Utangulizi
The Extech DL150 is a True RMS AC voltage and current data logger designed for precise measurement and recording of electrical parameters. It is capable of logging up to 100,000 readings of TRMS AC Voltage (up to 600V) or Current (up to 200 Amp). This device features a user-programmable sample rate ranging from 1 second to 24 hours, providing flexibility for various monitoring needs. The integrated LCD displays real-time data including time/date, current readings, and minimum/maximum values. It also indicates if user-settable high/low alarms have been exceeded. Data can be easily downloaded to a PC via the USB interface for analysis using the included software or for export to a spreadsheet. The DL150 supports Normal, Peak, and Capture (user-specified trigger level) recording modes, making it a versatile tool for electrical diagnostics and monitoring.
Ni nini kwenye Sanduku

Image: The Extech DL150 Datalogger shown with all its included accessories, neatly laid out. This includes the main unit, current clamp, test leads, alligator clips, software CD, USB cable, 110-Volt AC Adapter, and a 3.6V Lithium Battery.
Baada ya kufungua kifurushi, tafadhali hakikisha kwamba vipengele vyote vifuatavyo vipo:
- Extech DL150 True RMS AC Voltage/Current Datalogger Unit
- Cl ya sasaamp
- Miongozo ya Mtihani
- Sehemu za Alligator
- Software (on CD or available for download)
- Kebo ya USB
- Adapta ya AC ya 110-Volt
- Betri ya Lithium ya 3.6V
If any items are missing or damaged, please contact Extech customer support immediately.
Sanidi
1. Ufungaji wa Betri
The DL150 requires 4 AAA batteries (included). To install, locate the battery compartment on the rear of the unit. Open the compartment cover, insert the batteries observing the correct polarity (+/-), and then securely close the cover. Ensure the battery is properly seated for continuous operation.
2. Ufungaji wa Programu
Before connecting the datalogger to your computer, install the provided software. Insert the software CD into your computer's drive and follow the on-screen instructions. If a CD drive is not available, the software can typically be downloaded from the official Extech website. This software is essential for configuring the datalogger, downloading recorded data, and analyzing measurements.
3. Connecting the Datalogger
Connect the DL150 to your computer using the supplied USB cable. The USB port is located on the side of the datalogger. Once connected, the computer should recognize the device, and you can launch the Extech software to begin configuration.
4. Attaching Test Leads and Current Clamp
Kwa voltage measurements, connect the test leads to the appropriate input jacks on the DL150. For current measurements, connect the current clamp to its designated input. Ensure all connections are secure before proceeding with any measurements.
Uendeshaji

Image: The Extech DL150 Datalogger showing its LCD screen with a clear voltage reading and time/date information. The device's buttons for power, Min/Max, Start/Stop, and Peak are visible.
1. Kuwasha/Kuzima
Bonyeza kwa Nguvu button to turn the DL150 on or off. The LCD will illuminate, displaying the current time and date, along with measurement readings.
2. Configuring Datalogging Parameters
Use the Extech software on your PC to configure the datalogging parameters. This includes setting the sample rate (from 1 second to 24 hours), selecting the measurement type (AC Voltage or AC Current), and defining high/low alarm thresholds. You can also choose between Normal, Peak, and Capture recording modes.
3. Starting and Stopping Data Logging
Once configured, press the ANZA/ACHA button on the device to begin data logging. The LCD will indicate that logging is active. Press the same button again to stop logging. The device can store up to 100,000 readings.
4. Viewing Min/Max and Peak Readings
During or after logging, press the MAX/MIN button to cycle through the minimum and maximum recorded values. Press the KILELE kifungo kwa view the peak reading captured during the logging session.
5. Downloading Data
Connect the DL150 to your PC via the USB cable. Open the Extech software and follow the instructions to download the logged data. The software allows you to view the data graphically, export it to various formats (e.g., CSV for spreadsheets), and generate reports.
Matengenezo
1. Kusafisha Kitengo
Wipe the exterior of the DL150 with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is dry before storage or further use.
2. Kubadilisha Betri
When the battery indicator on the LCD shows low power, replace the 4 AAA batteries promptly to ensure accurate readings and continuous operation. Refer to the "Battery Installation" section under Setup for detailed steps.
3. Hifadhi
When not in use for extended periods, store the DL150 in a cool, dry place, away from direct sunlight and extreme temperatures. It is recommended to remove the batteries if storing for more than one month to prevent leakage.
Kutatua matatizo
This section provides solutions to common issues you might encounter with your Extech DL150.
- Kifaa hakiwashi:
- Angalia kama betri zimewekwa kwa usahihi na polarity sahihi.
- Badilisha betri na mpya.
- Hakikisha kitufe cha kuwasha/kuzima kimebonyezwa kwa uthabiti.
- Hakuna kumbukumbu ya data:
- Verify that the START/STOP button was pressed to initiate logging.
- Check if the memory is full (the device can log up to 100,000 readings). Download data to clear memory.
- Hakikisha sample rate is correctly configured in the software.
- Cannot connect to PC / Software issues:
- Ensure the USB cable is securely connected to both the DL150 and the PC.
- Verify that the Extech software drivers are correctly installed. You may need to reinstall the software or download the latest drivers from the Extech webtovuti.
- Jaribu mlango tofauti wa USB kwenye kompyuta yako.
- Usomaji usio sahihi:
- Ensure test leads and current clamp are properly connected and making good contact with the circuit.
- Verify that the correct measurement type (AC Voltage or AC Current) is selected.
- Angalia kiwango cha betri; betri za chini zinaweza kuathiri usahihi.
For more detailed troubleshooting or issues not covered here, please refer to the full user manual PDF or contact Extech customer support.
Vipimo
| Kipengele | Vipimo |
|---|---|
| Nambari ya Mfano | DL150 |
| Aina ya Kipimo | Kweli RMS AC Voltage / Ya sasa |
| Voltage Mbalimbali | Hadi 600V AC |
| Masafa ya Sasa | Hadi 200A AC |
| Datalogging Capacity | Usomaji 100,000 |
| Sample Kiwango | Programmable from 1 second to 24 hours |
| Onyesho | LCD with time/date, current reading, Min/Max, alarm indicators |
| Kiolesura | USB |
| Njia za Kurekodi | Normal, Peak, Capture (user-specified trigger level) |
| Chanzo cha Nguvu | Inaendeshwa na Betri (betri 4 za AAA zimejumuishwa) |
| Vipimo vya Bidhaa | Inchi 2.5 x 1.3 x 4.5 |
| Uzito wa Kipengee | Wakia 8.82 (Kilo 0.25) |
| Mtengenezaji | Extech |
Udhamini na Msaada
Extech products are designed for reliability and performance. For detailed warranty information, including terms, conditions, and duration, please refer to the official user manual PDF provided with your product or available for download from the Extech webtovuti. Dhamana kwa kawaida hushughulikia kasoro katika vifaa na ufundi chini ya matumizi ya kawaida.
For technical support, service, or to purchase accessories, please visit the official Extech webtovuti au wasiliana na idara yao ya huduma kwa wateja. Unaweza kupata taarifa za mawasiliano na rasilimali za ziada kwenye Extech Brand Store on Amazon or directly through the Extech corporate webtovuti.
Nyenzo za ziada: