Airflow iCON ECO 15

Mwongozo wa Mtumiaji wa Fani ya Kiondoaji cha Aikoni ya Mtiririko wa Hewa ECO 15

Model: iCON ECO 15 | Brand: Airflow

1. Utangulizi

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Airflow iCon ECO 15 Extractor Fan. Please read these instructions thoroughly before installation and retain them for future reference. The Airflow iCon ECO 15 is a stylish, compact, low-profile fan designed for discreet ventilation in various domestic applications.

2. Taarifa za Usalama

Maagizo Muhimu ya Usalama:

  • Ensure the power supply is disconnected before installation, maintenance, or servicing.
  • Installation must be carried out by a qualified electrician in accordance with national wiring regulations and local building codes.
  • Kifaa hiki hakikusudiwa kutumiwa na watu (pamoja na watoto) walio na uwezo mdogo wa kimwili, hisi au kiakili, au wasio na uzoefu na ujuzi, isipokuwa wamepewa usimamizi au maagizo kuhusu matumizi ya kifaa na mtu anayehusika na usalama wao.
  • Watoto wanapaswa kusimamiwa ili kuhakikisha kwamba hawachezi na kifaa.
  • Do not install the fan directly above a shower or bath unless it is protected by a suitable enclosure.
  • Ensure that the air intake and exhaust vents are not obstructed.
  • The fan must not be connected to a chimney flue or any other appliance flue.

3. Bidhaa Imeishaview

The Airflow iCon ECO 15 is a 100mm (4-inch) axial extractor fan featuring an intelligent iris shutter design for efficient and quiet operation. Its low-profile aesthetic integrates seamlessly into modern interiors.

3.1 Sifa Muhimu

  • Iris Shutter Technology: Intelligent, award-winning design with a delayed shutter that opens and closes over up to 2 minutes. This avoids unnecessary operation for energy efficiency and prevents unwanted backdraughts.
  • Pro ya chinifile Muundo: Discreet and aesthetically pleasing.
  • Utofauti wa Moduli: Compatible with various control modules (sold separately) for enhanced functionality.
  • Operesheni ya utulivu: Designed for low noise levels.
Airflow iCon ECO 15 Extractor Fan, front view with closed iris shutter
Mbele view of the Airflow iCon ECO 15 Extractor Fan with its iris shutter closed, showing a smooth, unobtrusive appearance.
Airflow iCon ECO 15 Extractor Fan, front view with partially open iris shutter
Mbele view of the Airflow iCon ECO 15 Extractor Fan with the iris shutter partially open, revealing the internal grille.
Airflow iCon ECO 15 Extractor Fan, front view with fully open iris shutter
Mbele view of the Airflow iCon ECO 15 Extractor Fan with the iris shutter fully open, showing maximum airflow capacity.
Diagram illustrating iCON Iris Shutter Technology features
This image details the iCON Iris Shutter Technology, highlighting its intelligent design, delayed opening/closing for energy efficiency, and automatic closure to prevent backdraughts. Three fan states (closed, partially open, fully open) are shown.

4. Vipimo

Technical Data for Airflow iCon ECO 15
VipimoThamani
ChapaMtiririko wa hewa
Nambari ya MfanoiCON ECO 15
Aina ya shabikiAxial
Air Flow (m³/h / l/s)69 / 19
Nafasi ya KuwekaUkuta / Dari
Sound Pressure @ 3m (dB(A))28.8
Nguvu (W)9.4
Duct Diameter (mm)100
Ugavi Voltage230 V / 1ph / 50 Hz
Ukadiriaji wa Ulinzi wa IngressIPX4
Halijoto ya Juu ya Mazingira (°C)40
Uzito (kg)0.74
Vipimo H x W x D (mm)197 x 197 x 108.5
Technical data table for Airflow iCon 15
Detailed technical specifications for the iCon 15 fan, including airflow, power, noise level, and dimensions.
Dimensions diagram and static pressure performance graph for Airflow iCon 15
This image provides a dimensional drawing of the iCon 15 fan with key measurements (A, B, C, D, E) and a static pressure vs. airflow performance graph.
Energy label for Airflow iCon 15
The energy label for the Airflow iCon 15, indicating a 'C' energy efficiency rating, 29 dB noise level, and 68 m³/h airflow.

5. Ufungaji

The Airflow iCon ECO 15 fan is designed for installation in walls or ceilings. Always ensure the power supply is isolated before commencing any installation work.

5.1 Miongozo ya Jumla ya Ufungaji

  • The fan requires a 110mm diameter hole for installation.
  • For wall installations, the hole should be lined with a 100mm internal diameter duct.
  • When using flexible ducting, ensure the diameter is maintained throughout the run.
  • Ensure all vapor barriers are properly restored after installation.

