uxcell 1838

uxcell 1838 Infrared Remote Control Receiver Module Instruction Manual

Model: 1838 | Brand: uxcell

1. Utangulizi

The uxcell 1838 Infrared Remote Control Receiver Module is a miniaturized component designed for receiving infrared signals. It facilitates infrared remote control functionality and infrared data transmission in various electronic applications. This module is suitable for integration into a wide range of devices, including AV equipment and home appliances.

2. Bidhaa za Bidhaa

  • Jina la Bidhaa: Infrared Remote Control Receiver Module
  • Nambari ya Mfano: 1838
  • Ugavi Voltage: 2.7V hadi 5.5V DC
  • Umbali wa Mapokezi: 15 hadi mita 18
  • Muundo Kompakt: Miniaturized for space-saving integration
  • Programu pana: Compatible with AV equipment (MD audio, TV, VCR, CD, DVD) and home appliances (air conditioners, fans)
  • Nyenzo: Constructed from durable plastic and alloy components
  • Maudhui ya Kifurushi: Includes 2 units of the Infrared Remote Control Receiver Module

3. Vipimo

VipimoThamani
Jina la BidhaaInfrared Remote Control Receiver Module
Nambari ya Mfano1838
Ugavi Voltage2.7V - 5.5V
Umbali wa Mapokezi15 - 18 mita
Body Size (L x W x H)0.7 x 0.7 x 0.5 mm
Urefu wa siri22 mm
Pin Lami2.54 mm
NyenzoPlastic, Alloy
Weight (per module)2g
Teknolojia ya UunganishoInfrared
Vifaa SambambaTV (Universal)
Nambari ya Mfano wa Bidhaa (Mtengenezaji)a12052800ux0240
ASINB00AFVIX7Q
Vipimo vya Kifurushi14.22 x 9.65 x 0.25 cm
Uzito wa Bidhaa (Kifurushi)Gramu 99.79 (Pauni 0.22)

4. Kuweka na Kuweka

This module is designed for integration into custom electronic circuits. Installation typically involves soldering the module's pins to a circuit board.

4.1 Utambulisho wa Pin

  • VCC: Power supply input (2.7V - 5.5V)
  • GND: Uunganisho wa ardhi
  • NJE: Infrared signal output

4.2 Connection Guidelines

  1. Hakikisha ugavi wa umeme ujazotage iko ndani ya safu maalum ya 2.7V hadi 5.5V.
  2. Connect the VCC pin to the positive terminal of your power supply.
  3. Connect the GND pin to the ground of your circuit.
  4. Connect the OUT pin to the input of your microcontroller or signal processing circuit.
  5. Carefully solder the pins to avoid short circuits or damage to the module.
Two uxcell 1838 Infrared Remote Control Receiver Modules

Image 1: Two uxcell 1838 Infrared Remote Control Receiver Modules. These modules feature a compact, rectangular metal casing with a dark, translucent dome on top for infrared reception and three metal pins extending from the bottom for electrical connections.

5. Maagizo ya Uendeshaji

Once properly connected and powered, the uxcell 1838 module will continuously scan for incoming infrared signals. When an infrared signal, such as from a remote control, is detected within its reception range (15-18 meters), the module will output a corresponding electrical signal on its OUT pin.

  • The output signal typically requires decoding by a microcontroller or dedicated IR decoder IC to interpret the commands sent by the remote control.
  • Ensure a clear line of sight between the infrared remote control and the module for optimal performance.
Two uxcell 1838 Infrared Remote Control Receiver Modules with a size comparison inset

Image 2: This image displays two uxcell 1838 Infrared Remote Control Receiver Modules, similar to Image 1. Additionally, it includes a small inset picture showing a module being held between two fingers, illustrating its compact size and scale for practical applications.

6. Matengenezo

The uxcell 1838 Infrared Remote Control Receiver Module requires minimal maintenance. Adhere to the following guidelines to ensure longevity and reliable operation:

  • Weka Safi: Periodically clean the translucent dome of the module with a soft, dry cloth to prevent dust or debris from obstructing infrared reception.
  • Epuka unyevu: Protect the module from moisture and liquids, as this can cause electrical damage.
  • Udhibiti wa Halijoto: Operate and store the module within standard environmental temperatures. Avoid extreme heat or cold.
  • Kushughulikia kwa Uangalifu: Avoid applying excessive force to the pins or the module body during installation or handling.

