SmartGen HAT560NB

SmartGen HAT560NB ATS Controller User Manual

1. Utangulizi

The SmartGen HAT560NB ATS Controller is an intelligent dual-supply module designed for Automatic Transfer Systems (ATS). It integrates digital, intelligent, and networked functionalities to provide precise voltage measurement and control for various power supply configurations. This controller is suitable for specialized ATS, Contactor ATS, and Air Break ATS applications, offering a compact structure, advanced circuitry, and high reliability.

It is engineered to reduce operational errors through automatic measurement and control, making it an ideal solution for managing power transfer between different sources like mains and generators.

SmartGen HAT560NB ATS Controller front view with LCD display and control buttons

Kielelezo 1: Mbele view of the SmartGen HAT560NB ATS Controller, showing the LCD display and operational buttons.

2. Features and Characteristics

The HAT560NB controller incorporates a powerful microprocessor for accurate monitoring and control. Key features include:

  • System type configuration: Mains (1#) & Generator (2#), Generator (1#) & Mains (2#), Mains (1#) & Mains (2#), Generator (1#) & Generator (2#).
  • 132x64 LCD with backlight, offering optional Chinese and English display with push-button operation.
  • Measurement and display of 2-way 3-phase voltage na frequency.
  • Ulinzi dhidi ya juu/chini ya juzuutage, loss of phase, reverse phase sequence, and over/under frequency.
  • Automatic and Manual operating modes. Manual mode allows forced switch closure or opening.
  • All parameters are configurable on-site, secured by two different passwords for authorized access.
  • Genset commissioning can be set to On-load or Off-load mode.
  • Automatic re-closing function for the ATS Controller.
  • Configurable closing output signal as either on intervals or continuous output.
  • Applicable for ATS with one neutral position, two neutral positions, and non-position types.
  • Monitors 1-3 phase AC mains voltages.
  • Manages changeover of both generator and mains contactors.
  • Sends remote start commands to the generating set.
  • Compatible with various contactors and changeover switch types.

3. Kuweka na Kuweka

Proper installation is crucial for the safe and reliable operation of the HAT560NB controller. Ensure all power is disconnected before beginning installation. Refer to the wiring diagrams and terminal descriptions for correct connections.

3.1 Michoro ya Wiring

The HAT560NB controller supports various wiring configurations depending on the ATS type. Below are typical wiring diagrams for different setups. Always consult a qualified electrician for installation.

Multiple wiring diagrams for ATS controllers including ATYS3S, SGQ-N/T, SGQ-M, and VITZRO/PHETENG types

Figure 2: Comprehensive wiring diagrams illustrating connections for ATYS3S, SGQ-N/T, SGQ-M, and VITZRO/PHETENG ATS controller types. These diagrams show connections for 1# and 2# power supplies, load, and remote start signals.

Detailed wiring diagrams for SGQ-N/T, SGQ-M, and Contactor ATS configurations

Figure 3: Additional wiring diagrams focusing on SGQ-N/T, SGQ-M, and Contactor ATS configurations, detailing input and output connections for the controller.

3.2 Connecting Terminals

The controller features clearly labeled terminals for power input, auxiliary outputs, and control signals. Ensure each wire is securely connected to its designated terminal.

Nyuma view of the HAT560NB controller showing labeled connecting terminals for inputs and outputs

Kielelezo cha 4: Nyuma view of the HAT560NB controller, displaying the layout and labeling of all connecting terminals, including power inputs, auxiliary outputs, and communication ports.

4. Maagizo ya Uendeshaji

The HAT560NB controller offers both automatic and manual operation modes, accessible via its front panel buttons and LCD display.

4.1 Power On and Initial Display

Upon powering on, the LCD will display system information, including voltage and frequency readings for both power sources. The backlight ensures visibility in various lighting conditions.

4.2 Uteuzi wa Njia

  • Hali ya Kiotomatiki: The controller automatically monitors the power sources and initiates transfer based on pre-set parameters and detected abnormalities (e.g., over/under voltage, frequency deviations, phase loss).
  • Hali ya Mwongozo: Allows the user to manually control the opening or closing of the transfer switches. This mode is typically used for testing or specific operational requirements.

