Utangulizi
The Intermatic PE153P is a versatile 3-circuit digital timer designed for automatic control of electrical loads. This 24-hour control mechanism allows for precise scheduling of various applications, including lighting, heating, air conditioning, and pool or spa pumps. Each circuit can manage loads up to 17 amps. This manual provides essential information for the safe installation, programming, operation, and maintenance of your PE153P digital timer.

Kielelezo cha 1: Intermatic PE153P 3-Circuit Digital Timer. This image shows the timer unit with its rainproof enclosure open, revealing the digital display, control buttons, and wiring terminals. The enclosure is designed to protect the internal components from environmental elements.
Taarifa za Usalama
Daima zingatia tahadhari zifuatazo za usalama ili kupunguza hatari ya moto, mshtuko wa umeme au majeraha:
- Installation must be performed by a qualified electrician and in accordance with all national and local electrical codes.
- Disconnect power at the circuit breaker or fuse box before installing or servicing the timer.
- Hakikisha kipima muda kimetulia vizuri.
- Do not exceed the maximum load ratings for each circuit (17 amps).
- This device is intended for outdoor use and is housed in a rainproof enclosure. Ensure the enclosure is securely closed after installation and servicing.
Ufungaji na Usanidi
Kuweka Enclosure
- Select a suitable location for mounting the timer. The location should be easily accessible for programming and maintenance, and protected from direct sunlight if possible to prolong LCD life.
- Use appropriate mounting hardware (not included) to secure the enclosure to a flat, vertical surface. Ensure the enclosure is level.
Maagizo ya Wiring
ONYO: Disconnect power at the main service panel before wiring. Failure to do so may result in serious injury or death.
- Open the timer enclosure.
- Identify the input terminals (LINE 1, LINE 2, NEUTRAL) and output terminals for each of the three circuits (LOAD 1, LOAD 2, LOAD 3).
- Connect the incoming power supply wires to the appropriate input terminals. For 120V operation, connect LINE 1 and NEUTRAL. For 240V operation, connect LINE 1 and LINE 2.
- Connect the load wires for each device you wish to control to the corresponding output terminals.
- Ensure all wire connections are tight and secure. Use copper conductors only, rated for at least 75°C.
- Funga na ufunge mlango wa uzio.
Maagizo ya Uendeshaji
Kuanzisha Upyaji wa Awali na Mpangilio wa Muda
- Restore power to the timer at the main service panel.
- The LCD display will illuminate. If the display is blank, check power connections.
- Bonyeza kwa PROGRAM kitufe cha kuingiza modi ya upangaji.
- Tumia UP na CHINI arrows to set the current time (hour and minute).
- Bonyeza INGIA ili kudhibitisha kila mpangilio.
- Set the current day of the week using the UP na CHINI arrows, then press INGIA.
Ratiba za Kuandaa
The PE153P offers seven preprogrammed modes and custom programming. Refer to the detailed programming section in the full manual for advanced settings.
- Bonyeza PROGRAM repeatedly to cycle through the available circuits (CIRCUIT 1, CIRCUIT 2, CIRCUIT 3).
- Once the desired circuit is selected, press INGIA to begin setting ON/OFF times.
- Tumia UP na CHINI arrows to set the ON time, then press INGIA.
- Repeat for the OFF time.
- Select the days of the week for this schedule to be active.
- Bonyeza PROGRAM to save and exit, or to move to the next program event.
Batilisha kwa Mwongozo
To manually turn a circuit ON or OFF outside of its programmed schedule, press the corresponding BATILISHA button for that circuit. The override will remain active until the next programmed event or until manually cancelled.
Matengenezo
The Intermatic PE153P digital timer requires minimal maintenance. Periodically inspect the enclosure for any signs of damage or wear. Ensure the door seal is intact to maintain its rainproof rating. Keep the display and buttons clean and free of debris. No user-serviceable parts are inside the sealed unit beyond the wiring terminals.
Kutatua matatizo
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| Onyesho ni tupu. | Hakuna nguvu kwa kitengo. | Check circuit breaker/fuse. Verify wiring connections. |
| Load does not turn ON/OFF as programmed. | Incorrect programming; Manual override active; Faulty wiring; Load exceeding capacity. | Review programming schedule. Check for active manual override. Inspect wiring. Ensure load is within 17A per circuit. |
| Muda sio sahihi. | Time not set correctly; Power interruption. | Reset current time and day. The internal battery should maintain time during short power outages. |
If troubleshooting steps do not resolve the issue, contact Intermatic customer support.
Vipimo
| Mfano | PE153P |
| Chapa | Intermatic |
| Uingizaji Voltage | 120/240 VAC, 60 Hz |
| Idadi ya Mizunguko | 3 independent circuits |
| Mzigo wa Juu kwa kila Mzunguko | 17 Amps (resistive/inductive), 1000W tungsten, 3 HP |
| Aina ya Uzio | Rainproof (Type 3R) |
| Sifa Muhimu | LCD Readout, Multivoltage Input/Output, Countdown, Override, Freeze Protection, Heater Protection |
| Uzito wa Kipengee | Pauni 2.55 |
Udhamini na Msaada
Taarifa ya Udhamini
Intermatic products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or visit the official Intermatic webtovuti. Weka uthibitisho wako wa ununuzi kwa madai ya udhamini.
Usaidizi wa Wateja
For technical assistance, programming questions, or to report a problem, please contact Intermatic customer support. Visit the Duka la Intermatic kwenye Amazon au afisa wao webtovuti kwa maelezo ya mawasiliano na rasilimali za ziada.