.
Betri nne za AAA

Image 5: Four AAA alkaline batteries, typically included with the device for initial use.

5.2. Muunganisho wa Vifungo

Connect the air tube from the cuff to the air socket located on the side of the blood pressure monitor unit. Ensure a firm connection.

6. Maagizo ya Uendeshaji

6.1. Maandalizi ya Kipimo

  • Avoid eating, smoking, or exercising for at least 30 minutes before measurement.
  • Rest in a calm environment for 5 minutes before taking a measurement.
  • Sit comfortably with your back supported, feet flat on the floor, and legs uncrossed.
  • Place your arm on a flat surface so that the cuff is at heart level.

6.2. Cuff Placement

  1. Ensure the cuff is placed directly on bare skin, not over clothing.
  2. Wrap the cuff around your upper arm, approximately 2 cm above the elbow.
  3. The artery mark on the cuff (usually an arrow) should align with your brachial artery, which runs along the inside of your arm.
  4. Tighten the cuff so it is snug but not uncomfortably tight. You should be able to fit two fingers underneath.

6.3. Taking a Measurement (MAM Technology)

The Microlife AFIB Advanced Easy monitor features MAM (Microlife Average Mode) technology, which automatically takes three measurements in quick succession and calculates an average for a more reliable result. This mode is recommended for optimal accuracy.

  1. Ensure the MAM switch (if present on your model) is set to the 'ON' or 'MAM' position. If no switch is present, the device may automatically operate in MAM mode.
  2. Bonyeza kwa ANZA/ACHA kitufe. Kofi itaongezeka kiatomati.
  3. Remain still and silent during the entire measurement process. The device will take three consecutive measurements with short pauses in between.
  4. After the third measurement, the average blood pressure (systolic and diastolic) and pulse rate will be displayed.

6.4. AFIB Detection

During the measurement, the device continuously screens for Atrial Fibrillation. If AF is detected, a specific AFIB symbol (e.g., a heart with irregular waves) will appear on the display after the measurement results. If this symbol appears repeatedly, consult your physician for further evaluation.

7. Matengenezo na Matunzo

  • Kusafisha: Clean the monitor unit and cuff with a soft, dry cloth. Do not use abrasive cleaners, alcohol, or immerse the device in water.
  • Hifadhi: Store the device in its transport bag in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity.
  • Betri: Remove batteries if the device will not be used for an extended period to prevent leakage. Replace all four batteries simultaneously when the low battery indicator appears.
  • Utunzaji wa Cuff: The cuff is reusable but not washable. Avoid bending the air tube excessively.

8. Utatuzi wa shida

TatizoSababu inayowezekanaSuluhisho
Kifaa hakiwashiBetri zimeisha au kuingizwa vibaya.Check battery polarity; replace all four batteries.
Cuff does not inflate or inflates weaklyCuff connection is loose; air leakage; cuff damaged.Ensure cuff tube is securely connected; check cuff for damage.
Usomaji usio sahihi au usio sawaIncorrect cuff placement; movement or talking during measurement; improper resting before measurement.Review cuff placement instructions; remain still and silent; rest for 5 minutes before measuring.
AFIB symbol appears frequentlyPossible detection of Atrial Fibrillation.Consult your physician for medical advice and further examination.

9. Vipimo

  • Mfano: 70265
  • Mbinu ya Kipimo: Oscillometri
  • Masafa ya Kipimo:
    • Shinikizo: 20-280 mmHg
    • Pulse: 30-200 beats / dakika
  • Ukubwa wa Cuff: Conical pre-formed, 22-42 cm (M-L)
  • Vipimo: Takriban 160 x 80 x 32 mm
  • Uzito: Takriban 298 g (pamoja na betri)
  • Chanzo cha Nguvu: Betri za AAA 4 x 1.5V (zimejumuishwa)
  • Clinical Validation: ISO, EHS, BHS protocols, suitable for special patient groups (diabetics, elderly, obese, hypotensive, pregnant).
  • Vipengele Maalum: AFIB Technology for Atrial Fibrillation detection, MAM Technology for automatic triple measurement.

10. Udhamini na Msaada

For detailed warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official Microlife webtovuti. Weka risiti yako ya ununuzi kama uthibitisho wa ununuzi.

Mtengenezaji: COLPHARMA SRL

Nyaraka Zinazohusiana - 70265

Kablaview Microlife BP A200 AFIB: Ugunduzi Sahihi wa Shinikizo la Damu na AFIB
Gundua Microlife BP A200 AFIB, kifuatiliaji cha shinikizo la damu cha kidijitali cha kisasa kilichoundwa kwa ajili ya ufuatiliaji sahihi wa afya ya nyumbani. Kinapima kwa usahihi shinikizo la damu la sistoli na diastoli, pamoja na mapigo ya moyo, na kina teknolojia ya hali ya juu ya kugundua Mgandamizo wa Atrial (AFIB).
Kablaview Microlife BP A200 AFIB Blood Pressure Monitor User Manual
Comprehensive user manual for the Microlife BP A200 AFIB blood pressure monitor, detailing features, usage instructions, AFIB detection, and health monitoring.
Kablaview Microlife BP A200 AFIB: User Guide and Essential Information
Learn how to use the Microlife BP A200 AFIB blood pressure monitor for accurate readings and atrial fibrillation detection. Includes user instructions, safety information, and technical specifications.
Kablaview Microlife BP B3 AFIB Automatic Blood Pressure Monitor User Manual and Guide
Comprehensive user manual for the Microlife BP B3 AFIB automatic blood pressure monitor, covering preparation, measurement, AFIB detection, data memory, error handling, safety, and technical specifications.
Kablaview Mwongozo wa Mtumiaji wa Microlife BP B3 AFIB Kifuatilia Shinikizo la Damu
Comprehensive user manual for the Microlife BP B3 AFIB Blood Pressure Monitor, detailing setup, usage, AFIB detection, safety precautions, and technical specifications for accurate home blood pressure monitoring.
Kablaview Microlife BP A200 AFib Blood Pressure Monitor User Manual and Guide
Comprehensive user manual for the Microlife BP A200 AFib digital blood pressure monitor. Learn about accurate home blood pressure measurement, AFib detection, device operation, safety, and maintenance.