5.2 Wall Installation (Recessing Fan)

The iCon 15 requires a 110mm diameter hole through the wall. This hole should be lined with a 100mm internal diameter duct.

5.3 Ceiling Installation (Recess)

The fan should be fitted in the hole, secured with the screws provided into the support structure. The iCon 15 requires a 110mm diameter hole through the ceiling.

5.4 Ceiling Installation (Surface Mounting)

When surface mounting, the fan is fitted into the mounting skirt (if supplied). The iCon 15 requires a 110mm diameter hole through the ceiling. When recessing or surface mounting in the ceiling, a plywood support (min. 18mm thick) must be mounted between the ceiling joists. Any fixing screws should be fitted through the plasterboard into this support.

Installation diagrams for wall and ceiling mounting of iCon fans
This image displays various installation methods: wall recessing, ceiling recessing, and ceiling surface mounting, with diagrams illustrating ducting and support requirements for iCon 15, 30, and 60 models.
Upande view of Airflow iCon ECO 15 with ducting
Pro wa upandefile of the Airflow iCon ECO 15 fan, showing the integrated duct connection for ventilation systems.

6. Maagizo ya Uendeshaji

The Airflow iCon ECO 15 operates automatically based on its intelligent iris shutter technology. When activated (e.g., by a light switch or an optional control module), the iris shutter will slowly open, and the fan will begin to extract air. Upon deactivation, the fan will continue to run for a set period (if a timer module is installed) before the shutter slowly closes, preventing backdraughts.

6.1 Control Modules (Sold Separately)

The iCon ECO 15 is designed to be upgraded with various 'snap-in' interchangeable control modules to suit specific ventilation needs. These modules offer functionalities such as:

  • Basic Switching: Simple on/off operation.
  • Kuchelewa Kuanza: Fan starts after a delay.
  • Sensor ya unyevu: Activates based on room humidity levels.
  • Kitambuzi cha Mwendo: Activates upon detecting movement.
  • Pullcord: Manual activation via a pull cord.
  • Room Refresh: Periodic ventilation.
  • SELV: Usalama Ziada Chini Voltage.
  • Kipima muda: Fan runs for a set duration after activation.
  • Two Speed: Allows selection between two fan speeds.
  • Kasi inayobadilika: Kasi ya shabiki inayoweza kubadilishwa.

Refer to the specific control module's instructions for detailed operating procedures.

Diagram showing various smart control modules for Airflow iCon fans
This image illustrates the modular design of the iCon fan, showing how different 'snap-in' control modules (e.g., Basic, Delay Start, Humidity, Motion Sensor, Timer) can be added to upgrade its functionality. An exploded view of the fan's internal components is also visible.

7. Matengenezo

Regular cleaning and maintenance will ensure the longevity and optimal performance of your Airflow iCon ECO 15 Extractor Fan.

  • Ondoa Nguvu: Always ensure the power supply to the fan is disconnected before performing any maintenance.
  • Kusafisha kifuniko: The front cover can be gently wiped with a damp kitambaa na sabuni kali. Epuka cleaners abrasive.
  • Kusafisha Vile vya Fani: Carefully remove the front cover (refer to installation instructions for removal). Gently clean the fan blades and internal surfaces with a soft brush or damp kitambaa. Hakikisha unyevu hauingii kwenye vipengele vya umeme.
  • Kukusanya upya: Once clean and dry, reassemble the fan cover, ensuring it is securely fitted.
  • Mara kwa mara: Cleaning should be performed periodically, depending on the environment and usage, typically every 3-6 months.

8. Utatuzi wa shida

If you experience issues with your Airflow iCon ECO 15 fan, consult the following common troubleshooting steps:

TatizoSababu inayowezekanaSuluhisho
Shabiki haifanyi kazi.No power supply; faulty wiring; fan motor failure; control module issue.Check power supply at the switch and fuse box. Verify wiring connections (by a qualified electrician). If using a control module, check its functionality.
Shabiki ana kelele.Obstruction in ducting or fan blades; loose mounting; worn bearings.Disconnect power and inspect fan blades and ducting for obstructions. Ensure the fan is securely mounted. If noise persists, professional inspection may be required.
Poor extraction performance.Blocked ducting; dirty fan blades; incorrect fan size for room.Clean fan blades and check ducting for blockages. Ensure ducting is correctly installed and not excessively long or restrictive.
Iris shutter not opening/closing.Obstruction; motor fault; control module issue.Disconnect power and check for any physical obstructions around the shutter mechanism. If using a control module, verify its operation.

