1. Bidhaa Imeishaview
This manual provides essential information for the safe and effective use of the Apollo Valve 13-213 Series Bronze Safety Relief Valve. This valve is designed for protecting small to medium low-pressure steam heating boilers by removing excess pressure from the system.
Vipengele muhimu ni pamoja na:
- Relief pressure preset of 15 psi for releasing excess pressure.
- 1-1/4" male NPT threaded inlet for connecting to a female NPT threaded connection.
- Cast bronze body and steel spring for corrosion resistance.
- Flat seat, PTFE-faced disc for positive seal.
- ASME safety rated for Section IV heating boilers.

Kielelezo 1: Mbele view of the Apollo Valve 13-213 Series Bronze Safety Relief Valve, showing the bronze body, NPT connections, and the pressure relief lever.
2. Taarifa za Usalama
Always adhere to local codes and regulations when installing and operating pressure relief devices. Improper installation or maintenance can lead to serious injury or property damage.
- Ensure the system is depressurized and cooled before attempting any installation, maintenance, or inspection.
- Vaa vifaa vinavyofaa vya kinga ya kibinafsi (PPE), pamoja na miwani ya usalama na glavu.
- Usifanye tamper with the factory-set pressure. Any alteration voids the warranty and can compromise safety.
- Ensure proper discharge piping is installed to safely vent steam away from personnel and equipment.
- Regularly inspect the valve for signs of wear, corrosion, or damage.
3. Components and Design
The Apollo Valve 13-213 Series is constructed with durable materials designed for steam applications. Key components include:
- Mwili: Cast bronze for corrosion resistance and durability.
- Kiti: Flat seat design with a PTFE-faced disc for a positive seal, resistance to moisture, and high temperatures. This design also facilitates positive drainage of condensate.
- Spring: Steel spring mechanism for reliable pressure relief.
- Viunganisho: 1-1/4" male NPT inlet and 1-1/2" female NPT outlet for secure pipe connections.

Kielelezo 2: Upande view of the Apollo Valve 13-213 Series, highlighting the inlet and outlet connections and the robust bronze construction.
4. Kuweka na Kuweka
Proper installation is critical for the safe and effective operation of the relief valve. Consult a qualified professional if you are unsure about any step.
- Maandalizi ya Mfumo: Ensure the steam boiler system is completely shut down, depressurized, and cooled before beginning installation.
- Uunganisho wa Inlet: Thread the 1-1/4" male NPT inlet of the relief valve into the corresponding female NPT connection on the boiler. Use appropriate thread sealant (e.g., PTFE tape or pipe dope) suitable for steam applications. Tighten securely to prevent leaks, but do not overtighten.
- Muunganisho wa Outlet: Connect the 1-1/2" female NPT outlet of the relief valve to a discharge pipe. This pipe must be adequately sized and routed to safely vent steam to an open atmosphere or a designated safe discharge area, away from personnel and equipment. Ensure the discharge pipe has no obstructions, traps, or valves that could impede flow.
- Mwelekeo: Install the valve in an upright position, ensuring the discharge path is clear and unobstructed.
- Angalia Uvujaji: After installation, slowly bring the system up to operating pressure and carefully check all connections for leaks. Address any leaks immediately.
5. Maagizo ya Uendeshaji
The Apollo 13-213 Series Safety Relief Valve operates automatically to protect the boiler from overpressure conditions. It is designed to open when the system pressure reaches its factory-set relief pressure of 15 psi.
- Uendeshaji Otomatiki: When the boiler pressure exceeds 15 psi, the valve will automatically open to discharge steam, reducing the pressure within the system.
- Reseating: Once the system pressure drops below the reseating pressure (typically slightly below the set pressure), the valve will automatically close, restoring the seal.
- Manual Test Lever: The valve is equipped with a manual test lever. It is recommended to periodically test the valve by lifting the lever to ensure it operates freely and discharges steam. This should be done carefully and only when the boiler is at a safe operating pressure, ensuring the discharge path is clear. Refer to boiler manufacturer guidelines for specific testing frequency.
6. Matengenezo
Regular maintenance ensures the longevity and reliable operation of your safety relief valve. Always ensure the system is depressurized and cooled before performing any maintenance.
- Ukaguzi wa Visual: Periodically inspect the valve for any signs of external damage, corrosion, or leaks. Check the discharge piping for obstructions.
- Jaribio la Mwongozo: As mentioned in the operating instructions, perform periodic manual tests using the lever to ensure the valve opens and closes freely.
- Kusafisha: Keep the exterior of the valve clean. Do not use harsh chemicals that could damage the bronze or other components.
- Ukaguzi wa Kitaalam: It is recommended to have the valve inspected and serviced by a qualified professional at regular intervals, as per industry standards or local regulations.
7. Utatuzi wa shida
This section addresses common issues you might encounter with your safety relief valve.
| Tatizo | Sababu inayowezekana | Suluhisho |
|---|---|---|
| Valve Leaks Continuously | Debris on seat, damaged seat/disc, incorrect system pressure. | Manually cycle the valve to clear debris. If leaking persists, the valve may need replacement or professional servicing. Verify system pressure is below set point. |
| Valve Does Not Open | System pressure not reaching set point, valve stuck due to corrosion/deposits, incorrect valve for application. | Verify boiler pressure gauge accuracy. Attempt manual test. If stuck, valve may need replacement. Ensure valve specifications match system requirements. |
| Valve Opens Prematurely | System pressure fluctuating, valve spring fatigue, incorrect valve for application. | Monitor system pressure stability. If valve is old or frequently cycles, it may need replacement. Ensure valve specifications match system requirements. |
For issues not listed or if solutions do not resolve the problem, contact a qualified technician or the manufacturer.
8. Vipimo
Detailed technical specifications for the Apollo Valve 13-213 Series Bronze Safety Relief Valve:
- Nambari ya Mfano: 13213B15
- Aina ya Valve: Valve ya Kupunguza Shinikizo
- Nyenzo: Bronze (Body), Steel (Spring), PTFE (Seat Disc)
- Weka Shinikizo: 15 psi (Pounds per Square Inch)
- Aina ya Muunganisho wa Ingizo: 1-1/4" NPT Male Threaded
- Aina ya Muunganisho wa Toleo: 1-1/2" FNPT Female Threaded
- Kiwango cha juu cha Kufanya kazi: Up to 250 degrees F
- Idadi ya Bandari: 2
- Uzingatiaji: ASME Section IV - Low Pressure Steam Heating Boilers
- Mtengenezaji: Conbraco
- Tarehe ya Kwanza Inapatikana: Mei 31, 2012
- Vipimo vya Kifurushi: Inchi 5.04 x 3.5 x 2.91
- Uzito wa Kipengee: Pauni 2.05
9. Taarifa za Udhamini
Specific warranty details for the Apollo Valve 13-213 Series are not provided within this manual. For comprehensive warranty information, please refer to the official documentation provided with your purchase or contact Apollo Valves directly through their official webtovuti au njia za huduma kwa wateja.
10. Msaada na Mawasiliano
If you require technical assistance, have questions regarding installation, operation, or maintenance, or need to report an issue, please contact the manufacturer:
- Chapa: APOLLO
- Mtengenezaji: Conbraco
- Webtovuti: www.apollovalves.com (Please note: This is a general link to the brand's website, specific support pages may vary.)
Always provide your product model number (13213B15) when seeking support.