Leviton 24W49

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug

Model 24W49 Instruction Manual

1. Bidhaa Imeishaview

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is a robust wiring device designed for demanding industrial environments. This plug features a polarized, grounding, L6-15P configuration with 3 wires, rated for 250V AC and 15 Amps. It is constructed from EPTR rubber material in a yellow color, ensuring water-tight performance and resistance to various harsh conditions. The Wetguard line meets IP67 and NEMA ratings for water ingress protection, offering superior durability and reliability.

Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug, Model 24W49

Figure 1: Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49)

2. Sifa Muhimu

  • Industrial Grade Construction: Imejengwa kuhimili mazingira magumu ya viwanda.
  • Watertight and Dust-tight: Meets IP67 and NEMA ratings for protection against water and dust ingress.
  • Nyenzo Zinazodumu: Made from EPTR rubber, resistant to water, acids, alkalis, lubricants, cleaners, and solvents.
  • Upinzani wa kutu: Blades, contacts, terminal screws, and wiring clamps are electroless nickel-coated brass.
  • Wiring Rahisi: Deep wire wells in the wiring module facilitate easier wiring.
  • Ukaguzi wa Visual: Clear housing aids in inspecting for proper wire insertion and connection.
  • Muunganisho Salama: Patented compression nut and strain relief system ensure integrity of both the watertight seal and electrical connection.
  • Usanidi: L6-15P, 2-pole, 3-wire grounding.
  • Vyeti: UL 498, CSA C22.2, NOM 057 approved.

3. Vipimo

VipimoThamani
Nambari ya Mfano24W49
Ampkizazi15 Amps
Voltage250 Volts
Fomati ya JaladaType A (L6-15P)
Idadi ya Waya3
Idadi ya Poles2
KutulizaNdiyo
NyenzoEPTR Rubber
RangiNjano
Cord Size Compatibility0.234 hadi 0.687 inchi
Vipimo vya BidhaaInchi 1.44 x 1.3 x 3.54
Uzito wa Kipengee3.2 wakia
VyetiUL 498, CSA C22.2, NOM 057

4. Taarifa za Usalama

Always follow local electrical codes and regulations when installing or servicing electrical devices. Improper installation or use can result in serious injury or death. Disconnect power at the circuit breaker or fuse box before working on any electrical wiring.

  • Ensure the power supply is OFF before installation or maintenance.
  • Use appropriate personal protective equipment (PPE) such as safety glasses and insulated gloves.
  • Verify correct wiring polarity and grounding connections.
  • Usizidi ujazo uliotajwatage na amperage ratings of the device.
  • Keep the device clean and free from debris to maintain its watertight integrity.
  • If the device shows signs of damage, discontinue use and replace it immediately.

5. Ufungaji

This section outlines the general steps for wiring the Leviton Wetguard Locking Plug. For detailed wiring diagrams and specific instructions, refer to the packaging or consult a qualified electrician.

  1. Tayarisha Cable: Strip the outer jacket of the cable to the appropriate length, exposing the insulated conductors. Strip the insulation from each conductor.
  2. Tenganisha Plug: Unscrew the compression nut and separate the plug housing components.
  3. Weka Kebo: Feed the prepared cable through the compression nut and into the plug housing.
  4. Viunganisho vya Waya: Connect the conductors to the appropriate terminal screws. The clear housing allows for visual verification of proper wire insertion. Ensure all connections are tight and secure.
  5. Assemble the Plug: Reassemble the plug housing, ensuring the internal components are correctly aligned. Tighten the compression nut to create a watertight seal and engage the strain relief system.
  6. Thibitisha: Double-check all connections and ensure the plug is securely assembled before restoring power.

6. Uendeshaji

The Leviton Wetguard Locking Plug is designed for secure and reliable electrical connections in wet or dusty environments. To operate:

  1. Unganisha: Align the blades of the locking plug with the corresponding slots on a compatible locking receptacle.
  2. Pindua hadi Kufunga: Insert the plug fully and twist it clockwise until it locks into place. This action creates a secure mechanical and electrical connection, preventing accidental disconnection.
  3. Tenganisha: To disconnect, twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.

The watertight design ensures safe operation even when exposed to moisture, provided the connection is properly mated and sealed.

7. Matengenezo

Regular maintenance helps ensure the longevity and safe operation of your Leviton Wetguard Locking Plug.