For issues not listed here or if solutions do not resolve the problem, please contact Airflow customer support or a qualified technician.

9. Taarifa za Udhamini

Airflow Developments Ltd guarantees the iCon fan for miaka 3 from the date of purchase against faulty material or workmanship. This warranty is applicable to units installed and used in the United Kingdom.

You can register your warranty online for more information at www.airflow.com.

The warranty covers only the fan and does not include reinstallation if required. In the event of any defective parts being found, Airflow Developments Ltd reserves the right to repair or replace the unit at their discretion without charge, provided that:

  1. It has been installed and used in accordance with the fitting and wiring instructions supplied with each unit.
  2. It has not been connected to an unsuitable electrical supply.
  3. It has not been subjected to misuse, neglect, or damage.
  4. It has not been modified or repaired by any person not authorized by Airflow Developments Ltd.
  5. It has been installed in accordance with the latest Building Regulations and IET wiring regulations by a person who is recognized as a competent installer (e.g., NICEIC Ventilation Scheme).

Airflow Developments Ltd shall not be liable for any loss, injury, or other consequential damage arising from a failure of the equipment, except only that nothing in this condition shall be construed as to exclude or restrict liability for negligence.

This warranty does not affect any statutory or other consumer rights.

For detailed standard warranty terms and conditions, please visit the Airflow webtovuti au wasiliana na Huduma kwa Wateja.

Airflow product warranty information and contact details
This image provides the warranty statement from Airflow Developments Ltd, outlining the 3-year guarantee, conditions for validity, and limitations of liability. It also includes disposal information and contact details for various regions.

10. Msaada na Mawasiliano

For further assistance, frequently asked questions (FAQs), and installation help, please visit the Airflow Knowledge Base:

airflow.com/useful-links/knowledge-base-faqs

Airflow iCON Extractor Fan FAQs and knowledge base link
This image directs users to the Airflow website's Knowledge Base for FAQs and installation support related to iCON Extractor Fans.

Nyaraka Zinazohusiana - iCON ECO 15

Kablaview Mtiririko wa hewa wa iCON 230V wa Mashabiki: Mwongozo wa Usakinishaji na Uendeshaji
Mwongozo wa kina wa usakinishaji na uendeshaji wa safu ya feni za Airflow iCON 230V, unaoeleza kinaganaga usakinishaji wa kielektroniki na kimitambo, moduli za hiari, urekebishaji na maelezo ya udhamini.
Kablaview Mtiririko wa Hewa wa Aura-eco Fan Range: Mwongozo wa Usakinishaji na Uendeshaji
Mwongozo kamili wa usakinishaji na uendeshaji wa aina mbalimbali za feni za 230V za Airflow Aura-eco (modeli 100, 125, 150). Hushughulikia usakinishaji wa umeme na mitambo, vipengele vya feni, marekebisho, matengenezo, udhamini, na utupaji.
Kablaview Kifaa cha Vipuri vya ICON 15/30 cha mtiririko wa hewa chenye Kiashirio - Mwongozo wa Maelekezo
Mwongozo wa kina wa maelekezo ya kusakinisha vifaa vya ziada vya Airflow iCON 15/30, ikijumuisha kiendeshaji, klipu, chemchemi, na skrubu. Jifunze jinsi ya kubadilisha vipuri vya feni yako ya iCON.
Kablaview Airflow iCON 30S Shabiki wa Uingizaji hewa: Uingizaji hewa maridadi katika Bafu
Gundua Airflow iCON 30S, feni maridadi na bora ya 12V DC ya vyumba vya kulala, bafu na vyumba vya matumizi. Inaangazia Tuzo la Usanifu la Reddot lililoshinda shutter ya iris kimya, matumizi ya chini ya nishati, na chaguo nyingi za moduli za udhibiti.
Kablaview Aikoni ya mtiririko wa hewa ya SELV 12V Fan Range: Mwongozo wa Usakinishaji na Uendeshaji
Mwongozo kamili wa usakinishaji na uendeshaji wa aina mbalimbali za feni za Airflow iCON SELV 12V DC, zinazofunika vipimo, usakinishaji wa umeme na mitambo, matengenezo, na udhamini. Vipengele Usalama wa Ziada ya Chini Voliyumutage (SELV) fans suitable for domestic premises.
Kablaview Mtiririko wa Hewa Aura-eco 100mm na 150mm Axial Feni: Maelekezo ya Usakinishaji na Uendeshaji
This document provides comprehensive installation, operating, and maintenance instructions for the Airflow Aura-eco 100mm and 150mm axial fans. It includes safety guidelines, technical specifications, connection diagrams, sensor adjustments, and warranty information.