APOLLO 13213B15

Apollo Valve 13-213 Series Bronze Safety Relief Valve User Manual

Mfano: 13213B15

1. Bidhaa Imeishaview

This manual provides essential information for the safe and effective use of the Apollo Valve 13-213 Series Bronze Safety Relief Valve. This valve is designed for protecting small to medium low-pressure steam heating boilers by removing excess pressure from the system.

Vipengele muhimu ni pamoja na:

Apollo Valve 13-213 Series Bronze Safety Relief Valve, front view

Kielelezo 1: Mbele view of the Apollo Valve 13-213 Series Bronze Safety Relief Valve, showing the bronze body, NPT connections, and the pressure relief lever.

2. Taarifa za Usalama

Always adhere to local codes and regulations when installing and operating pressure relief devices. Improper installation or maintenance can lead to serious injury or property damage.

3. Components and Design

The Apollo Valve 13-213 Series is constructed with durable materials designed for steam applications. Key components include:

Apollo Valve 13-213 Series Bronze Safety Relief Valve, side view

Kielelezo 2: Upande view of the Apollo Valve 13-213 Series, highlighting the inlet and outlet connections and the robust bronze construction.

4. Kuweka na Kuweka

Proper installation is critical for the safe and effective operation of the relief valve. Consult a qualified professional if you are unsure about any step.

  1. Maandalizi ya Mfumo: Ensure the steam boiler system is completely shut down, depressurized, and cooled before beginning installation.
  2. Uunganisho wa Inlet: Thread the 1-1/4" male NPT inlet of the relief valve into the corresponding female NPT connection on the boiler. Use appropriate thread sealant (e.g., PTFE tape or pipe dope) suitable for steam applications. Tighten securely to prevent leaks, but do not overtighten.
  3. Muunganisho wa Outlet: Connect the 1-1/2" female NPT outlet of the relief valve to a discharge pipe. This pipe must be adequately sized and routed to safely vent steam to an open atmosphere or a designated safe discharge area, away from personnel and equipment. Ensure the discharge pipe has no obstructions, traps, or valves that could impede flow.
  4. Mwelekeo: Install the valve in an upright position, ensuring the discharge path is clear and unobstructed.
  5. Angalia Uvujaji: After installation, slowly bring the system up to operating pressure and carefully check all connections for leaks. Address any leaks immediately.

5. Maagizo ya Uendeshaji

The Apollo 13-213 Series Safety Relief Valve operates automatically to protect the boiler from overpressure conditions. It is designed to open when the system pressure reaches its factory-set relief pressure of 15 psi.

6. Matengenezo

Regular maintenance ensures the longevity and reliable operation of your safety relief valve. Always ensure the system is depressurized and cooled before performing any maintenance.

7. Utatuzi wa shida

This section addresses common issues you might encounter with your safety relief valve.

TatizoSababu inayowezekanaSuluhisho
Valve Leaks ContinuouslyDebris on seat, damaged seat/disc, incorrect system pressure.Manually cycle the valve to clear debris. If leaking persists, the valve may need replacement or professional servicing. Verify system pressure is below set point.
Valve Does Not OpenSystem pressure not reaching set point, valve stuck due to corrosion/deposits, incorrect valve for application.Verify boiler pressure gauge accuracy. Attempt manual test. If stuck, valve may need replacement. Ensure valve specifications match system requirements.
Valve Opens PrematurelySystem pressure fluctuating, valve spring fatigue, incorrect valve for application.Monitor system pressure stability. If valve is old or frequently cycles, it may need replacement. Ensure valve specifications match system requirements.

For issues not listed or if solutions do not resolve the problem, contact a qualified technician or the manufacturer.

8. Vipimo

Detailed technical specifications for the Apollo Valve 13-213 Series Bronze Safety Relief Valve:

9. Taarifa za Udhamini

Specific warranty details for the Apollo Valve 13-213 Series are not provided within this manual. For comprehensive warranty information, please refer to the official documentation provided with your purchase or contact Apollo Valves directly through their official webtovuti au njia za huduma kwa wateja.

10. Msaada na Mawasiliano

If you require technical assistance, have questions regarding installation, operation, or maintenance, or need to report an issue, please contact the manufacturer:

Always provide your product model number (13213B15) when seeking support.

Nyaraka Zinazohusiana - 13213B15

Kablaview Mwongozo wa Mtumiaji wa Scooter ya Umeme ya Apollo - Mipangilio, Uendeshaji na Usalama
Mwongozo wa kina wa mtumiaji wa skuta ya umeme ya Apollo Air, usanidi wa kufunika, uendeshaji, miongozo ya usalama, matengenezo na maelezo ya udhamini. Jifunze jinsi ya kufurahia Apollo Air yako kwa usalama.
Kablaview Mwongozo wa Kusakinisha Sanduku la Kufulia la Sukuma Ili Kuunganisha
Karatasi ya maelekezo ya kusakinisha Kisanduku cha Kufulia cha Tectite na Apollo Push-To-Connect, ikijumuisha usakinishaji wa hatua kwa hatua na maelezo ya usanidi wa vali.
Kablaview Apollo Tank Max 69TANKMAX Installation Instructions
Detailed installation instructions and safety precautions for the Apollo Tank Max 69TANKMAX thermostatic mixing valve, designed to provide more hot water safely.
Kablaview Mwongozo wa Mtumiaji wa Scooter ya Umeme ya Apollo Go
Mwongozo wa kina wa mtumiaji wa skuta ya umeme ya Apollo Go, usanidi, uendeshaji, matengenezo, utatuzi na miongozo ya usalama.
Kablaview Mwongozo wa Mtumiaji wa Scooter ya Umeme ya Apollo Go
Mwongozo huu wa mtumiaji unatoa maagizo ya kina ya skuta ya umeme ya Apollo Go, inayohusu unboxing, kuunganisha, uendeshaji, kuchaji, matengenezo, miongozo ya usalama, utatuzi wa matatizo na maelezo ya udhamini. Pata maelezo kuhusu jinsi ya kusanidi, kuendesha na kutunza skuta yako ya umeme ya Apollo Go.
Kablaview Apollo 23G Electric Fireplace Insert Assembly and User Manual
Comprehensive guide for assembling and operating the Apollo 23G electric fireplace insert, including safety instructions, parts identification, and troubleshooting tips for model HF190108/OLLIEFIR.