Utangulizi
This manual provides detailed instructions for the installation, operation, and maintenance of your Intermatic EI210 Electronic in-Wall Countdown Timer. Please read these instructions carefully before installation and use to ensure proper functionality and safety.
Sifa Muhimu:
- Uendeshaji Rahisi: Easily select countdown times of 10, 20, 30, or 60 minutes with the push of a single button—no programming needed.
- Utangamano wa Universal: Replaces single-pole switches, compatible with a range of Intermatic products.
- Operesheni ya Kimya: Operates without mechanical noise.
- Ufungaji Rahisi: Straightforward setup.
- Pembe za Ndovu Maliza: Blends seamlessly with your decor.
Taarifa Muhimu za Usalama
WARNING: TO AVOID FIRE, SHOCK, OR DEATH, TURN OFF POWER AT CIRCUIT BREAKER AND TEST THAT POWER IS OFF BEFORE WIRING.
- Kifaa hiki kimekusudiwa kwa matumizi ya ndani tu.
- Hakikisha miunganisho yote ya waya ni salama.
- Wasiliana na fundi umeme aliyehitimu ikiwa huna uhakika kuhusu sehemu yoyote ya mchakato wa usakinishaji.
Maagizo ya Ufungaji
Follow these steps for proper installation of your EI210 timer:
- Zima Nguvu: Remove the wall plate and disconnect the existing light switch. Ensure power is OFF at the circuit breaker and verify with a tester before proceeding.
- Angalia Wiring: Confirm that both "hot" and neutral wires are present in the junction box. If neutral wires are not present, additional wiring may be required.
- Connect Timer Wires:
- Unganisha nyekundu timer wire to the wire leading to the fixture (load) using a wire connector.
- Unganisha nyeusi timer wire to the incoming "hot" (usually black or red) wire from the power source in the junction box using a wire connector.
- Kata nyeupe wire in the junction box (or open splice) and strip 3/8" of insulation. Connect the nyeupe timer wire to the white (neutral) wires in the junction box using a wire connector.
- If the wall switch you are replacing had separate grounding conductors connected to a GREEN screw, connect these to the kijani wire from the timer with a wire connector.
- Miunganisho Salama: Double-check that all wire connections are secure and properly insulated.
- Mount the Timer: Carefully place all wires inside the junction box. Fit the timer into the junction box and secure it using the two mounting screws provided.
- Rejesha Nguvu: Reconnect electrical power at the circuit breaker.

Figure 1: Wiring Diagram for Intermatic EI210. This diagram illustrates the connection of the timer's neutral (white) and hot (black or red) wires within a standard junction box.

Figure 2: Detailed Wiring Diagram. This diagram shows the connections for hot, ground, and white wires, ensuring proper electrical setup for the timer.
Maagizo ya Uendeshaji

Intermatic EI210 Timer Faceplate. This image displays the timer's front panel with buttons for 10, 20, 30, 60 minutes, and a HOLD function.
Njia ya Timer
To activate the timer mode, press and release the push button (for less than 2 seconds) repeatedly. Each press will cycle through the available countdown settings: 10, 20, 30, or 60 minutes. An illuminated LED next to the selected time indicates the current setting, and the connected load will turn ON. The timer will begin counting down, and once the selected time has elapsed, all 5 LEDs will turn off, and the connected load will turn OFF.
Hali ya Kushikilia (Operesheni Endelevu)
To keep the connected load ON for an indefinite period, press and hold the push button for more than 2 seconds. The timer will enter HOLD mode, indicated by the HOLD LED illuminating. The connected load will remain ON continuously. To exit HOLD mode, press and release the push button. All 5 LEDs will turn off, and the connected load will also turn OFF.
Matengenezo
The Intermatic EI210 timer is designed for maintenance-free operation. To clean the surface, use a soft, damp cloth. Avoid using abrasive cleaners or solvents, as these may damage the finish or internal components.
Kutatua matatizo
If your Intermatic EI210 timer is not functioning as expected, consider the following:
- Hakuna Nguvu: Ensure the circuit breaker supplying power to the timer is ON. Verify all wiring connections are secure as per the installation instructions.
- Load Not Turning On/Off: Check if the timer is in the correct mode (Timer Mode or Hold Mode). If in Timer Mode, ensure a countdown time is selected. If in Hold Mode, ensure the HOLD LED is illuminated.
- Uendeshaji usio thabiti: Re-verify wiring connections. Ensure the timer is not exposed to extreme temperatures or moisture.
If issues persist, contact Intermatic customer support for further assistance.
Vipimo
| Kipengele | Maelezo |
|---|---|
| Nambari ya Mfano | EI210 |
| Countdown Times | 10, 20, 30, 60 dakika |
| Uendeshaji | Electronic, Push Button |
| Maliza Rangi | Pembe za Ndovu |
| Wattage | 1800 watts |
| Aina ya Kuweka | Mlima wa Ukuta |
| Mtindo wa Kubadili | Geuza Swichi |
| Uthibitisho | UL (Canada and US) |
| Vipimo vya Bidhaa | Inchi 2.9 x 2.1 x 4.6 |
| Uzito wa Kipengee | 4.8 wakia |
| UPC | 078275095229 |
Taarifa ya Udhamini
This Intermatic product comes with a dhamana ya mwaka 1. This warranty covers replacement of the unit but does not include labor costs. For warranty claims or further details, please contact Intermatic customer support.
Usaidizi wa Wateja
For technical assistance, troubleshooting, or warranty inquiries, please visit the official Intermatic webtovuti au wasiliana na idara yao ya huduma kwa wateja. Maelezo ya mawasiliano yanaweza kupatikana kwenye kifungashio cha bidhaa au cha mtengenezaji webtovuti.
Bidhaa Imeishaview Video
Video: Intermatic In-Wall Timer Overview. Video hii inatoa maelezo ya jumlaview of Intermatic in-wall timers, including features and benefits. While it may not specifically feature the EI210 model, it demonstrates the general functionality and installation concepts common to the product line.