The Myers HJ50D is a convertible deep water well jet pump designed for reliable water supply from deep well applications. This 1/2 HP pump operates on either 115V or 230V, providing versatility for various electrical setups. It is engineered for efficient performance in residential and light commercial water systems.

Myers HJ50D Convertible Deep Water Well Jet Pump

An image showing the Myers HJ50D Convertible Deep Water Well Jet Pump, a green-colored unit with a motor on one end and the pump housing with inlet/outlet ports on the other. This pump is designed for deep well applications.

2. Taarifa za Usalama

Read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions can result in serious injury, death, or property damage.

3. Kuweka na Kuweka

3.1 Hundi za Kusakinisha Kabla

3.2 Kuweka Pampu

Mount the pump on a firm, level foundation to minimize vibration. Use appropriate bolts and washers to secure the pump base. Ensure the pump is as close to the well as practical to reduce suction lift.

3.3 Viunganisho vya mabomba

  1. Connect the suction line from the well to the pump's suction port. Ensure all connections are airtight to prevent air leaks.
  2. Connect the discharge line from the pump to the pressure tank and distribution system.
  3. Install a check valve in the suction line if not already present in the jet assembly.
  4. Install a pressure gauge and pressure switch on the discharge side.

3.4 Wiring za Umeme

Wire the pump according to the wiring diagram provided on the motor nameplate and local electrical codes. Ensure the correct voltage selection (115V or 230V) is made before connecting power. The pump must be properly grounded.

3.5 Kuchapisha pampu

Before initial startup, the pump casing and suction line must be completely filled with water. Remove the priming plug, slowly fill the pump with water until it overflows, then replace the plug securely. This process removes air from the pump, allowing it to create suction.

4. Maagizo ya Uendeshaji

4.1 Mwanzo wa kuanza

  1. Ensure the pump is properly primed as described in Section 3.5.
  2. Open a faucet in the system to allow air to escape.
  3. Restore power to the pump. The pump should start and begin to draw water.
  4. Once a steady stream of water flows from the faucet, close the faucet. The pump will build pressure and shut off when the pressure switch setting is reached.

4.2 Operesheni ya Kawaida

The pump will automatically cycle on and off based on the pressure switch settings, maintaining system pressure as water is used. Monitor the pressure gauge periodically to ensure proper operation.

4.3 Kuzima Bomba

To temporarily or permanently shut down the pump, disconnect the electrical power supply at the circuit breaker or fuse box. If shutting down for an extended period or for winterization, refer to the maintenance section.

5. Matengenezo

Regular maintenance ensures the longevity and efficient operation of your Myers HJ50D pump. Always disconnect power before performing any maintenance.

5.1 Ukaguzi wa Mara kwa Mara

5.2 Majira ya baridi

In areas subject to freezing temperatures, the pump and associated piping must be drained to prevent damage. Disconnect power, open drain plugs on the pump and any exposed piping, and allow all water to drain completely. Store the pump in a warm, dry place if possible, or ensure it is thoroughly drained and protected from freezing.

6. Utatuzi wa shida

This section provides solutions to common operational issues. For problems not listed or if solutions do not resolve the issue, contact a qualified service technician.

TatizoSababu inayowezekanaSuluhisho
Pampu haianza.No power; tripped circuit breaker; faulty pressure switch; motor issue.Check power supply; reset breaker; inspect/replace pressure switch; consult technician.
Pump runs but delivers no water.Pump not primed; air leak in suction line; low water level in well; clogged foot valve.Re-prime pump; check suction line connections; verify well water level; inspect/clean foot valve.
Shinikizo la chini la maji.Partially clogged lines; worn pump components; pressure switch setting too low; air in system.Inspect/clean lines; service pump; adjust pressure switch; bleed air from system.
Pampu inaendesha mfululizo.Leak in system; faulty pressure switch; pump unable to build pressure.Check for leaks; inspect/replace pressure switch; troubleshoot for no water/low pressure issues.

7. Vipimo

SifaMaelezo
ChapaMyers
Nambari ya MfanoHJ50D
Nambari ya SehemuHR50D
Nguvu ya Farasi (HP)1 / 2 HP
Voltage115V/230V
Chanzo cha NguvuAC/DC
Uzito wa KipengeePauni 44
MtindoConvertible Deep Water Well Jet Pump
UPC713356111732

8. Udhamini na Msaada

For detailed warranty information, please refer to the warranty card included with your product or visit the official Myers webtovuti. Weka risiti yako ya ununuzi kama dhibitisho la ununuzi kwa madai ya udhamini.

For technical support, replacement parts, or service inquiries, please contact Myers customer service. Contact details can typically be found on the manufacturer's webtovuti au katika ufungaji wa bidhaa.

Nyaraka Zinazohusiana - HJ50D

Kablaview Mwongozo wa Usakinishaji na Huduma za Mifumo ya Maji ya Myers HCM & HC Ejecto
Mwongozo kamili wa usakinishaji na huduma kwa Myers HCM na HC Ejecto Water Systems, unaotoa maelekezo ya kina, miongozo ya utatuzi wa matatizo, na taarifa za matengenezo ya pampu za visima vifupi na virefu.
Kablaview Myers MCR-220V/500W ZB+RF Smart Curtain Switch Mwongozo wa Mtumiaji
Mwongozo wa mtumiaji wa Myers MCR-220V/500W ZB+RF Smart Curtain Switch, unaoeleza kwa kina usakinishaji, usanidi, udhibiti na mipangilio kupitia programu ya simu ya Partizan na ZigBee Hub.
Kablaview Pampu ya Sump ya Ndani ya Myers S25: Maelekezo, Mwongozo wa Huduma, na Orodha ya Vipuri
Maagizo kamili, mwongozo wa huduma, na orodha ya vipuri kwa mfululizo wa Myers S25 Domestic Sump Pump, unaohusu usakinishaji, uendeshaji, matengenezo, na utatuzi wa matatizo. Inajumuisha maelezo ya modeli, uainishaji wa vipuri, na mwongozo wa utatuzi wa matatizo.
Kablaview Mfululizo wa Mfumo wa Illuminator wa MYERS Hypernova: 5-50 kVA/kW Mwongozo wa Watumiaji wa UPS
Mwongozo wa mtumiaji na kiufundi juuview for the MYERS Illuminator System Series Hypernova, a range of 5 kVA/kW to 50 kVA/kW emergency power systems (UPS). Includes installation, operation, safety, maintenance, and troubleshooting guidance.
Kablaview Myers SPS-4 Thermoplastic Submersible Utility Pump | Data Sheet
Explore the features and specifications of the Myers SPS-4 Thermoplastic Submersible Utility Pump. Ideal for light-duty drainage in basements, pools, and more, offering high performance and durability.