4.3 Kuweka Kigezo

All operational parameters can be configured directly on the unit using the push-buttons and LCD interface. Access to parameter settings is protected by a two-level password system to prevent unauthorized changes. Refer to the detailed programming guide (not included in this manual) for specific parameter definitions and adjustment procedures.

5. Matengenezo

Regular maintenance ensures the longevity and reliable performance of your HAT560NB ATS Controller.

  • Kusafisha: Keep the controller's exterior clean and free from dust and debris. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
  • Ukaguzi wa Muunganisho: Kagua miunganisho yote ya nyaya mara kwa mara ili kuhakikisha kuwa iko salama na haina kutu. Miunganisho iliyolegea inaweza kusababisha utendakazi wa mara kwa mara au hitilafu za mfumo.
  • Masharti ya Mazingira: Hakikisha mazingira ya uendeshaji yanabaki ndani ya viwango maalum vya halijoto na unyevu ili kuzuia uharibifu wa vipengele vya ndani.

For any internal maintenance or repairs, contact qualified service personnel.

6. Utatuzi wa shida

This section provides guidance on common issues you might encounter with the HAT560NB controller.

TatizoSababu inayowezekanaSuluhisho
Kidhibiti hakiwashiNo DC power supply; Incorrect wiringCheck DC 8.0V-35.0V power supply connections; Verify wiring according to diagrams.
ATS not transferring automaticallyAutomatic mode not selected; Fault detected on active power source (e.g., over/under voltage, frequency); Incorrect parametersEnsure controller is in Automatic mode; Check power source status; Verify parameter settings.
Display shows error for voltage / masafaActual power source issue; Sensor/input wiring problemAngalia juzuu halisitage and frequency of the power source; Inspect AC voltage pembejeo wiring.
Vifungo havijibuTemporary software glitch; Hardware issueRestart the controller by cycling power; If issue persists, contact support.

7. Vipimo

The following table details the technical specifications for the SmartGen HAT560NB ATS Controller.

Table of specifications for SmartGen HAT560N series ATS Controller

Figure 5: Detailed specifications table for the HAT560N series ATS Controller, including operating voltage, power consumption, AC voltage input ranges, rated frequency, relay outputs, communication, dimensions, and environmental conditions.

KipengeeVipimo
Uendeshaji VoltageDC 8.0V-35.0V (continuous power supply)
Voltage PembejeoAC170V-270V (during AC power L1N1/L2N2 supply)
Matumizi ya Nguvu<3W (Hali ya kusubiri: <2W)
Mara kwa mara Iliyokadiriwa50/60Hz
Funga Utoaji wa Relay16A AC250V (Volts free output)
Pato la Usambazaji Msaidizi 17A AC250V (Volts free output)
Pato la Usambazaji Msaidizi 27A AC250V (Volts free output)
Pato la Usambazaji Msaidizi 316A AC250V (Volts free output)
Pato la Usambazaji Msaidizi 416A AC250V (Volts free output)
Uingizaji wa dijitiGND connect is active
MawasilianoKiolesura cha LINK, Itifaki ya MODBUS
Vipimo vya Kesi139mm x 120mm x 48mm (5.47 x 4.72 x inchi 1.89)
Kukatwa kwa Panelimm 130 x 111 mm
Masharti ya KaziTemperature: (-25~+70)°C, Humidity: (20~93)%RH
Hali ya UhifadhiHalijoto: (-25~+70)°C
Kiwango cha UlinziGasket ya IP55
Nguvu ya insulationWeka ujazo wa AC2.2kVtage kati ya ujazo wa juutage terminal na chini voltage terminal; Uvujaji wa sasa sio zaidi ya 3mA ndani ya 1min.
Uzito0.62kg (pauni 1.63)

SmartGen HAT560NB ATS Controller User Manual © 2024. All rights reserved.