TOMZN TOQ7e

TOMZN TOQ7e WiFi Smart ATS Dual Power Switch Instruction Manual

1. Utangulizi

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your TOMZN TOQ7e WiFi Smart Automatic Transfer Switch (ATS). Please read this manual thoroughly before installation and keep it for future reference.

The TOMZN TOQ7e is designed to automatically switch between two power sources, typically city power (Source A) and a generator or secondary power source (Source B), ensuring a continuous power supply to your electrical load. It features WiFi connectivity for smart control and monitoring via the EWelink application.

2. Taarifa za Usalama

Improper installation or operation can lead to serious injury or damage to the device. Always adhere to the following safety guidelines:

  • Ufungaji wa Kitaalamu Unapendekezwa: Installation should only be performed by a qualified electrician in accordance with all local and national electrical codes.
  • Ondoa Nguvu: Always ensure that all power sources are disconnected before performing any installation, wiring, or maintenance.
  • Voltage na Ukadiriaji wa Sasa: Verify that the device's voltage and current ratings match your electrical system requirements.
  • Uwekaji Sahihi: Ensure the device is properly grounded to prevent electrical shock.
  • Masharti ya Mazingira: Usiweke kifaa kwenye unyevu mwingi, vumbi, au halijoto kali zaidi ya kiwango chake maalum cha uendeshaji.
  • Miunganisho Salama: Ensure all wire connections are tight and secure to prevent overheating and arcing.

3. Bidhaa Imeishaview

The TOMZN TOQ7e ATS is a compact and intelligent device designed for reliable power transfer. It integrates automatic switching capabilities with smart home features.

Mbele view of TOMZN TOQ7e ATS with controls and labels

Kielelezo 1: Mbele view of the TOMZN TOQ7e ATS, showing the manual/auto selector, indicator lights, and terminal connections.

Multiple TOMZN TOQ7e ATS units in various configurations

Figure 2: Multiple TOMZN TOQ7e ATS units, illustrating various pole configurations and current ratings.

Vipengele Muhimu:

  • Power Source A (City Power) Terminals: Connections for the primary power supply.
  • Power Source B (Generator) Terminals: Connections for the secondary power supply.
  • Vituo vya Kupakia: Output connections to the electrical load.
  • Manual/Auto Selector Switch: Allows selection between manual operation and automatic transfer mode.
  • Taa za Viashiria: Display the status of Source A, Source B, and the current power supply.
  • Moduli ya WiFi: Enables smart control and monitoring via the EWelink app.

4. Vipimo

KipengeleVipimo
MfanoTOQ7e
Iliyokadiriwa Sasa63A, 100A, 125A (variant dependent)
Imekadiriwa Voltage220V / 380V AC
Nguzo2P, 3P, 4P (variant dependent)
Aina ya KudhibitiAutomatic, Manual, WiFi (EWelink)
Vipengele vya UlinziShort Circuit, Overload
Nyenzo ya MakaziInsulating, Flame-retardant, UV-resistant
VituoAina ya screw
UthibitishoCE
Masafa ya Uendeshaji50/60 Hz
Vipimo (Takriban.)Refer to product packaging or specific model datasheet for precise measurements.

5. Ufungaji

Onyo: Ensure all power is disconnected before proceeding with installation. Installation must be performed by a qualified electrician.

5.1 Kuweka

The TOMZN TOQ7e ATS is designed for DIN rail mounting.

  1. Select a suitable location within your electrical panel or enclosure that provides adequate ventilation and protection from environmental factors.
  2. Attach the ATS securely to a standard DIN rail by engaging the mounting clip at the bottom of the device.
Chini view of TOMZN TOQ7e ATS showing DIN rail mounting clip

Kielelezo 3: Chini view of the TOMZN TOQ7e ATS, showing the DIN rail mounting clip for secure installation.

