Fluke TL175

Mwongozo wa Mtumiaji wa Fluke TL175 TwistGuard Test Leads

Mfano: TL175

1. Utangulizi

The Fluke TL175 TwistGuard Test Leads are designed for electrical measurement applications, offering enhanced safety and versatility. These test leads feature an adjustable tip shroud mechanism and a WearGuard lead wire wear indication system, ensuring reliable performance and user safety across various measurement environments. They are compatible with all instruments that accept standard 4mm shrouded banana plugs.

2. Taarifa za Usalama

WARNING: To prevent possible electrical shock, fire, or personal injury:

  • Always use the test leads with the appropriate safety category rating for the measurement environment.
  • Inspect test leads for damage before each use. Do not use if insulation is damaged or if the inner contrasting color of the WearGuard system is exposed.
  • Ensure the test lead tips are fully inserted into the measurement device.
  • Usitumie zaidi ya juzuu iliyokadiriwatage, as marked on the test leads.
  • Keep fingers behind the finger guards on the probes during measurements.
  • Tumia tahadhari wakati wa kufanya kazi na voltagzaidi ya 30 V AC RMS, kilele cha 42 V, au 60 V DC. Voliyumu hizitaginaleta hatari ya mshtuko.

3. Bidhaa za Bidhaa

  • TwistGuard Extendable Tip Shroud: Patented design allows users to twist the probe handle to extend or retract the tip shroud, reducing tip exposure for higher safety categories (CAT III, CAT IV) and providing full tip exposure for lower categories (CAT II).
  • WearGuard Lead Wire Indication: Each test lead features two layers of silicone insulation. If the outer layer is nicked or scuffed, the inner contrasting color becomes visible, indicating the need for replacement.
  • Double Insulated Silicone Leads: Designed to withstand high temperatures and maintain flexibility in cold conditions.
  • Extra-Heavy Duty Strain Relief: Reinforced strain relief on both probe-end and plug-end for enhanced durability, tested beyond 30,000 bends.
  • Universal Input Plugs: Compatible with all instruments that accept standard 4mm shrouded banana plugs.
  • Removable 4mm Lantern Tips: Includes removable tips that thread onto the lead tip for versatile connections.
Fluke TL175 TwistGuard Test Leads

Kielelezo 1: Zaidiview of Fluke TL175 TwistGuard Test Leads, showing the red and black leads with their respective probe tips and banana plugs.

4. Kuweka na Kuweka

  1. Inspect Leads: Before connecting, visually inspect both test leads for any signs of damage, cuts, or exposed inner insulation. If damage is found, replace the leads immediately.
  2. Unganisha kwenye Kifaa: Insert the shrouded banana plugs (black for common, red for voltage/current) firmly into the corresponding input jacks of your multimeter or test instrument. Ensure a secure connection.
    Fluke TL175 Test Leads connected to a multimeter

    Figure 2: Fluke TL175 Test Leads properly connected to a digital multimeter.

  3. Adjust TwistGuard Shroud: The TwistGuard feature allows you to adjust the exposed tip length.
    • For CAT II measurements (e.g., wall outlets), twist the probe handle to fully expose the 19mm tip.
    • For CAT III or CAT IV measurements (e.g., circuit breaker panels, main service), twist the probe handle to retract the shroud, exposing only the 4mm tip for increased safety.
      Hand demonstrating the TwistGuard feature on a Fluke TL175 test lead

      Figure 3: A hand twisting the probe handle to adjust the TwistGuard tip shroud.

  4. Attach Lantern Tips (Optional): If your application requires a different connection type, the included 4mm lantern tips can be threaded onto the probe tips.

5. Maagizo ya Uendeshaji

Once properly connected and adjusted, the Fluke TL175 Test Leads function as standard test probes for your electrical measurements. Always refer to your multimeter's instruction manual for specific measurement procedures.

  • Voltage Kipimo: Chagua juzuu inayofaatage range on your multimeter. Ensure the TwistGuard shroud is set for the correct safety category. Place the black probe on the common or ground point and the red probe on the point to be measured.
  • Kipimo cha Sasa: For current measurements, ensure the red lead is connected to the correct current input jack on your multimeter (e.g., 10A or mA). The circuit must be broken to insert the meter in series.
  • Resistance/Continuity: Select the resistance or continuity function. The leads can be used to test circuit continuity or component resistance.
Fluke TL175 Test Lead being used to measure in a circuit breaker panel

Figure 4: Using a Fluke TL175 Test Lead in a circuit breaker panel, demonstrating a CAT IV application with the shroud retracted.

Fluke TL175 Test Leads being used to test an electrical outlet

Figure 5: Fluke TL175 Test Leads used to test an electrical outlet, suitable for CAT II applications with tips fully exposed.