7. Utatuzi wa shida

If you encounter issues with the Infrared Remote Control Receiver Module, consider the following troubleshooting steps:

  • Hakuna Mapokezi ya Mawimbi:
    • Verify that the module is correctly wired (VCC, GND, OUT).
    • Angalia ujazo wa usambazaji wa nguvutage to ensure it is within the 2.7V-5.5V range.
    • Ensure the remote control is functioning correctly (e.g., check battery).
    • Confirm there are no obstructions between the remote and the module.
  • Short Reception Range:
    • Ensure the module's dome is clean and free from dust or smudges.
    • Minimize sources of infrared interference (e.g., direct sunlight, strong incandescent lights).
    • Verify the remote control's infrared emitter is clean and functional.
  • Tabia Isiyo ya Kawaida:
    • Check for loose connections or poor solder joints.
    • Hakikisha usambazaji wa umeme ni thabiti na hauna kelele.
    • Review your signal decoding logic if using a microcontroller.

8. Udhamini na Msaada

Specific warranty information for the uxcell 1838 Infrared Remote Control Receiver Module is not provided in this manual. For details regarding warranty coverage, technical support, or replacement parts, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Nyaraka Zinazohusiana - 1838

Kablaview Ufungaji na Mwongozo wa Mmiliki wa Kidhibiti cha Ufikiaji cha Milango Mingi cha DoorKing 1838 PC kinachoweza kupangwa
Usakinishaji kamili na mwongozo wa mmiliki wa Kidhibiti cha Ufikiaji cha Milango Mingi Kinachoweza Kupangwa cha PC ya DoorKing 1838. Hushughulikia usanidi, nyaya, programu, vipimo, na utatuzi wa matatizo kwa udhibiti wa hali ya juu wa ufikiaji.
Kablaview Ufungaji wa Kinanda na Mwongozo wa Utayarishaji wa DoorKing Wiegand | Mifano 1815-051, 1815-052, 1815-059
DoorKing Wiegand Keypad Installation and Programming Guide. Learn how to install and program DoorKing digital keypads (models 1815-051, 1815-052, 1815-059, 1838-120, 1504-120). This guide covers essential wiring, master code setup, facility code configuration, and entry code boundary management for secure access control systems.
Kablaview Mwongozo wa Marejeleo ya Bidhaa za DoorKing: Mifumo ya Kudhibiti Ufikiaji kwa Simu, Video na Video
Mwongozo kamili wa marejeleo ya bidhaa kwa ajili ya mifumo mbalimbali ya DoorKing ya kuingiza simu, kuingiza video, na udhibiti wa ufikiaji, ikiwa ni pamoja na modeli 1802, 1808, 1810, 1812, 1816, 1819, 1833, 1834, 1835, 1837, 1838, 2108, 2112, 2132, na 2137. Vipengele vya maelezo, chaguo za muunganisho, vifaa, na vipimo.
Kablaview Lenovo ThinkPad Tablet with Android 4.0 User Guide
This comprehensive user guide provides detailed instructions for the Lenovo ThinkPad Tablet running Android 4.0. Learn about setup, features, wireless connectivity, app usage, security, troubleshooting, and more.
Kablaview DoorKing 1830-185 TCP/IP to RS-232 Converter Kit Instructions
Instructions for setting up and configuring the DoorKing 1830-185 TCP/IP to RS-232 Converter Kit for use with 1830 Series Telephone Entry and Access Control Systems.
Kablaview Bedienungsanleitung FISCHER Rettungszeichenleuchte SK mit Einzelbatterietechnik
Umfassende Bedienungsanleitung für die FISCHER Rettungszeichenleuchte SK mit Einzelbatterietechnik. Enthält Informationen zu Wartung, Prüfung, Montage, Inbetriebnahme und technischen Daten gemäß DIN EN Normen.