  • Ukaguzi wa Mara kwa Mara: Visually inspect the plug and cable for any signs of wear, cuts, cracks, or discoloration. Check for loose connections or corrosion on the blades.
  • Kusafisha: Clean the exterior of the plug with a damp cloth. Avoid using harsh chemicals or abrasive cleaners that could damage the rubber material. Ensure the plug is dry before use.
  • Hifadhi: When not in use, store the plug in a clean, dry environment to prevent damage and prolong its lifespan.
  • Tiba Uadilifu: Periodically check the integrity of the compression nut and strain relief system to ensure the watertight seal is maintained.

8. Utatuzi wa shida

If you encounter issues with your Leviton Wetguard Locking Plug, consider the following common troubleshooting steps:

  • Hakuna Nguvu:
    • Check the power source (circuit breaker, fuse).
    • Ensure the plug is fully inserted and locked into the receptacle.
    • Kagua kebo kwa uharibifu.
  • Muunganisho Huru:
    • Ensure the plug is twisted and locked securely.
    • If the internal wiring feels loose, disconnect power and re-check the terminal screw connections as per installation instructions.
  • Kuingia kwa Maji:
    • Verify that the compression nut is tightly secured.
    • Inspect the rubber housing for any cracks or damage that could compromise the seal.

If the problem persists after attempting these steps, contact Leviton customer support or a qualified electrician.

9. Related Product Information (Video)

The following video provides an overview of the Leviton Wetguard line of watertight wiring devices, showcasing their features and applications in various industrial environments. While the video may feature different models within the Wetguard series, the core principles of durability, watertight sealing, and robust construction apply to the 24W49 locking plug.

Video: Imekwishaview of Leviton Wetguard Watertight Wiring Devices

10. Udhamini na Msaada

The Leviton Wetguard 15-Amp, 250-Volt Industrial Grade Locking Plug (Model 24W49) is backed by a manufacturer's warranty. For specific warranty details, terms, and conditions, please refer to the product packaging or visit the official Leviton webtovuti.

For technical assistance, product inquiries, or support, please contact Leviton Customer Service:

  • Webtovuti: www.leviton.com
  • Huduma kwa Wateja: Rejea webtovuti kwa maelezo ya mawasiliano ya kikanda.

Nyaraka Zinazohusiana - 24W49

Kablaview Mwongozo wa Uteuzi wa Swichi za Daraja la Leviton Commercial & Industrial
Mwongozo wa kina wa uteuzi kutoka kwa Leviton unaoelezea swichi za daraja la kibiashara na kiviwanda, ikijumuisha kugeuza, Decora Plus, Lev-lok, antimicrobial, na aina za swichi maalum zenye maelezo ya programu na michoro ya nyaya.
Kablaview Mwongozo wa Ufungaji na Upimaji wa Kipokezi cha Leviton GFCI
Mwongozo kamili wa jinsi ya kusakinisha na kujaribu Kipokezi cha Leviton SmartLock Pro GFCI, ikijumuisha maagizo ya waya, tahadhari za usalama, na vidokezo vya utatuzi wa matatizo.
Kablaview Mfululizo wa 40 wa Leviton EV40P EV AMP Mwongozo wa Usakinishaji wa Chaja ya Programu-jalizi
Mwongozo wa usakinishaji wa Leviton EV40P EV Series 40 AMP Chaja ya Gari ya Umeme Iliyounganishwa. Inajumuisha maonyo ya usalama, vipimo, hatua za usakinishaji, taratibu za uendeshaji, matumizi ya kadi ya RFID, ujumbe wa makosa, matengenezo, na taarifa za udhamini.
Kablaview Leviton GFCI Outlet yenye Usakinishaji wa Bandari za USB na Mwongozo wa Uendeshaji
Mwongozo wa kina wa kusakinisha na kufanya kazi Vifaa vya Leviton GFCI vilivyo na Bandari za USB, ikijumuisha maagizo ya nyaya, maonyo ya usalama, taratibu za majaribio na maelezo ya udhamini.
Kablaview Kusakinisha na Kujaribu Leviton Smart GFCI Outlet: Mwongozo Kamili
Maagizo ya hatua kwa hatua ya kusakinisha na kujaribu soketi za Leviton Smart GFCI (modeli D2GF1, D2GF2). Jifunze kuhusu utendaji wa GFCI, nyaya za umeme, utatuzi wa matatizo, na tahadhari za usalama.
Kablaview Leviton Load Center Enclosure Installation Instructions
Detailed installation instructions for Leviton Load Center Enclosures, models LP2xx, LP3xx, LP4xx, and LP6xx. Covers safety, knockout removal, mounting, wiring, branch circuit breaker installation, and cover fitting.