6. Matengenezo

  • Kusafisha: Clean the test leads with a damp kitambaa na sabuni kali. Usitumie visafishaji vya abrasive au vimumunyisho.
  • Ukaguzi: Regularly inspect the leads for any signs of wear or damage, especially the WearGuard insulation. If the inner contrasting color is exposed, the leads are compromised and should be replaced to maintain safety.
  • Hifadhi: Store the test leads in a clean, dry environment, away from extreme temperatures and direct sunlight. Avoid sharp bends or kinks in the cables.

7. Utatuzi wa shida

  • No Reading or Intermittent Reading:
    • Ensure the banana plugs are fully inserted into the multimeter.
    • Check for visible damage to the lead insulation or connectors.
    • Perform a continuity test on the leads themselves by touching the tips together. If no continuity, the leads may be internally broken and require replacement.
  • Usomaji usio sahihi:
    • Verify the multimeter is set to the correct function and range.
    • Ensure the test lead tips are making good contact with the circuit points.
    • Check for corrosion or dirt on the probe tips or banana plugs.

8. Vipimo

KipengeleVipimo
Nambari ya MfanoTL175
Ukadiriaji wa UsalamaCAT II 1000V, CAT III 1000V, CAT IV 600V, 10A maximum, Pollution Degree 2
Exposed Probe Tip Length19mm to 4mm (0.75" to 0.16") adjustable
Nyenzo ya Waya ya RisasiDouble Insulated Silicone
Joto la Uendeshaji-20 hadi 55 °C (-4 hadi 131 °F)
Mwinuko2000m (6,562')
KuzingatiaEN61010-031
Vipimo vya BidhaaInchi 10 x 3 x 2
Uzito wa KipengeeGramu 120 (wakia 4.23)

Ni nini kwenye Sanduku:

  • Fluke TL175 TwistGuard Test Leads (Red and Black)
  • Removable 4mm Lantern Tips

9. Udhamini na Msaada

The Fluke TL175 TwistGuard Test Leads come with a 1-year warranty from the date of purchase, covering defects in materials and workmanship. For warranty claims, technical assistance, or further information, please contact Fluke Corporation customer support or visit the official Fluke webtovuti.

Mtengenezaji: Shirika la Fluke

Tarehe ya Kwanza Inapatikana: Juni 1, 2011

Nyaraka Zinazohusiana - TL175

Kablaview Fluke 179 Digital Multimeter: Matengenezo na Mwongozo wa Huduma ya Uga
Gundua Multimeter ya Fluke 179 True-rms Digital, iliyoundwa kwa ajili ya matengenezo bora ya umeme na HVAC. Jifunze kuhusu vipengele vyake, vipimo, na vifaa vinavyopendekezwa kwa ajili ya huduma ya shambani inayotegemeka.
Kablaview Mwongozo wa Mtumiaji wa Fluke 15B+/17B+/18B+ Multimita za Kidijitali
Comprehensive user manual for Fluke 15B+, 17B+, and 18B+ digital multimeters, covering features, operation, safety, maintenance, and specifications. This document provides detailed instructions for using the multimeters for various electrical measurements.
Kablaview Vipimo vya Dijitali vya Fluke 106/107 vya Palmsized: Vipimo vya Kiufundi na Sifa
Vipimo vya kina vya kiufundi, vivutio vya bidhaa, na taarifa ya jumla ya mita za kidijitali za Fluke 106 na 107 zenye mikono. Jifunze kuhusu vipimo vyao vya umeme, usahihi, vipengele, na vifaa vilivyojumuishwa.
Kablaview Kipima-sauti cha Dijitali cha Fluke 107 cha Mkononi cha CAT III - Vipimo vya Kiufundi
Vipimo vya kina vya kiufundi, vipengele, na taarifa za jumla za multimita ya kidijitali ya Fluke 107 inayoweza kushikiliwa kwa mkono ya CAT III. Inajumuisha vipimo vya umeme, ukadiriaji wa usalama, na maelezo ya kuagiza.
Kablaview Kifaa cha Adapta cha Fluke FEV100 cha Vituo vya Kuchaji vya Magari ya Umeme: Data ya Kiufundi na Maelezo.
Gundua ubainifu wa kiufundi, vipengele na taratibu za majaribio za Kifaa cha Adapta cha Fluke FEV100, kilichoundwa ili kujaribu kwa usalama na kwa ufanisi vituo vya kuchaji magari ya umeme (EVSEs). Inajumuisha maelezo ya usalama, uoanifu na maelezo ya kuagiza.
Kablaview Multimeter ya Fluke 110 True-RMS: Maelezo ya Kiufundi na Vipengele
Ufafanuzi wa kina na vipengele vya multimeter ya Fluke 110 compact True-RMS, iliyoundwa kwa ajili ya ufungaji sahihi wa umeme na utatuzi wa matatizo. Inajumuisha usahihi, ukadiriaji wa usalama na vifuasi vilivyojumuishwa.