Wiring

Follow the wiring diagram provided with your specific product variant or consult a qualified electrician. The general wiring principle involves connecting Source A (City Power), Source B (Generator), and the Load to their respective terminals.

  • Source A (City Power): Connect the main utility power lines to the 'Source A' input terminals.
  • Source B (Generator/Secondary Power): Connect the generator or secondary power lines to the 'Source B' input terminals.
  • Pakia: Connect the electrical circuits or appliances you wish to power to the 'Load' output terminals.
  • Ensure correct phase and neutral connections.
  • Tighten all screw terminals firmly to prevent loose connections and potential hazards.

6. Maagizo ya Uendeshaji

6.1 Uendeshaji wa Mwongozo

The ATS can be manually switched between power sources using the selector switch on the front panel.

  1. Ensure the selector switch is in the 'Manual' position.
  2. Rotate the switch to select either 'Source A' or 'Source B' to supply power to the load.
  3. Observe the indicator lights to confirm the active power source.

6.2 Operesheni ya Moja kwa Moja

For automatic power transfer, set the selector switch to the 'Auto' position.

  • When 'Source A' (City Power) is available, the ATS will automatically connect the load to Source A.
  • If 'Source A' fails, the ATS will detect the outage and, after a pre-set delay, automatically switch the load to 'Source B' (Generator), provided Source B is available and stable.
  • When 'Source A' is restored, the ATS will automatically switch the load back to Source A after a pre-set delay.
  • Indicator lights will show the status of each source and which source is currently supplying power.

6.3 WiFi Connectivity and EWelink App

The TOMZN TOQ7e integrates with the EWelink app for remote monitoring and control.

  1. Download EWelink App: Download the EWelink app from your smartphone's app store (iOS or Android).
  2. Sajili/Ingia: Create an account or log in to your existing EWelink account.
  3. Ongeza Kifaa: Follow the in-app instructions to add a new device. This typically involves putting the ATS into pairing mode (refer to the device's specific pairing instructions, usually by pressing and holding a button) and connecting to your home WiFi network.
  4. Remote Control & Monitoring: Once connected, you can monitor the status of both power sources, view current power usage (if supported by the specific model), and remotely switch between manual and auto modes, or even trigger a manual transfer.
  5. Kazi za Kipima muda: Utilize the app's timer features to schedule power transfers or monitor events.

7. Matengenezo

Regular maintenance ensures the longevity and reliable operation of your ATS.

  • Ukaguzi wa Mara kwa Mara: Annually inspect the device for any signs of physical damage, loose connections, or discoloration.
  • Usafi: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Ugumu wa Kituo: Periodically check and re-tighten all screw terminals to ensure secure electrical connections.
  • Mtihani wa Utendaji: Periodically test the automatic transfer function by simulating a power outage (e.g., by temporarily disconnecting Source A, if safe to do so and with proper precautions).

8. Utatuzi wa shida

If you encounter issues with your TOMZN TOQ7e ATS, refer to the following troubleshooting guide:

TatizoSababu inayowezekanaSuluhisho
Device not switching automaticallySelector switch in 'Manual' position. One or both power sources unavailable/unstable.Set selector to 'Auto'. Check power supply to Source A and Source B. Ensure generator is running and stable.
No power output to loadNo active power source. Overload or short circuit tripped internal protection. Loose wiring.Verify both Source A and Source B are active. Check for tripped circuit breakers upstream. Inspect and tighten all wiring connections.
Matatizo ya muunganisho wa WiFiIncorrect WiFi password. Device too far from router. Router issues.Ensure correct WiFi password. Move device closer to router or use a WiFi extender. Restart router. Re-attempt pairing process.
Taa za viashiria hazifanyi kaziNo power to the device. Faulty unit.Check power supply. If power is present and lights are still off, contact support.

Ikiwa tatizo litaendelea baada ya kujaribu suluhisho hizi, wasiliana na huduma kwa wateja au fundi umeme aliyehitimu.

9. Udhamini na Msaada